Do H. Lim

Do H. Lim

Auto-generated profile, based on publicly available information

Do H. Lim

Department of Neurological Surgery, University of Washington, Seattle, WA, USA

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2023 in Journal of Neurotrauma
Verified
Journal Article
Closed access
AMAnthony J Maxin
Anthony J Maxin
BGBernice G Gulek
Bernice G Gulek
CLChungeun Lee
Chungeun Lee
DLDo Lim
Do Lim
AMAlex Mariakakis
Alex Mariakakis
LMLynn B. McGrath
Lynn B. McGrath
The pupillary light reflex (PLR) is an important biomarker for the detection and management of traumatic brain injury (TBI). We investigated the performance of PupilScreen, a smartphone-based pupillometry app, in classifying healthy control subjects and subjects with severe TBI in comparison to the current gold standard NeurOptics pupillometer (NPi-200 model with proprietary Neurological Pupil Index [NPi] TBI severity score). A total of 230 PLR video recordings taken using both the PupilScreen smartphone pupillometer and NeurOptics handheld device (NPi-200) pupillometer were collected from 33 subjects with severe TBI (sTBI) and 132 subjects who were healthy without self-reported neurological disease. Severe TBI status was determined by Glasgow Coma Scale (GCS) at the time of recording. The proprietary NPi score was collected from the NPi-200 pupillometer for each subject. Seven PLR curve morphological parameters were collected from the PupilScreen app for each subject. A comparison via t-test and via binary classification algorithm performance using NPi scores from the NPi-200 and PLR parameter data from the PupilScreen app was completed. This was used to determine how the frequently used NPi-200 proprietary NPi TBI severity score compares to the PupilScreen app in ability to distinguish between healthy and sTBI subjects. Binary classification models for this task were trained for the diagnosis of healthy or severe TBI using logistic regression, k-nearest neighbors, support vector machine, and random forest machine learning classification models. Overall classification accuracy, sensitivity, specificity, area under the curve, and F1 score values were calculated. Median GCS was 15 for the healthy cohort and 6 (interquartile range 2) for the severe TBI cohort. Smartphone app PLR parameters as well as NPi from the digital infrared pupillometer were significantly different between healthy and severe TBI cohorts; 33% of the study cohort had dark eye colors defined as brown eyes of varying shades. Across all classification models, the top performing PLR parameter combination for classifying subjects as healthy or sTBI for PupilScreen was maximum diameter, constriction velocity, maximum constriction velocity, and dilation velocity with accuracy, sensitivity, specificity, area under the curve (AUC), and F1 score of 87%, 85.9%, 88%, 0.869, and 0.85, respectively, in a random forest model. The proprietary NPi TBI severity score demonstrated greatest AUC value, F1 score, and sensitivity of 0.648, 0.567, and 50.9% respectively using a random forest classifier and greatest overall accuracy and specificity of 67.4% and 92.4% using a logistic regression model in the same classification task on the same dataset. The PupilScreen smartphone pupillometry app demonstrated binary healthy versus severe TBI classification ability greater than that of the NPi-200 proprietary NPi TBI severity score. These results may indicate the potential benefit of future study of this PupilScreen smartphone pupillometry application in comparison to the NPi-200 digital infrared pupillometer across the broader TBI spectrum, as well as in other neurological diseases.

12 December 2024 in Journal of Stroke and Cerebrovascular Diseases
Verified
Journal Article
Open access
AMAnthony J Maxin
Anthony J Maxin
BGBernice G Gulek
Bernice G Gulek
DLDo H. Lim
Do H. Lim
SKSamuel Kim
Samuel Kim
RSRami Shaibani
Rami Shaibani
MLMichael R Levitt
Michael R Levitt
Similarities between acute ischemic and hemorrhagic stroke make diagnosis and triage challenging. We studied a smartphone-based quantitative pupillometer for differentiation of acute ischemic and hemorrhagic stroke. Stroke patients were recruited prior to surgical or interventional treatment. Smartphone pupillometry was used to quantify components of the pupillary light reflex (PLR). A synthetic minority oversampling technique (SMOTE) was applied to correct sample size imbalance. Four binary classification model types were trained using all possible combinations of the PLR components with 10-fold cross validation stratified by cohort. Models were evaluated for accuracy, sensitivity, specificity, area under the curve (AUC), and F1 score. The three best-performing models were selected based on AUC. Shapley additive explanation plots were produced to explain PLR parameter impacts on model predictions. Eleven subjects with intraparenchymal hemorrhage and 22 subjects with acute ischemic stroke were enrolled. One way ANOVA demonstrated significant differences between healthy control data, AIS, and IPH in five out of seven PLR parameters. After SMOTE, each class had n=22 PLR recordings for model training. The best-performing model was random forest using a combination of latency, mean and maximum constriction velocity, and mean dilation velocity to discriminate between stroke types with 91.5% (95% confidence interval: 84.1-98.9) accuracy, 90% (82.9-97.1) sensitivity, 93.3% (83-100) specificity, 0.917 (0.847-0.987) AUC, and 90.7% (84.1-97.3) F1 score. Smartphone-based quantitative pupillometry could be useful in differentiating between acute ischemic and hemorrhagic stroke.

29 December 2023 in Journal of Neurotrauma
Verified
Journal Article
Closed access
AMAnthony J Maxin
Anthony J Maxin
BGBernice G Gulek
Bernice G Gulek
CLChungeun Lee
Chungeun Lee
DLDo Lim
Do Lim
AMAlex Mariakakis
Alex Mariakakis
LMLynn B. McGrath
Lynn B. McGrath
We would like to thank the authors for their interest in our recent manuscript. We agree that the effects of analgesic and sedative administration are among the most relevant complicating factors for the use of any form of pupillometry in the intensive care unit setting. As discussed extensively in the limitations section of our manuscript, a variety of studies have demonstrated the effects of opioid and sedative medications on the pupillary light reflex. To address these concerns, we have performed an additional review of the medication administration records for the patients with severe traumatic brain injury in our study. We reviewed opioid administration prior to pupillometry measurements in our study cohort. In 8 recordings, the last opioid given was hydromorphone. In 21 recordings, the last opioid given was oxycodone. In the remaining 69 recordings, the last opioid given was fentanyl. The median time from most recent opioid administration to pupillary light reflex recording was 1244 minutes (20.7 hours), with an interquartile range of 5484 minutes. Given the long latency period between most recent opioid administration and recording of the pupillary light reflex, their effects on our analysis of the pupillary light reflex are likely minimal.

5 December 2022 in Journal of Biomechanical Engineering
Verified
Journal Article
Closed access
PDF file
DBDavid I. Bass
David I. Bass
LMLaurel M. M. Marsh
Laurel M. M. Marsh
PFPatrick Fillingham
Patrick Fillingham
DLDo Lim
Do Lim
VCV. Keshav Chivukula
V. Keshav Chivukula
MLMichael R Levitt
Michael R Levitt
Successful occlusion of cerebral aneurysms using coil embolization is contingent upon stable thrombus formation, and the quality of the thrombus depends upon the biomechanical environment. The goal of this study was to investigate how coil embolization alters the mechanical micro-environment within the aneurysm dome. Inertialess particles were injected in three-dimensional, computational simulations of flow inside patient aneurysms using patient-specific boundary conditions. Coil embolization was simulated as a homogenous porous medium of known permeability and inertial constant. Lagrangian particle tracking was used to calculate the residence time and shear stress history for particles in the flow before and after treatment. The percentage of particles entering the aneurysm dome correlated with the neck surface area before and after treatment (pretreatment: R2 = 0.831, P < 0.001; post-treatment: R2 = 0.638, P < 0.001). There was an inverse relationship between the change in particles entering the dome and coil packing density (R2 = 0.600, P < 0.001). Following treatment, the particles with the longest residence times tended to remain within the dome even longer while accumulating lower shear stress. A significant correlation was observed between the treatment effect on residence time and the ratio of the neck surface area to porosity (R2 = 0.390, P = 0.007). The results of this study suggest that coil embolization triggers clot formation within the aneurysm dome via a low shear stress-mediated pathway. This hypothesis links independently observed findings from several benchtop and clinical studies, furthering our understanding of this treatment strategy.

13 June 2024 in JMIR Neurotechnology
Verified
Journal Article
Open access
AMAnthony J Maxin
Anthony J Maxin
DLDo H Lim
Do H Lim
SKSophie Kush
Sophie Kush
JCJack Carpenter
Jack Carpenter
RSRami Shaibani
Rami Shaibani
MLMichael R Levitt
Michael R Levitt
Background: Quantitative pupillometry is used in mild traumatic brain injury (mTBI) with changes in pupil reactivity noted after blast injury, chronic mTBI, and sports-related concussion.Objective: We evaluated the diagnostic capabilities of a smartphone-based digital pupillometer to differentiate patients with mTBI in the emergency department from controls.Methods: Adult patients diagnosed with acute mTBI with normal neuroimaging were evaluated in an emergency department within 36 hours of injury (control group: healthy adults). The PupilScreen smartphone pupillometer was used to measure the pupillary light reflex (PLR), and quantitative curve morphological parameters of the PLR were compared between mTBI and healthy controls. To address the class imbalance in our sample, a synthetic minority oversampling technique was applied. All possible combinations of PLR parameters produced by the smartphone pupillometer were then applied as features to 4 binary classification machine learning algorithms: random forest, k-nearest neighbors, support vector machine, and logistic regression. A 10-fold cross-validation technique stratified by cohort was used to produce accuracy, sensitivity, specificity, area under the curve, and F1-score metrics for the classification of mTBI versus healthy participants.Results: Of 12 patients with acute mTBI, 33% (4/12) were female (mean age 54.1, SD 22.2 years), and 58% (7/12) were White with a median Glasgow Coma Scale (GCS) of 15. Of the 132 healthy patients, 67% (88/132) were female, with a mean age of 36 (SD 10.2) years and 64% (84/132) were White with a median GCS of 15. Significant differences were observed in PLR recordings between healthy controls and patients with acute mTBI in the PLR parameters, that are (1) percent change (mean 34%, SD 8.3% vs mean 26%, SD 7.9%; P<.001), (2) minimum pupillary diameter (mean 34.8, SD 6.1 pixels vs mean 29.7, SD 6.1 pixels; P=.004), (3) maximum pupillary diameter (mean 53.6, SD 12.4 pixels vs mean 40.9, SD 11.9 pixels; P<.001), and (4) mean constriction velocity (mean 11.5, SD 5.0 pixels/second vs mean 6.8, SD 3.0 pixels/second; P<.001) between cohorts. After the synthetic minority oversampling technique, both cohorts had a sample size of 132 recordings. The best-performing binary classification model was a random forest model using the PLR parameters of latency, percent change, maximum diameter, minimum diameter, mean constriction velocity, and maximum constriction velocity as features. This model produced an overall accuracy of 93.5%, sensitivity of 96.2%, specificity of 90.9%, area under the curve of 0.936, and F1-score of 93.7% for differentiating between pupillary changes in mTBI and healthy participants. The absolute values are unable to be provided for the performance percentages reported here due to the mechanism of 10-fold cross validation that was used to obtain them.Conclusions: In this pilot study, quantitative smartphone pupillometry demonstrates the potential to be a useful tool in the future diagnosis of acute mTBI.

2 April 2024 in World Neurosurgery
Verified
Journal Article
Closed access
DLDo H. Lim
Do H. Lim
SKSamuel Kim
Samuel Kim
JLJason K. Lim
Jason K. Lim
SSSananthan Sivakanthan
Sananthan Sivakanthan
RMR. Michael Meyer
R. Michael Meyer
BRByeong Cheol Rim
Byeong Cheol Rim