Mars Flaritovich Galautdinov

Mars Flaritovich Galautdinov

Auto-generated profile, based on publicly available information

Mars Flaritovich Galautdinov

Bashkir State Medical University

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 December 2025 in Creative surgery and oncology
Verified
Journal Article
Closed access
ABA. R. Bilyalov
A. R. Bilyalov
SKS. G. Karchevsky
S. G. Karchevsky
ATAndrey Tikhonov
Andrey Tikhonov
MGM. F. Galautdinov
M. F. Galautdinov
VAV. N. Akbashev
V. N. Akbashev
RIR. R. Ishemgulov
R. R. Ishemgulov
Introduction. Additive manufacturing of hydroxyapatite (HA) ceramics is considered a promising approach to creating personalized bone implants. However, highly loaded photopolymer suspensions assume precise composition and exposure conditions to ensure stable printing and product quality. The present study aims to develop a photopolymer suspension based on HA of in-house synthesis for the additive production of ceramic implants using DLP 3D printing. Materials and methods. HA is synthesized by coprecipitation and hydrothermal synthesis methods in aqueous solutions of calcium and phosphate salts. The powder is milled and fractionated for assessing the morphology and element composition using scanning electron microscopy and energy-dispersive X-ray fluorescence analysis, respectively. A photopolymer suspension with 60 wt. % of the inorganic phase, developed based on the synthesized HA, contains acrylate monomers, photoinitiating system and dispersing additives. In addition, photopolymerization is studied on a DLP 3D printer at different UV radiation powers and exposure times. Results and discussion. The synthesized well-crystallized HA has lamellar and nanostructured morphology, as well as developed porosity; the predominance of calcium and phosphorus without significant toxic impurities is confirmed. At a radiation power of 40 mW/cm², the optimal exposure time of 6–10 s ensures the formation of uniformly hardened layers with a thickness of about 0.7–0.9 mm and a thickness plateau at a further increase in exposure time. Conclusion. The obtained data indicate that the combination of controlled HA morphology and specially selected photopolymer matrix provides sufficient polymerization depth and layer stability required for DLP printing of complex geometries. High specific surface area and porosity of HA further enhance its potential in tissue engineering. The developed photopolymer suspension based on HA of in-house synthesis demonstrates suitability for DLP 3D printing and can be used as a basis for creating personalized ceramic implants in traumatology, orthopedics, neurosurgery, and maxillofacial surgery.

12 November 2025 in N.N. Priorov Journal of Traumatology and Orthopedics
Verified
Journal Article
Open access
PDF file
BMBulat Sh. Minasov
Bulat Sh. Minasov
RYRasul R. Yakupov
Rasul R. Yakupov
VAVladislav N. Akbashev
Vladislav N. Akbashev
ABAzat R. Bilyalov
Azat R. Bilyalov
TMTimur B. Minasov
Timur B. Minasov
АААхмельдинова Айгуль Абузаровна
Ахмельдинова Айгуль Абузаровна
BACKGROUND: The increasing number of knee arthroplasty procedures and associated complications underscores the need for the implementation of technologies that enhance the precision of implant component positioning and improve functional outcomes. AIM: This study aimed to assess the precision of robotic knee arthroplasty in comparison with the manual technique based on clinical, radiological, and stabilometric data. METHODS: This cohort-controlled interventional single-center prospective randomized open-label study included 60 patients (aged 18–75 years) with stage III knee osteoarthritis. The patients were randomly assigned to the robotic arthroplasty group (30 individuals) or the manual arthroplasty group (30 individuals). Evaluation was performed 6 months postoperatively using clinical (VAS, ROM), radiological (LDFA, MPTA, rotational parameters), and stabilometric indicators. High-precision scales and 3D modeling were used to analyze the mass of the cement mantle. RESULTS: The robotic technique demonstrated superiority in the precision of component positioning: deviations of less than 1° in LDFA and MPTA were recorded in 93% and 66% of patients, respectively (compared with 23% and 9.4% in the manual technique group). The mean range of motion was 109° versus 106.2°, and the VAS pain score was 3.7 versus 4.2. The robotic technique ensured lower variability in cement mass and cement mantle thickness. CONCLUSION: Robotic arthroplasty surpasses the manual technique in terms of component positioning precision, cement mass distribution, and functional outcomes. Despite the absence of statistically significant differences (p 0.05), the observed trends in favor of the robotic approach render it preferable for widespread clinical application.

16 April 2024 in ZHurnal «Patologicheskaia fiziologiia i eksperimental`naia terapiia»
Verified
Journal Article
Open access
PDF file
ALAnna Lebedeva
Anna Lebedeva
ЕГЕвгений Мусинович Гареев
Евгений Мусинович Гареев
АДАйгуль Маратовна Дусалимова
Айгуль Маратовна Дусалимова
РКРадик Завилович Кадыров
Радик Завилович Кадыров
ЛМЛяля Ахияровна Мусина
Ляля Ахияровна Мусина
ИТИльдар Ильшатович Терегулов
Ильдар Ильшатович Терегулов
Введение. Вынужденная физическая нагрузка часто нарушает слаженность взаимодействий между корой головного мозга и внутренними органами. Аллогенный биоматериал (БМА) применяется в качестве стимулятора регенерации при его местном применении. Механизм фармакупунктурной коррекции патологических изменений посредством БМА в неокортексе изучен недостаточно. Цель исследования – изучение структуры нервной ткани коры головного мозга в условиях акупунктурного воздействия на биологически активные точки и фармакупунктурной коррекции с БМА. Методика. Моделью анаэробной физической нагрузки явилось принудительное плавание крыс самцов с грузом 10% от массы тела. После проведения плавательного теста в опытной группе (n=20) вводили суспензию БМА акупунктурно, в контрольной (n=20) вводили физиологический раствор. Материал для морфофункционального исследования брали через 5 и 21 сут после принудительной анаэробной физической нагрузки. Результаты. В контрольной группе обнаруживался реактивный глиоз, отек нейропиля, перинуклеарных и периваскулярных пространств, редукция синаптического аппарата, усиление хроматолиза нейроцитов, снижение уровня ингибитора апоптоза Bcl-2+ в клетках. В опытной группе наблюдались признаки восстановления архитектоники слоев нервных клеток неокортекса, увеличения численности синапсов, микроглиальных клеток (CD-68+), Bcl-2+ клеток, снижение количества клеток теней и GFAP+ клеток, восстановление нейроваскулярной единицы, обеспечивающей работу гематоэнцефалического барьера. Заключение. В контрольной группе происходили деструктивные изменения необратимого характера. Акупунктурное воздействие БМА стимулировало нейропротекторные свойства. Introduction. Forced physical activity often disrupts the interactions between the cerebral cortex and internal organs. Allogeneic biomaterial (BMA) is used as a regeneration stimulator when applied topically. The mechanism of pharmacopuncture correction of pathological changes in the neocortex with BMA is not well understood. Aim. To study the structure of nervous tissue in the cerebral cortex after acupuncture of biologically active points and pharma-copuncture administration of BMA. Methods. Anaerobic physical activity was modeled by forced swimming of male rats with a load of 10% of body weight. After the swimming test, in the experimental group (n=20), a BMA suspension was administered by acupuncture. In the control group (n=20), saline was administered. Five and 21 days following the forced anaerobic exercise, tissue was sampled, and morpho-functional studies were performed. Results. In the control group, reactive gliosis, edema of the neuropil, perinuclear and perivascular spaces, reduction of the synaptic apparatus, increased chromatolysis of neurocytes, and a decrease in the apoptosis inhibitor Bcl-2+ in cells were found. In the experimental group, there were signs of restoration of the architectonics of the layers of neocortical nerve cells, an increase in the number of synapses, microglial cells (CD-68+), cell Bcl-2+, a decrease in the number of shadow cells and cell GFAP+, and restoration of the neurovascular unit that ensures the blood-brain barrier functioning. Conclusion. In the brain of control rats, irreversible destructive changes prevailed. Acupuncture of BMA stimulated neuroprotection.

24 December 2025 in Creative surgery and oncology
Verified
Journal Article
Closed access
ABA. R. Bilyalov
A. R. Bilyalov
ABA. T. Bikmeev
A. T. Bikmeev
Iskander AkhatovIskander Akhatov
Iskander Akhatov
DDDmitriy Dzhurinskiy
Dmitriy Dzhurinskiy
RYR. S. Yurovskikh
R. S. Yurovskikh
MGM. F. Galautdinov
M. F. Galautdinov
The risk of developing postoperative complications directly depends on the biocompatibility of implant systems, which is largely determined by the condition and properties of their surface. Hydroxyapatite (HA) coatings are characterized by maximum similarity of structural and functional properties to those of bone tissue, which determines their wide application in biomedical engineering. Therefore, HA as a modifying surface coating can significantly increase the biocompatibility of implants and activate osseointegration processes. Today, thin HA coatings are mainly applied using thermal spraying methods at temperatures close to the melting point of the original material. However, exposure to high temperatures decreases the biocompatibility of the final coating and limits the introduction of heat-labile bioactive additives into its composition. In this regard, cold spraying technologies represent a promising direction, potentially superior to standard thermal methods. However, high brittleness of HA significantly complicates the low-temperature application of strong and uniform coatings. Thus, the selection of an optimal technological approach and establishment of rational spraying parameters represent key conditions for the formation of coatings with the required physicochemical characteristics increasing the efficiency of osseointegration. This paper presents a systematic analysis of experimental studies aimed at developing a conceptual framework for selecting powder, substrate and cold spraying parameters aimed at obtaining high-quality HA coatings with improved biomedical properties.

21 January 2025 in Journal of Anatomy and Histopathology
Verified
Journal Article
Open access
PDF file
MKM. Yu. Klyavlina
M. Yu. Klyavlina
AMA. V. Maslennikov
A. V. Maslennikov
DRD. Yu. Rybalko
D. Yu. Rybalko
MGM. F. Galautdinov
M. F. Galautdinov
FKF. F. Kil'MUkhametov
F. F. Kil'MUkhametov
МКМ. Ю. Клявлина
М. Ю. Клявлина
The aim was to create a three-dimensional model of the umbilical cord vessels of newborns, taking into account their individual morphometric features and evaluation the compliance of the morphometric parameters of the 3D model and the corrosion preparation. Material and methods. The material for the study included the umbilical cord vessels of full-term newborns whose status at birth was estimated at ≥7 points on the Apgar scale, in the amount of 20 samples, 10 cm long. The first stage of the study was the production of corrosion preparations based on the dental material “Belakril”-M XO. Then the corrosion preparations were scanned on a 3D scanner RangeVision SPECTRUM (Russia) on a rotary table at a speed of 24°/s. As a result, 3D models of umbilical cord vessels were obtained in the ScanCenter NG 2022 program.The number of turns in a given area was counted, the distance between the turns of the umbilical cord vessels was measured on corrosion preparations using an electronic caliper, the distance between the “artery and vein” complexes, the circumference of the umbilical cord vessel complex was measured with a centimeter tape, and the internal diameter of the arteries and veins was measured with a micrometer. Measurements of 3D models were taken in the Blender 4.2. STL program. Statistical data processing was carried out in the Statistica 10 program. Results. On the corrosion specimen and 3D model, the number of turns on the examined section of the umbilical cord with a length of 10 cm did not exceed two. The distance between the turns was 45 mm. The distance between adjacent “artery and vein” complexes was 45 mm. The internal diameter of the arteries and veins was 2.6 mm and 7.3 mm, respectively. Comparison of the morphometric parameters of the corrosion preparation and the 3D model showed no statistically significant differences. This observation may indicate the methodological accuracy and adequacy of the technology for constructing 3D models from the corrosion preparation. Conclusion. The morphometric parameters of computer 3D models of the umbilical cord vessels of full-term newborns created using the RangeVision SPECTRUM 3D scanner are identical to those of corrosive preparations. Such models can be used in the future as a basis for setting up biophysical experiments and for creating computer simulations.