Waqas Ali

Waqas Ali

Auto-generated profile, based on publicly available information

Waqas Ali

Department of Electrical Engineering (RCET), University of Engineering and Technology, Lahore, PAKISTAN

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 June 2025 in IEEE Access
Verified
Journal Article
Open access
UAUsman Ali
Usman Ali
URUmer Ramzan
Umer Ramzan
WAWaqas Ali
Waqas Ali
Khaled Ali Al JaafariKhaled Ali Al Jaafari
Khaled Ali Al Jaafari
Early detection of faults in induction motors is crucial for ensuring uninterrupted operations in industrial settings. Among the various fault types encountered in induction motors, bearing, rotor, and stator faults are the most prevalent. This paper introduces a Weighted Probability Ensemble Deep Learning (WPEDL) methodology, tailored for effectively diagnosing induction motor faults using high-dimensional data extracted from vibration and current features. The Short-Time Fourier Transform (STFT) extracts features from vibration and current signals. The performance of the WPEDL fault diagnosis method is compared against conventional deep learning models, demonstrating the superior efficacy of the proposed system. The multi-class fault diagnosis system based on WPEDL achieves high accuracies across different fault types: 99.05% for bearing (vibrational signal), 99.10%, and 99.50% for rotor (current and vibration signal), and 99.60%, and 99.52% for stator faults (current and vibration signal) respectively. To evaluate the robustness of our multi-class classification decisions, tests have been conducted on a combined dataset of 52,000 STFT images encompassing all three faults. Our proposed model outperforms other models, achieving an accuracy of 98.89%. The findings underscore the effectiveness and reliability of the WPEDL approach for early-stage fault diagnosis in IMs, offering promising insights for enhancing industrial operational efficiency and reliability.

12 January 2026 in IEEE Sensors Journal
Verified
Journal Article
Closed access
UAUsman Ali
Usman Ali
AZAli Zia
Ali Zia
WAWaqas Ali
Waqas Ali
URUmer Ramzan
Umer Ramzan
ARAbdul Rehman
Abdul Rehman
Wei XiangWei Xiang
Wei Xiang
Reliable induction motor (IM) fault diagnosis is vital for industrial safety and operational continuity, mitigating costly unplanned downtime. Conventional approaches often struggle to capture complex multimodal signal relationships, are constrained to unimodal data or single fault types, and degrade under noise or cross-domain shifts. We propose the multimodal hypergraph contrastive attention network (MM-HCAN), a unified framework that integrates multihead attention with a hypergraph architecture and contrastive learning (CL) to jointly model global and localized intra- and inter-modal dependencies beyond Euclidean embedding spaces. MM-HCAN’s gains are driven by three innovations: 1) a structured multimodal fusion scheme with dynamically constructed hyperedges encoding higher order cross-modal relationships; 2) modality-specific hypergraph Laplacians for fine-grained, context-aware embedding refinement; and 3) triplet-based CL performed directly on the hypergraph manifold, yielding more discriminative, topologyrespecting representations. The model enables simultaneous diagnosis of bearing, stator, and rotor faults, addressing the engineering need for consolidated diagnostics. Evaluated on three real-world benchmarks, MM-HCAN achieves up to 99.82% accuracy with strong cross-domain generalization and robustness to noise. An ablation study confirms the contribution of each component. MM-HCAN offers a scalable and robust solution for comprehensive multifault diagnosis, supporting predictive maintenance and extended asset longevity in industrial environments. Code is available at https://github.com/EngrUsmaanAli/MM-HCAN

28 January 2021 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
WAWaqas Ali
Waqas Ali
HFHaroon Farooq
Haroon Farooq
ARAkhtar Rasool
Akhtar Rasool
ISIntisar Ali Sajjad
Intisar Ali Sajjad
CZCui Zhenhua
Cui Zhenhua
LNLin Ning
Lin Ning
This paper models and analyses the dynamic response of a synchronous generator driven off-grid micro hydro power system using Simulink tool of MATLAB software. The results are assessed from various perspectives including regulation through no load to full load and overload scenarios under normal and abnormal operating conditions. The investigation under the normal conditions of no load, linearly changing load and full load divulges that the system operates in a satisfactory manner as generator voltage and frequency remain approximately constant at 1 pu. However, at full load generator voltage and frequency drop 3% and 0.5% respectively from its nominal values but remain within prescribed standard IEC limits. The results also expose that the abnormal conditions produced by abrupt changes in load, system faults and severe overload, cause the unwonted variations in the magnitude of generator parameters. Moreover, the study reveals that the system stability significantly enhances when the system is run at full load because the regulation time to fix the variations in the generator parameters; except input mechanical power; decreases, e.g. from 4.1 sec to 0.8 sec for generator voltage, with the increase in the loading from quarter to full load respectively at unity power factor. Further, it is also observed that the regulation time rises, e.g. from 0.8 sec to 1.3 sec for generator voltage, with the reduction in load power factor from unity to 0.8, respectively. Thus, proper protection, to cater for increased fault current at full load and power factor correction must be provided to improve the system stability and protection. Furthermore, it is also concluded that the over loading in any case should be strongly avoided in this type of system and it should never be allowed to exceed 20% of the full load value to avoid system failure

13 October 2021
Verified
Conference Paper
Closed access
VKVishal K A Kushalappa
Vishal K A Kushalappa
IEIbrahim Elsabrouty
Ibrahim Elsabrouty
WAWaqas Ali
Waqas Ali
ICIlknur Colak
Ilknur Colak
This paper presents an implementation methodology to model a single delta bridge cell (full-bridge) modular multilevel converter static synchronous compensator (SDBC-MMC-STATCOM) in FPGA based real-time simulator. Mathematical modeling of full-bridge submodule and equivalent circuit-based modeling of single delta bridge cell modular multilevel converter is presented. This paper also discusses about different discretization strategies to convert continuous time equations into z-domain equations for implementation in field programmable gate array (FPGA). The discretized equations are verified by comparing its voltage and current waveforms with its equivalent model developed using the Simscape Electrical Specialized Power Systems library in Simulink. The testing is carried out with 4kV, 2MVA STATCOM model with phase-shifted carrier-based modulation. The model is then implemented in FPGA to perform real-time simulation in OPAL-RT real -time simulator. The tests verify that the real-time model of the STATCOM behaves similar to the Simulink reference model for positive sequence reactive power compensation with no voltage unbalance at the point of common coupling (PCC).

19 November 2020 in International Journal of Renewable Energy Development
Verified
Journal Article
Open access
PDF file
WAWaqas Ali
Waqas Ali
HFHaroon Farooq
Haroon Farooq
ARAkhtar Rasool
Akhtar Rasool
ISIntisar Ali Sajjad
Intisar Ali Sajjad
CZCui Zhenhua
Cui Zhenhua
LNLin Ning
Lin Ning
This paper models and analyses the dynamic response of a synchronous generator driven off-grid micro hydro power system using Simulink tool of MATLAB software. The results are assessed from various perspectives including regulation through no load to full load and overload scenarios under normal and abnormal operating conditions. The investigation under the normal conditions of no load, linearly changing load and full load divulges that the system operates in a satisfactory manner as generator voltage and frequency remain approximately constant at 1 pu. However, at full load generator voltage and frequency drop 3% and 0.5% respectively from its nominal values but remain within prescribed standard IEC limits. The results also expose that the abnormal conditions produced by abrupt changes in load, system faults and severe overload, cause the unwonted variations in the magnitude of generator parameters. Moreover, the study reveals that the system stability significantly enhances when the system is run at full load because the regulation time to fix the variations in the generator parameters; except input mechanical power; decreases, e.g. from 4.1 sec to 0.8 sec for generator voltage, with the increase in the loading from quarter to full load respectively at unity power factor. Further, it is also observed that the regulation time rises, e.g. from 0.8 sec to 1.3 sec for generator voltage, with the reduction in load power factor from unity to 0.8, respectively. Thus, proper protection, to cater for increased fault current at full load and power factor correction must be provided to improve the system stability and protection. Furthermore, it is also concluded that the over loading in any case should be strongly avoided in this type of system and it should never be allowed to exceed 20% of the full load value to avoid system failure

29 October 2023
Verified
Conference Paper
Closed access
WAWaqas Ali
Waqas Ali
ABAra Bissal
Ara Bissal
MMMartin März
Martin März
Hybrid direct current (DC) breakers are essential for fast fault current interruption in low voltage direct current (LVDC) systems. This study investigates the current interruption capabilities of a hybrid DC breaker’s solid-state branch by using a programmable flyback power supply to generate different gate voltages. The results demonstrate that a single discrete insulated gate bipolar transistor (IGBT) in a TO-264 package can interrupt 1300 A by increasing the gate voltage from 16 V to 30 V, 12 times its rated value. By connecting four of these IGBTs in parallel with a symmetric layout, equal current sharing is achieved, allowing currents up to 4000 A to be successfully interrupted. These findings pave the way for small, efficient, cost-effective hybrid DC breakers that do not require expensive IGBT modules.