Lina Mekki

Lina Mekki

Auto-generated profile, based on publicly available information

Lina Mekki

Department of Biomedical Engineering, Johns Hopkins University, 720 Rutland Ave, Baltimore, Maryland, 21205, UNITED STATES

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 October 2023 in Physics in Medicine & Biology
Verified
Journal Article
Open access
LML Mekki
L Mekki
NSN M Sheth
N M Sheth
RVR C Vijayan
R C Vijayan
MRM Rohleder
M Rohleder
ASA Sisniega
A Sisniega
AUAli Uneri
Ali Uneri
Objective . Surgical guidewires are commonly used in placing fixation implants to stabilize fractures. Accurate positioning of these instruments is challenged by difficulties in 3D reckoning from 2D fluoroscopy. This work aims to enhance the accuracy and reduce exposure times by providing 3D navigation for guidewire placement from as little as two fluoroscopic images. Approach . Our approach combines machine learning-based segmentation with the geometric model of the imager to determine the 3D poses of guidewires. Instrument tips are encoded as individual keypoints, and the segmentation masks are processed to estimate the trajectory. Correspondence between detections in multiple views is established using the pre-calibrated system geometry, and the corresponding features are backprojected to obtain the 3D pose. Guidewire 3D directions were computed using both an analytical and an optimization-based method. The complete approach was evaluated in cadaveric specimens with respect to potential confounding effects from the imaging geometry and radiographic scene clutter due to other instruments. Main results . The detection network identified the guidewire tips within 2.2 mm and guidewire directions within 1.1°, in 2D detector coordinates. Feature correspondence rejected false detections, particularly in images with other instruments, to achieve 83% precision and 90% recall. Estimating the 3D direction via numerical optimization showed added robustness to guidewires aligned with the gantry rotation plane. Guidewire tips and directions were localized in 3D world coordinates with a median accuracy of 1.8 mm and 2.7°, respectively. Significance . The paper reports a new method for automatic 2D detection and 3D localization of guidewires from pairs of fluoroscopic images. Localized guidewires can be virtually overlaid on the patient’s pre-operative 3D scan during the intervention. Accurate pose determination for multiple guidewires from two images offers to reduce radiation dose by minimizing the need for repeated imaging and provides quantitative feedback prior to implant placement.

7 November 2025 in Physics in Medicine & Biology
Verified
Journal Article
Open access
LMLina Mekki
Lina Mekki
WHWilliam T Hrinivich
William T Hrinivich
JLJunghoon Lee
Junghoon Lee
Objective. To develop and evaluate a deep reinforcement learning (RL) framework for rapid and automatic machine parameter optimization of volumetric modulated arc therapy (VMAT) treatment plans for localized prostate cancer. Approach. A multi-task policy network combining convolution and long short-term memory was trained to sequentially predict the set of actions on the dose rate and multi-leaf collimator positions over the range of two arcs. The network uses as input the cumulative dose grid at the current gantry angle, contours of the planning target volume (PTV) and organs at risk, and the set of machine parameters at all preceding gantry angles. The method was evaluated on a set of 15 localized prostate cancer patients for a prescription dose of 60 Gy in 20 fractions. For each case, the final state dose distribution was compared against clinical plans. For seamless integration with the clinical workflow, the proposed model was integrated into a clinical treatment planning system (TPS), enabling dosimetric review and final plan adjustments. Main results. The RL framework produced deliverable dual-arc VMAT plans in an average of 20.7 ± 5.0 s over the test set. Dosimetric comparison to clinical plans showed no statistically significant differences for the mean rectum dose as well as for the bladder V6160 Gy, indicating that the RL model was as efficient in sparing these structures as human planners. While the approach showed limitations in terms of PTV coverage and maximum body dose, our proposed integration to TPS showed the RL plans could be automatically refined to clinical quality in an additional 83.8 ± 7.2 s. Significance. The accuracy and fast run time of the approach show the potential of the framework to significantly streamline VMAT treatment planning and enable adaptive radiation therapy.