1 February 2018 in Journal of Cardiovascular Magnetic Resonance
Real-time cardiovascular magnetic resonance (CMR) assessment of ventricular volumes and function enables data acquisition during free-breathing. The requirement for high spatiotemporal resolution in children necessitates the use of highly accelerated imaging techniques. A novel real-time balanced steady state free precession (bSSFP) spiral sequence reconstructed using Compressed Sensing (CS) was prospectively validated against the breath-hold clinical standard for assessment of ventricular volumes in 60 children with congenital heart disease. Qualitative image scoring, quantitative image quality, as well as evaluation of biventricular volumes was performed. Standard BH and real-time measures were compared using the paired t-test and agreement for volumetric measures were evaluated using Bland Altman analysis. Acquisition time for the entire short axis stack (~ 13 slices) using the spiral real-time technique was ~ 20 s, compared to ~ 348 s for the standard breath hold technique. Qualitative scores reflected more residual aliasing artefact (p < 0.001) and lower edge definition (p < 0.001) in spiral real-time images than standard breath hold images, with lower quantitative edge sharpness and estimates of image contrast (p < 0.001). There was a small but statistically significant (p < 0.05) overestimation of left ventricular (LV) end-systolic volume (1.0 ± 3.5 mL), and underestimation of LV end-diastolic volume (− 1.7 ± 4.6 mL), LV stroke volume (− 2.6 ± 4.8 mL) and LV ejection fraction (− 1.5 ± 3.0%) using the real-time technique. We also observed a small underestimation of right ventricular stroke volume (− 1.8 ± 4.9 mL) and ejection fraction (− 1.4 ± 3.7%) using the real-time imaging technique. No difference in inter-observer or intra-observer variability were observed between the BH and real-time sequences. Real-time bSSFP imaging using spiral trajectories combined with a compressed sensing reconstruction showed good agreement for quantification of biventricular metrics in children with heart disease, despite slightly lower image quality. This technique holds the potential for free breathing data acquisition, with significantly shorter scan times in children.
8 November 2019 in Magnetic Resonance in Medicine
Purpose: we implemented a golden‐angle spiral phase contrast sequence. A commonly used uniform density spiral and a new ‘perturbed’ spiral that produces more incoherent aliases were assessed. The aim was to ascertain whether greater incoherence enabled more accurate Compressive Sensing reconstruction and superior measurement of flow and velocity.Methods: A range of ‘perturbed’ spiral trajectories based on a uniform spiral trajectory were formulated. The trajectory that produced the most noise‐like aliases was selected for further testing. For in‐silico and in‐vivo experiments, data was reconstructed using total Variation L1 regularisation in the spatial and temporal domains. In‐silico, the reconstruction accuracy of the ‘perturbed’ golden spiral was compared to uniform density golden‐angle spiral. For the in‐vivo experiment, stroke volume and peak mean velocity were measured in 20 children using ‘perturbed’ and uniform density golden‐angle spiral sequences. These were compared to a reference standard gated Cartesian sequence.Results: In‐silico, the perturbed spiral acquisition produced more accurate reconstructions with less temporal blurring (NRMSE ranging from 0.03 to 0.05) than the uniform density acquisition (NRMSE ranging from 0.06 to 0.12). This translated in more accurate results in‐vivo with no significant bias in the peak mean velocity (bias: −0.1, limits: −4.4 to 4.1 cm/s;P= 0.98) or stroke volume (bias: −1.8, limits: −9.4 to 5.8 ml,P= 0.19).Conclusion: We showed that a ‘perturbed’ golden‐angle spiral approach is better suited to Compressive Sensing reconstruction due to more incoherent aliases. This enabled accurate real‐time measurement of flow and peak velocity in children.
7 September 2023 in Magnetic Resonance in Medicine
Purpose: MR‐guided cardiac catheterization procedures currently use passive tracking approaches to follow a gadolinium‐filled catheter balloon during catheter navigation. This requires frequent manual tracking and repositioning of the imaging slice during navigation. In this study, a novel framework for automatic real‐time catheter tracking during MR‐guided cardiac catheterization is presented.Methods: The proposed framework includes two imaging modes (Calibration and Runtime). The sequence starts in Calibration mode, in which the 3D catheter coordinates are determined using a stack of 10–20 contiguous saturated slices combined with real‐time image processing. The sequence then automatically switches to Runtime mode, where three contiguous slices (acquired with partial saturation), initially centered on the catheter balloon using the Calibration feedback, are acquired continuously. The 3D catheter balloon coordinates are estimated in real time from each Runtime slice stack using image processing. Each Runtime stack is repositioned to maintain the catheter balloon in the central slice based on the prior Runtime feedback. The sequence switches back to Calibration mode if the catheter is not detected. This framework was evaluated in a heart phantom and 3 patients undergoing MR‐guided cardiac catheterization. Catheter detection accuracy and rate of catheter visibility were evaluated.Results: The automatic detection accuracy for the catheter balloon during the Calibration/Runtime mode was 100%/95% in phantom and 100%/97 ± 3% in patients. During Runtime, the catheter was visible in 82% and 98 ± 2% of the real‐time measurements in the phantom and patients, respectively.Conclusion: The proposed framework enabled real‐time continuous automatic tracking of a gadolinium‐filled catheter balloon during MR‐guided cardiac catheterization.
1 February 2018 in Journal of Cardiovascular Magnetic Resonance
Children with chronic kidney disease (CKD) have increased cardiovascular mortality. Identifying high-risk children who may benefit from further therapeutic intervention is difficult as cardiovascular abnormalities are subtle. Although transthoracic echocardiography may be used to detect sub-clinical abnormalities, it has well-known problems with reproducibility that limit its ability to accurately detect these changes. Cardiovascular magnetic resonance (CMR) is the reference standard method for assessing blood flow, cardiac structure and function. Furthermore, recent innovations enable the assessment of radial and longitudinal myocardial velocity, such that detection of sub-clinical changes is now possible. Thus, CMR may be ideal for cardiovascular assessment in pediatric CKD. This study aims to comprehensively assess cardiovascular function in pediatric CKD using CMR and determine its relationship with CKD severity. A total of 120 children (40 mild, 40 moderate, 20 severe pre-dialysis CKD subjects and 20 healthy controls) underwent CMR with non-invasive blood pressure (BP) measurements. Cardiovascular parameters measured included systemic vascular resistance (SVR), total arterial compliance (TAC), left ventricular (LV) structure, ejection fraction (EF), cardiac timings, radial and longitudinal systolic and diastolic myocardial velocities. Between group comparisons and regression modelling were used to identify abnormalities in CKD and determine the effects of renal severity on myocardial function. The elevation in mean BP in CKD was accompanied by significantly increased afterload (SVR), without evidence of arterial stiffness (TAC) or increased fluid overload. Left ventricular volumes and global function were not abnormal in CKD. However, there was evidence of LV remodelling, prolongation of isovolumic relaxation time and reduced systolic and diastolic myocardial velocities. Abnormal cardiovascular function is evident in pre-dialysis pediatric CKD. Novel CMR biomarkers may be useful for the detection of subtle abnormalities in this population. Further studies are needed to determine to prognostic value of these biomarkers.
1 October 2020 in Magnetic Resonance Imaging
1 August 2014 in Concurrency and Computation: Practice and Experience