Ji Qiao

Ji Qiao

Auto-generated profile, based on publicly available information

Ji Qiao

Department of Electrical Engineering, Beijing China 100084

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2015 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
JQJi Qiao
Ji Qiao
JZJun Zou
Jun Zou
BLBenliang Li
Benliang Li
The electric field and ion current distribution on the ground level and corona losses are the important factors for designing high‐voltage direct current (HVDC) transmission lines. This study presents a new finite‐difference‐based flux tracing (FDFT) method for analysing the ionised field. The differential equations are discretised using the finite‐difference method and the non‐linear algebraic equations are constructed. For the bipolar field, a systematic technique to set up the initial values is well established by estimating the average values of space charge density. The issues of the finite‐difference scheme, the normalisation and the selection of mesh points are elaborately discussed to have a better convergence. The boundary conditions of the ionised field equations can be enforced directly, whose benefit is that the iterative process to satisfy the boundary conditions can be completely avoided. The numerical examples show that the results obtained in this study agree well with the ones published in other literatures. The FDFT could be applied for more complicated line configuration with unequal corona‐onset electric fields and ion mobilities of opposite polarities.

30 October 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
JQJi Qiao
Ji Qiao
JZJun Zou
Jun Zou
JZJiangong Zhang
Jiangong Zhang
YLYao Lu
Yao Lu
JLJaebook Lee
Jaebook Lee
MJMun-No Ju
Mun-No Ju
Building HVDC and HVAC transmission lines in the same corridor or even on the same tower is an attractive way to extend electricity transport capacity where getting the new right of way is difficult. The resulting hybrid lines produce a new corona performance, such as ground-level hybrid electric field and ion current density, which are quite different from those of pure AC or DC lines. In this paper, inherent space-time pattern and characteristics of the information propagation in Lagrangian description are presented for the ion transport problem, i.e., the ion density at a certain point has a direct relationship with its drift time. Based on this, the theoretical explanation is provided for the decoupling algorithm, by which the ground-level DC component can be solved with the AC conductors assumed to be at zero potential and vice versa. The simulation results show that the sinusoidal AC field has negligible influence on the DC ion drift time from conductor surface to ground while stationary electric field generated by the grounded AC lines has a dominant effect. Therefore AC energization has rather low impact on ground-level quantities and the simplification of grounded AC conductors is quite reasonable.

1 March 2017 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
JQJi Qiao
Ji Qiao
JZJun Zou
Jun Zou
JYJiansheng Yuan
Jiansheng Yuan
JLJaebok Lee
Jaebok Lee
MJMun‐No Ju
Mun‐No Ju
The electric field and ion flow are significantly influenced by the transverse wind around the high‐voltage direct current (HVDC) transmission lines. In this study, a new method using local characteristics is proposed to analyse the effect of wind. The present method, called method of local characteristic, updates the ion density based on the local characteristic curve in each second‐order finite element method (FEM) element without Deutsch assumption. The defining equation of the characteristics is able to take into account the directional character of the information propagation in convective transport and has a better performance to satisfy the conservation law. The present approach is stable and efficient even in the presence of high‐speed transverse wind. Calculations show good agreement with the measurement values of the reduced‐scale unipolar model and the full‐scale bipolar test line. Finally, the influence of wind on the electric field and ion current is discussed.