Fibre-reinforced concrete, if properly designed, can be a very efficient construction material. However, there are challenges to using them in load-bearing structures due to the high dispersion of strength properties. Therefore, structural design methods need to be calibrated with experimental data. This research aims to investigate factors that influence the shear capacity of steel fibre-reinforced concrete (SFRC) beams with conventional longitudinal reinforcement (Hybrid reinforcement). An experimental test program of 30 large beam specimens, 96 prism specimens, 45 cores, and 15 cubes was conducted. Beams were tested in a three-point bending configuration resulting in a shear failure. Additionally, the crack propagation and crack width were examined. Two types of fibres were used with diameter of 0.5 mm and length of 50 mm and 35 mm. The fibres at volume fractions of 40 kg m-³ and 80 kg m-³ were tested and compared with the specimens that were without steel fibres. Tools like a digital image correlation (DIC) were employed to monitor the crack propagation, and a web plot designer was utilized to analyse the fibre count. The results demonstrate that the fibres contributed up to 120% for the increase of shear capacity with fibre dosage of 40 kg/m³, and up to 220% when the dosage was 80 kg m-³. Beams with long fibres (50 mm) showed more abrupt failure caused by rupture of fibres. The results of the current study reveal that there are phenomena that cannot be captured based on the standard prism tests. These results are going to be used to calibrate numerical models in nonlinear models in non-linear finite element analysis software in future studies.