Ulvis Skadiņš

Dr. Ulvis Skadiņš

Latvia University of Life Sciences and Technologies, Jelgava, Jelgavas Novads, Latvia
+1
orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 February 2023 in Fibers
Verified
Journal Article
Open access
PDF file
Ulvis SkadiņšUlvis Skadiņš
Ulvis Skadiņš
KKKristens Kuļevskis
Kristens Kuļevskis
AVAndris Vulāns
Andris Vulāns
RBRaitis Brencis
Raitis Brencis
In this study, structural thin-layer sandwich walls (SWs) made of steel-fibre-reinforced concrete (SFRC) without conventional reinforcements were investigated. Other researchers have shown that SWs with thin wythes can be used as load bearing structures in low-rise buildings, thereby reducing the amount of concrete by 2–5 times if compared to conventional reinforced-concrete SWs. In most studies, relatively warm climatic regions are the focus, and thin-layer SWs with shear connectors to obtain a certain level of composite action are investigated. In almost no studies has sound insulation been evaluated. In this study, a numerical investigation of structural, thermal and sound insulation performances was carried out. The load-bearing capacities of composite and non-composite SWs are compared. Regions with the lowest five-day mean air temperature of −20 ∘C were considered. The characteristics of the SW are compared to the requirements given in relevant European and Latvian standards. The minimum thermal insulation for family houses varies from 120 mm to 200 mm, depending on the material. To ensure sufficient sound insulation, the average thickness of the concrete wythes should be around 60 mm, preferably with a 15 mm difference between them. Structural analysis of the proposed wall panel was performed using non-linear finite element analysis software ATENA Science. The obtained load-bearing capacity exceeded the design loads of a single-story family house by around 100 times, regardless of the degree of composite action.

12 September 2024
Verified
Book Chapter
Closed access
PDF file
Ulvis SkadiņšUlvis Skadiņš
Ulvis Skadiņš
MSMartins Suta
Martins Suta
GFGregor Fischer
Gregor Fischer
ADAtis Dandens
Atis Dandens

1 December 2020 in IOP Conference Series: Materials Science and Engineering
Verified
Conference Paper
Open access
PDF file
Ulvis SkadiņšUlvis Skadiņš
Ulvis Skadiņš
ADAtis Dandens
Atis Dandens
Precast concrete slabs and their supporting walls are connected using dowel pins, anchoring loop bars, and cast-in-situ concrete. The design resistance of such connections can be calculated using multiple different methods. The design load bearing capacity can vary depending on the method used and assumptions made during calculation, making it difficult to determine, which methods are reliable and should be preferred. The study ordered by construction company JSC “UPB” discusses two design methods proposed by Eurocode 2 and fib Bulletin 43. A semi full-scale loading tests of concrete walls and slab specimens are carried out. The results show that the design methods considering only the contribution of steel dowel pins, underestimates the actual capacity of the connection by 2 to 4 times. On the other hand, the methods, considering both the contribution of the dowels and the friction between concrete interfaces, correspond well with the experimental results.

28 June 2022 in Preprints.org
Verified
Preprint
Open access
PDF file
Ulvis SkadiņšUlvis Skadiņš
Ulvis Skadiņš
Steel fibres provides ductility to concrete structures. This in turn gives possibility to replace or reduce conventional reinforcement in structural elements. In this study the focus is on structural walls and the fibres as potential replacement for horizontal reinforcement in areas where vertical re-bars are needed. An experimental study was conducted, in which prismatic specimens with longitudinal re-bars were subjected to centric loading. Ten samples with 12 specimens in each were tested. The parameters considered were: fibre content, concrete cover for the longitudinal bars, and presence of stirrups. Self-compacting concrete with 30 and 60 kg/m3 steel fibres was used. The influence of fibres on maximum load, stiffness, and ductility of the specimens is evaluated. The results show that fibres eliminated brittle collapse and spalling of concrete at failure. Samples with fibres tend to have reduced maximum force and stiffness but increased ductility. The specimens with fibre content of 60 kg/m3 showed more ductile behaviour than the ones with minimum amount of conventional stirrups. The study suggests that combination of steel fibres and conventional re-bars can lead to less qualitative compactness of the self-compacting concrete, which in turn may reduce load bearing capacity and stiffness of the structure.

1 December 2025
Verified
Conference Paper
Closed access
SŠSolvita Šņore
Solvita Šņore
Ulvis SkadiņšUlvis Skadiņš
Ulvis Skadiņš
The paper examines the methods used to determine the mechanical properties of steel fibre-reinforced concrete (SFRC) slabs. The proper design of SFRC properties is fundamental to ensuring safe and sustainable building structures. Along with compressive strength, tensile strength and residual tensile strength of SFRC are essential in structural analysis. In this study, the mechanical properties of two full-scale cast-in-situ SFRC and two steel fibre-reinforced self-stressing concrete (SFRSSC) slabs are investigated. To assess the compressive strength of the concrete, both cubes and cylinders were cast and tested. Modified conversion factors for non-standard specimens were proposed to adjust the strength of standard specimen's size and shape. The moulded specimens were compared with the results of the specimens extracted from the slabs. To determine concrete tensile strength, prism specimens were cast and tested according to the three-point bending test method described in EN 14651. The tensile strength of notched prism specimens derived from three-point bending tests shows results similar to those of four-point bending tests; therefore, it can be used to evaluate the uniaxial tensile strength of steel fibre reinforced concrete. The findings of this research offer a better understanding of how to evaluate concrete mechanical properties for safe fibre concrete structural design.

1 December 2025
Verified
Conference Paper
Closed access
VAVenkata Siva Kumar Anumolu
Venkata Siva Kumar Anumolu
Ulvis SkadiņšUlvis Skadiņš
Ulvis Skadiņš
Fibre-reinforced concrete, if properly designed, can be a very efficient construction material. However, there are challenges to using them in load-bearing structures due to the high dispersion of strength properties. Therefore, structural design methods need to be calibrated with experimental data. This research aims to investigate factors that influence the shear capacity of steel fibre-reinforced concrete (SFRC) beams with conventional longitudinal reinforcement (Hybrid reinforcement). An experimental test program of 30 large beam specimens, 96 prism specimens, 45 cores, and 15 cubes was conducted. Beams were tested in a three-point bending configuration resulting in a shear failure. Additionally, the crack propagation and crack width were examined. Two types of fibres were used with diameter of 0.5 mm and length of 50 mm and 35 mm. The fibres at volume fractions of 40 kg m-³ and 80 kg m-³ were tested and compared with the specimens that were without steel fibres. Tools like a digital image correlation (DIC) were employed to monitor the crack propagation, and a web plot designer was utilized to analyse the fibre count. The results demonstrate that the fibres contributed up to 120% for the increase of shear capacity with fibre dosage of 40 kg/m³, and up to 220% when the dosage was 80 kg m-³. Beams with long fibres (50 mm) showed more abrupt failure caused by rupture of fibres. The results of the current study reveal that there are phenomena that cannot be captured based on the standard prism tests. These results are going to be used to calibrate numerical models in nonlinear models in non-linear finite element analysis software in future studies.