Atypical Hemolytic Uremic Syndrome (aHUS) is a severe, systemic, rare disease (RD) that can occur in people of all ages, and is associated with high rates of morbidity and mortality. Because the management of patients with aHUS can be difficult, more effective strategies should be implemented. Faculty members from several Italian Scientific Societies, Patient Associations and Regional Institutional Experts on RDs met to discuss aHUS management within a multidisciplinary team (MDT), using a Delphi process to develop consensus recommendations. Consensus (≥70 % agreement by faculty members) was reached on 51 statements with the aim of improving patient management and outcomes. These statements provide a unified framework for the differential diagnosis of aHUS, prompt recognition of the pathology, referral to RD reference centers, selecting between treatment relapse prevention measures options, patient management by a MDT and improving the overall awareness of aHUS. Despite the broad scope of the consensus statements, several unmet needs in the management of patients with aHUS were identified, including diagnostic suspicion, rapid genetic investigations, regular review of the centers of expertise (considering the number of treated patients), permanent clinical referral in treatment centers and widespread expertise among adult and pediatric specialists. We hope that this standardized framework will form the basis of the "digital ecosystem" concept and development of possible information technology solutions to assist the MDT involved in the management of patients with aHUS.
1 August 2021 in Transfusion and Apheresis Science
Background: Extracorporeal removal of bilirubin in patients with severe liver dysfunction is a key blood purification strategy. We conducted an ex vivo study to assess the quantitative capacity to remove bilirubin from plasma of a novel adsorptive cartridge. Methods: We studied a downscaled module of the BS330 Plasma Bilirubin Adsorption Column Cartridge (Jafron Biomedical, Zhuhai City, China) to minimize the plasma requirement in an ex vivo circulation using a solution of hyperbilirubinemic plasma. We measured the bilirubin concentration gap (ΔC) between inlet (Cpin) and outlet (Cpout) of the unit and we calculated the removal ratio (RR) as mass adsorbed at different time points. Moreover, we compared the ex vivo model with the bilirubin adsorption kinetics in a patient with acute on chronic liver failure treated with the BS330 cartridge. Results: Bilirubin concentration change across the cartridge at 30 min was 16.5%, and cartridge saturation was reached at 750 min. We used a minimodule downscaled to 1:3 and containing approximately 131 g of BS330 sorbent beads: the device retained 759 mg of bilirubin with a RR of 78.1% and a RR of 42.6% at 120 min. Thus, the adsorption capacity was 5.76 mg of bilirubin per gram of sorbent. Bilirubin adsorption kinetics in our clinical case with a full-scale unit shows a coherent trend with a total bilirubin mass adsorbed after 180 min of 470 mg. Discussion: Our findings provide the first assessment of bilirubin adsorption in an ex vivo model of plasma perfusion and can be used to design interventional studies in humans, providing guidance for an adequate prescription of treatment frequency and duration.