Bryan Richard Bzdek

Bryan Richard Bzdek

Auto-generated profile, based on publicly available information

Bryan Richard Bzdek

School of Chemistry, University of Bristol, Bristol, BS8 1TS, United Kingdom

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2020 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Open access
PDF file
BBBryan R. Bzdek
Bryan R. Bzdek
JRJonathan Reid
Jonathan Reid
JMJussi Malila
Jussi Malila
NPNønne L. Prisle
Nønne L. Prisle
Surface tension influences the fraction of atmospheric particles that become cloud droplets. Although surfactants are an important component of aerosol mass, the surface tension of activating aerosol particles is still unresolved, with most climate models assuming activating particles have a surface tension equal to that of water. By studying picoliter droplet coalescence, we demonstrate that surfactants can significantly reduce the surface tension of finite-sized droplets below the value for water, consistent with recent field measurements. Significantly, this surface tension reduction is droplet size-dependent and does not correspond exactly to the macroscopic solution value. A fully independent monolayer partitioning model confirms the observed finite-size-dependent surface tension arises from the high surface-to-volume ratio in finite-sized droplets and enables predictions of aerosol hygroscopic growth. This model, constrained by the laboratory measurements, is consistent with a reduction in critical supersaturation for activation, potentially substantially increasing cloud droplet number concentration and modifying radiative cooling relative to current estimates assuming a water surface tension. The results highlight the need for improved constraints on the identities, properties, and concentrations of atmospheric aerosol surfactants in multiple environments and are broadly applicable to any discipline where finite volume effects are operative, such as studies of the competition between reaction rates within the bulk and at the surface of confined volumes and explorations of the influence of surfactants on dried particle morphology from spray driers.

6 October 2020 in Anaesthesia
Verified
Journal Article
Open access
PDF file
JBJ. Brown
J. Brown
FGF. K. A. Gregson
F. K. A. Gregson
ASA. Shrimpton
A. Shrimpton
TCT. M. Cook
T. M. Cook
BBB. R. Bzdek
B. R. Bzdek
APA. E. Pickering
A. E. Pickering
Summary: The potential aerosolised transmission of severe acute respiratory syndrome coronavirus‐2 is of global concern. Airborne precaution personal protective equipment and preventative measures are universally mandated for medical procedures deemed to be aerosol generating. The implementation of these measures is having a huge impact on healthcare provision. There is currently a lack of quantitative evidence on the number and size of airborne particles produced during aerosol‐generating procedures to inform risk assessments. To address this evidence gap, we conducted real‐time, high‐resolution environmental monitoring in ultraclean ventilation operating theatres during tracheal intubation and extubation sequences. Continuous sampling with an optical particle sizer allowed characterisation of aerosol generation within the zone between the patient and anaesthetist. Aerosol monitoring showed a very low background particle count (0.4 particles.l −1 ) allowing resolution of transient increases in airborne particles associated with airway management. As a positive reference control, we quantitated the aerosol produced in the same setting by a volitional cough (average concentration, 732 (418) particles.l −1 , n = 38). Tracheal intubation including facemask ventilation produced very low quantities of aerosolised particles (average concentration, 1.4 (1.4) particles.l −1 , n = 14, p < 0.0001 vs. cough). Tracheal extubation, particularly when the patient coughed, produced a detectable aerosol (21 (18) l −1 , n = 10) which was 15‐fold greater than intubation (p = 0.0004) but 35‐fold less than a volitional cough (p < 0.0001). The study does not support the designation of elective tracheal intubation as an aerosol‐generating procedure. Extubation generates more detectable aerosol than intubation but falls below the current criterion for designation as a high‐risk aerosol‐generating procedure. These novel findings from real‐time aerosol detection in a routine healthcare setting provide a quantitative methodology for risk assessment that can be extended to other airway management techniques and clinical settings. They also indicate the need for reappraisal of what constitutes an aerosol‐generating procedure and the associated precautions for routine anaesthetic airway management.

5 October 2015 in Chemical Science
Verified
Journal Article
Open access
PDF file
BBBryan R. Bzdek
Bryan R. Bzdek
RPRory M. Power
Rory M. Power
SSStephen H. Simpson
Stephen H. Simpson
JRJonathan Reid
Jonathan Reid
CRC. Patrick Royall
C. Patrick Royall
Precise measurements of the surface tension and viscosity of airborne picolitre droplets can be accomplished using holographic optical tweezers.

16 April 2010 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
BBB. R. Bzdek
B. R. Bzdek
DRD. P. Ridge
D. P. Ridge
MJM. V. Johnston
M. V. Johnston
The exchange kinetics and thermodynamics of amines for ammonia in small (1–2 nm diameter) ammonium bisulfate and ammonium nitrate clusters were investigated using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS). Ammonium salt clusters were reacted with amine gas at constant pressure to determine the kinetics of exchange. The reverse reactions, where aminium salt clusters reacted with ammonia gas, were also studied, and no substitution of ammonia for amine was observed. Gibbs free energy changes for these substitutions were determined to be highly exothermic, −7 kJ/mol or more negative in all cases. Uptake coefficients (reaction probabilities) were found to be near unity, implying that complete exchange of ammonia in small clusters by amine would be expected to occur within several seconds to minutes in the ambient atmosphere. These results suggest that if salt clusters are a component of the sub-3 nm cluster pool, they are likely to be aminium salts rather than ammonium salts, even if they were initially formed as ammonium salts.

7 October 2016 in The Journal of Physical Chemistry A
Verified
Journal Article
Open access
YSYoung Chul Song
Young Chul Song
AHAllen E. Haddrell
Allen E. Haddrell
BBBryan R. Bzdek
Bryan R. Bzdek
JRJonathan Reid
Jonathan Reid
TBThomas Bannan
Thomas Bannan
CCChen Cai
Chen Cai
Organic aerosol particles are known to often absorb/desorb water continuously with change in gas phase relative humidity (RH) without crystallization. Indeed, the prevalence of metastable ultraviscous liquid or amorphous phases in aerosol is well-established with solutes often far exceeding bulk phase solubility limits. Particles are expected to become increasingly viscous with drying, a consequence of the plasticizing effect of water. We report here measurements of the variation in aerosol particle viscosity with RH (equal to condensed phase water activity) for a range of organic solutes including alcohols (diols to hexols), saccharides (mono-, di-, and tri-), and carboxylic acids (di-, tri-, and mixtures). Particle viscosities are measured over a wide range (10–3 to 1010 Pa s) using aerosol optical tweezers, inferring the viscosity from the time scale for a composite particle to relax to a perfect sphere following the coalescence of two particles. Aerosol measurements compare well with bulk phase studies (well-within an order of magnitude deviation at worst) over ranges of water activity accessible to both. Predictions of pure component viscosity from group contribution approaches combined with either nonideal or ideal mixing reproduce the RH-dependent trends particularly well for the alcohol, di-, and tricarboxylic acid systems extending up to viscosities of 104 Pa s. By contrast, predictions overestimate the viscosity by many orders of magnitude for the mono-, di-, and trisaccharide systems, components for which the pure component subcooled melt viscosities are ≫1012 Pa s. When combined with a typical scheme for simulating the oxidation of α-pinene, a typical atmospheric pathway to secondary organic aerosol (SOA), these predictive tools suggest that the pure component viscosities are less than 106 Pa s for ∼97% of the 50,000 chemical products included in the scheme. These component viscosities are consistent with the conclusion that the viscosity of α-pinene SOA is most likely in the range 105 to 108 Pa s. Potential improvements to the group contribution predictive tools for pure component viscosities are considered.

5 January 2021 in ACS Central Science
Verified
Journal Article
Closed access
JWJim S. Walker
Jim S. Walker
JAJustice Archer
Justice Archer
FGFlorence K. A. Gregson
Florence K. A. Gregson
SMSarah E. S. Michel
Sarah E. S. Michel
BBBryan R. Bzdek
Bryan R. Bzdek
JRJonathan Reid
Jonathan Reid