14 April 2020 in Proceedings of the National Academy of Sciences
Surface tension influences the fraction of atmospheric particles that become cloud droplets. Although surfactants are an important component of aerosol mass, the surface tension of activating aerosol particles is still unresolved, with most climate models assuming activating particles have a surface tension equal to that of water. By studying picoliter droplet coalescence, we demonstrate that surfactants can significantly reduce the surface tension of finite-sized droplets below the value for water, consistent with recent field measurements. Significantly, this surface tension reduction is droplet size-dependent and does not correspond exactly to the macroscopic solution value. A fully independent monolayer partitioning model confirms the observed finite-size-dependent surface tension arises from the high surface-to-volume ratio in finite-sized droplets and enables predictions of aerosol hygroscopic growth. This model, constrained by the laboratory measurements, is consistent with a reduction in critical supersaturation for activation, potentially substantially increasing cloud droplet number concentration and modifying radiative cooling relative to current estimates assuming a water surface tension. The results highlight the need for improved constraints on the identities, properties, and concentrations of atmospheric aerosol surfactants in multiple environments and are broadly applicable to any discipline where finite volume effects are operative, such as studies of the competition between reaction rates within the bulk and at the surface of confined volumes and explorations of the influence of surfactants on dried particle morphology from spray driers.
6 October 2020 in Anaesthesia
Summary: The potential aerosolised transmission of severe acute respiratory syndrome coronavirus‐2 is of global concern. Airborne precaution personal protective equipment and preventative measures are universally mandated for medical procedures deemed to be aerosol generating. The implementation of these measures is having a huge impact on healthcare provision. There is currently a lack of quantitative evidence on the number and size of airborne particles produced during aerosol‐generating procedures to inform risk assessments. To address this evidence gap, we conducted real‐time, high‐resolution environmental monitoring in ultraclean ventilation operating theatres during tracheal intubation and extubation sequences. Continuous sampling with an optical particle sizer allowed characterisation of aerosol generation within the zone between the patient and anaesthetist. Aerosol monitoring showed a very low background particle count (0.4 particles.l −1 ) allowing resolution of transient increases in airborne particles associated with airway management. As a positive reference control, we quantitated the aerosol produced in the same setting by a volitional cough (average concentration, 732 (418) particles.l −1 , n = 38). Tracheal intubation including facemask ventilation produced very low quantities of aerosolised particles (average concentration, 1.4 (1.4) particles.l −1 , n = 14, p < 0.0001 vs. cough). Tracheal extubation, particularly when the patient coughed, produced a detectable aerosol (21 (18) l −1 , n = 10) which was 15‐fold greater than intubation (p = 0.0004) but 35‐fold less than a volitional cough (p < 0.0001). The study does not support the designation of elective tracheal intubation as an aerosol‐generating procedure. Extubation generates more detectable aerosol than intubation but falls below the current criterion for designation as a high‐risk aerosol‐generating procedure. These novel findings from real‐time aerosol detection in a routine healthcare setting provide a quantitative methodology for risk assessment that can be extended to other airway management techniques and clinical settings. They also indicate the need for reappraisal of what constitutes an aerosol‐generating procedure and the associated precautions for routine anaesthetic airway management.
5 October 2015 in Chemical Science
Precise measurements of the surface tension and viscosity of airborne picolitre droplets can be accomplished using holographic optical tweezers.
16 April 2010 in Atmospheric Chemistry and Physics
The exchange kinetics and thermodynamics of amines for ammonia in small (1–2 nm diameter) ammonium bisulfate and ammonium nitrate clusters were investigated using electrospray ionization Fourier transform ion cyclotron resonance mass spectrometry (FT-ICR-MS). Ammonium salt clusters were reacted with amine gas at constant pressure to determine the kinetics of exchange. The reverse reactions, where aminium salt clusters reacted with ammonia gas, were also studied, and no substitution of ammonia for amine was observed. Gibbs free energy changes for these substitutions were determined to be highly exothermic, −7 kJ/mol or more negative in all cases. Uptake coefficients (reaction probabilities) were found to be near unity, implying that complete exchange of ammonia in small clusters by amine would be expected to occur within several seconds to minutes in the ambient atmosphere. These results suggest that if salt clusters are a component of the sub-3 nm cluster pool, they are likely to be aminium salts rather than ammonium salts, even if they were initially formed as ammonium salts.
7 October 2016 in The Journal of Physical Chemistry A
Organic aerosol particles are known to often absorb/desorb water continuously with change in gas phase relative humidity (RH) without crystallization. Indeed, the prevalence of metastable ultraviscous liquid or amorphous phases in aerosol is well-established with solutes often far exceeding bulk phase solubility limits. Particles are expected to become increasingly viscous with drying, a consequence of the plasticizing effect of water. We report here measurements of the variation in aerosol particle viscosity with RH (equal to condensed phase water activity) for a range of organic solutes including alcohols (diols to hexols), saccharides (mono-, di-, and tri-), and carboxylic acids (di-, tri-, and mixtures). Particle viscosities are measured over a wide range (10–3 to 1010 Pa s) using aerosol optical tweezers, inferring the viscosity from the time scale for a composite particle to relax to a perfect sphere following the coalescence of two particles. Aerosol measurements compare well with bulk phase studies (well-within an order of magnitude deviation at worst) over ranges of water activity accessible to both. Predictions of pure component viscosity from group contribution approaches combined with either nonideal or ideal mixing reproduce the RH-dependent trends particularly well for the alcohol, di-, and tricarboxylic acid systems extending up to viscosities of 104 Pa s. By contrast, predictions overestimate the viscosity by many orders of magnitude for the mono-, di-, and trisaccharide systems, components for which the pure component subcooled melt viscosities are ≫1012 Pa s. When combined with a typical scheme for simulating the oxidation of α-pinene, a typical atmospheric pathway to secondary organic aerosol (SOA), these predictive tools suggest that the pure component viscosities are less than 106 Pa s for ∼97% of the 50,000 chemical products included in the scheme. These component viscosities are consistent with the conclusion that the viscosity of α-pinene SOA is most likely in the range 105 to 108 Pa s. Potential improvements to the group contribution predictive tools for pure component viscosities are considered.
5 January 2021 in ACS Central Science