Zhangning Xie

Zhangning Xie

Auto-generated profile, based on publicly available information

Zhangning Xie

Shanghai Institute of Measurement and testing Technology Co. Ltd

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 December 2023 in Measurement Science and Technology
Verified
Journal Article
Open access
PDF file
ZXZhangning Xie
Zhangning Xie
TJTao Jin
Tao Jin
LLLihua Lei
Lihua Lei
ZLZichao Lin
Zichao Lin
YYYulin Yao
Yulin Yao
Xinbin ChengXinbin Cheng
Xinbin Cheng
The measurement of critical dimensions in the field of integrated circuits has moved from 7 nm to 5 nm. The existing chromium atomic lithography grating has a pitch period of 4700 l mm−1 and uniformity of picometer, and the interferometric signal period based on the above grating is as small as 106.4 nm, which brings new problems and challenges to the accurate processing of the signal. This paper investigates the error characteristics of ultra-high precision grating interferometric signals, establishes a Heydemann correction mathematical model for high inscribed line density grating interferometric signals, corrects the grating interferometer signals based on the random sample consensus (RANSAC), and verifies the effectiveness of the algorithm through simulation. By comparing the repeatability and linearity of the original algorithm and the self-traceable grating interferometric displacement measurement data processed by RANSAC, the conclusion that the standard deviation of the self-traceable grating interferometer repeat measurement after RANSAC is 1.60 nm in a 10 000 nm travel is obtained, and the purpose of improving the stability and uniformity of the signal solution with the algorithm of this paper is achieved, which is important for the study of laser interferometer and grating interferometer The results show that the stability and uniformity of the signal solution can be improved by the algorithm of this paper, which is of great significance for the study of the displacement solution of laser and grating interferometers.

26 May 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZXZhangning Xie
Zhangning Xie
LLLiqin Liu
Liqin Liu
LLLihua Lei
Lihua Lei
The atomic force microscope (AFM) is a cornerstone of nanoscale measurement technology. Its measurement accuracy directly affects the quality of nanofabrication and characterization. This study presents a method for correcting angular errors in planar scanners. The correction method uses a high line-density angular calibrator. It addresses the common problem of angular coupling errors in AFM systems. The sources of angular inaccuracies—mechanical structural deviations, sensor crosstalk, and environmental interference—are systematically analyzed. An angular error propagation model is established to quantify each source’s contribution to measurement uncertainty. Furthermore, a directly traceable angular calibration approach is proposed. This approach uses a two-dimensional chromium grating reference material with a periodic structure nominal defined value of 212.8 nm and precisely orthogonal angles. As a result, it enables accurate nanoscale angular measurements. Experimental results show that the correction method greatly reduces angular coupling errors. In the open-loop configuration, the coupling angle drops from 0.305° to a negligible level. In closed-loop mode, it drops from 3.322° to 0.007°. This fulfills the precision requirements of nanometrology. These findings provide a new technical pathway for angular calibration in metrological-grade AFMs. The work has significant implications for enhancing both measurement accuracy and metrological traceability at the nanoscale.

12 June 2026 in Measurement Science and Technology
Verified
Journal Article
Closed access
DXDongbai Xue
Dongbai Xue
ZXZhangning Xie
Zhangning Xie
ZCZhecheng Chen
Zhecheng Chen
YXYuying Xie
Yuying Xie
YYYaao Yang
Yaao Yang
Xinbin ChengXinbin Cheng
Xinbin Cheng
Nanoscale dimensional metrology is one of the most important tasks in nanotechnology, as the dimensions of nanostructures provide the fundamental information on which many properties depend. High-end atomic force microscopes (AFMs) are essential instruments for traceable calibration of nanostructures, providing unprecedented resolution and accuracy with traceability to the International System of Units ensured by laser interferometers. However, accurate displacement measurement using laser interferometers requires strict environmental control and compensation, making them highly demanding. In this paper, we propose a novel design of a stability-enhanced AFM (S-AFM) that employs a self-validating grating interferometer (SGI) as the metrological system. The SGI is directly traceable to the chromium atomic transition frequency and exhibits superior stability, with a displacement drift of less than 10 nm over 12 h. By integrating the SGI into the S-AFM, a relative deviation of repeated measurements better than 10 −4 was achieved. Long-term stability tests, performed by repeatedly measuring the same position on a periodic calibration grating over 12 h, demonstrated a measurement deviation within ±0.1 nm. And a grating pitch measurement uncertainty better than 1 nm was achieved. The accuracy and stability of the developed S-AFM were verified, indicating its potential for implementation in measurement and calibration tasks within a workshop.