Lihua Lei

Lihua Lei

Auto-generated profile, based on publicly available information

Lihua Lei

Shanghai Institute of Measurement and Testing Technology, Shanghai, China

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 December 2020 in IEEE Access
Verified
Journal Article
Open access
LLLihua Lei
Lihua Lei
ZXZhangning Xie
Zhangning Xie
HZHuichen Zhu
Huichen Zhu
YGYuqing Guan
Yuqing Guan
MKMing Kong
Ming Kong
YFYunxia Fu
Yunxia Fu
To meet the needs of three-dimensional (3D) measurement and to achieve the high-precision fitting of the central axis of a screw thread, this study performed complex processing of the 3D structures on the surface of the thread central axis. Moreover, this study examined the problems of long processing time and low accuracy caused by the use of a point cloud with a large data volume. An improved particle swarm optimization algorithm was used to develop a fitting method for the central axis of the three-dimensional (3D) thread of a 3D convex hull. SolidWorks was used to simulate the 3D parts of a standard thread, and the Point Cloud Library was used to generate a 3D simulated point cloud for the thread surface. The maximum deviation between the fitted line and the line obtained in the two-dimensional (2D) projection method was $0.12~\mu \text{m}$ . An experiment was conducted using data regarding the tip of the plug gauge surface. The variation in the distance between the obtained straight line and the 3D point cloud was smaller than that between the obtained straight line and the 2D point cloud. Moreover, the calculation speed was higher when using the 3D method than when using the 2D method.

1 October 2015 in Precision Engineering
Verified
Journal Article
Closed access
YCYu xiao Cai
Yu xiao Cai
YLYuan Li
Yuan Li
LLLihua Lei
Lihua Lei
GFGuofang Fan
Guofang Fan
LJLi Jian
Li Jian
SZSonglin Zhuang
Songlin Zhuang

18 June 2021 in IEEE Access
Verified
Journal Article
Open access
LLLihua Lei
Lihua Lei
YGYuqing Guan
Yuqing Guan
YZYanhua Zeng
Yanhua Zeng
LZLin Zhao
Lin Zhao
ZXZhangning Xie
Zhangning Xie
YFYunxia Fu
Yunxia Fu
According to the transmission mode of polarized light in Mueller ellipsometry, a characterization method for the thickness and optical constants of isotropic nano films based on Self-Adaptive Differential Evolution algorithm (SADE) is proposed. By establishing the least square model of the output light intensity with respect to the Mueller matrix of the standard sample to be measured, the elements of the Mueller matrix are solved by using the Sade algorithm, and the Mueller spectral curve obtained by fitting is compared with that measured by DRC-MME, and the film thickness is calculated by using the transfer matrix. The SiO 2 / Si standard samples with calibration values of 100.4 nm and 121.56 nm are simulated and calculated. The experiment shows that: when numbers of iterations accumulated to 65 and 80 respectively, the residual square sum of the light intensity of the objective function converges to the minimum values of 1.24 and 1.02. The calculated film thickness values are 101.25nm and 120.53nm respectively, and the relative errors are both less than 1%. It proves the characteristics of simple calculation, fast convergence and accurate global optimal solution.

26 May 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
ZXZhangning Xie
Zhangning Xie
LLLiqin Liu
Liqin Liu
LLLihua Lei
Lihua Lei
The atomic force microscope (AFM) is a cornerstone of nanoscale measurement technology. Its measurement accuracy directly affects the quality of nanofabrication and characterization. This study presents a method for correcting angular errors in planar scanners. The correction method uses a high line-density angular calibrator. It addresses the common problem of angular coupling errors in AFM systems. The sources of angular inaccuracies—mechanical structural deviations, sensor crosstalk, and environmental interference—are systematically analyzed. An angular error propagation model is established to quantify each source’s contribution to measurement uncertainty. Furthermore, a directly traceable angular calibration approach is proposed. This approach uses a two-dimensional chromium grating reference material with a periodic structure nominal defined value of 212.8 nm and precisely orthogonal angles. As a result, it enables accurate nanoscale angular measurements. Experimental results show that the correction method greatly reduces angular coupling errors. In the open-loop configuration, the coupling angle drops from 0.305° to a negligible level. In closed-loop mode, it drops from 3.322° to 0.007°. This fulfills the precision requirements of nanometrology. These findings provide a new technical pathway for angular calibration in metrological-grade AFMs. The work has significant implications for enhancing both measurement accuracy and metrological traceability at the nanoscale.