Debin Zhang

Debin Zhang

Auto-generated profile, based on publicly available information

Debin Zhang

Advanced Power Conversion Center, School of Automation, Beijing Institute of Technology, Beijing, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 January 2022 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DSDeshang Sha
Deshang Sha
YZYuting Zhao
Yuting Zhao
DZDebin Zhang
Debin Zhang
This article proposes a fully digital variable switching frequency and deadtime control method for a synchronous rectifier buck dc–dc converter with an inverse coupled inductor. It does not need auxiliary circuits, zero-crossing detection (ZCD), or high-bandwidth sensors. Even in facing the polyline shape of the current in inductors due to the coupling effect, zero-voltage switching (ZVS) can be achieved with the proposed varying switching frequency control to make the turn off current be constant. Based on ZVS achievement of the power switches, the deadtime is variable to reduce the conduction loss over body diodes further. The modes and resonant process are analyzed in detail. A 1-kW experimental prototype was built to verify the effectiveness of the proposed control method. The peak efficiency is over 99% in the experimental test.

21 February 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
PMPeisong Ma
Peisong Ma
DSDeshang Sha
Deshang Sha
DZDebin Zhang
Debin Zhang
In this article, an improved modulation and variable frequency control strategy for a single-stage high-frequency isolated semi-dual-active-bridge-based ac–dc converter is proposed, which can achieve full operating range (the entire ac line cycle and full-load range) zero-voltage switching (ZVS) and high efficiency. Compared with the basic variable frequency control, an improved variable frequency strategy can reduce the envelope of leakage inductor peak current and reduce the dependence and sensitivity to the load power. More accurate ZVS criteria in view of the magnetizing inductor Lm are proposed. Seven operating modes are adopted and the transition among them is seamless. Three control variables are used in every mode. Wide voltage conversion gain and high-quality grid-side ac current can be obtained without mandatory current-tracking loops. In addition, detailed comparisons among different control strategies and different mode operating regions are analyzed. The design of the transformer and inductor is not affected at all despite the switching frequency varies. A 250-W experimental prototype was built to verify the effectiveness of the proposed improved variable frequency control strategy.

8 August 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DZDebin Zhang
Debin Zhang
DSDeshang Sha
Deshang Sha
CGCongzhe Gao
Congzhe Gao
XLXiao Liu
Xiao Liu
HLHanwen Long
Hanwen Long
YGYang Gao
Yang Gao
Aim to charge all submodule (SM) capacitors of the full-bridge modular multilevel converter (FB-MMC) to their nominal voltage values smoothly and effectively, this article proposes a closed-loop soft startup strategy by utilizing the negative output voltage of FB-SM, which completely suppresses the potential inrush currents at the startup process. Based on the analysis of the precharging process of FB-MMC with load, when bypassing the current limiting resistors, the inrush currents are induced owing to the presence of load. To solve this issue, an improved startup strategy is further proposed by intentionally controlling the dc voltage to zero. With this strategy, the main ac contactor is closed with zero current, which is beneficial for extending the service life of mechanical switches. Besides, the overall control system is integrated and optimized because separately designed startup control is not required, thereby reducing the computational burden of digital controllers. Moreover, the SM capacitors can be charged rapidly by a ramp shaped charging current, and equal charging of all SMs during startup process can be guaranteed with the voltage balancing control algorithm. Simulation and experimental results of three-phase FB-MMC rectifier interfaced with grid and 5 kV dc are provided to validate the feasibility and effectiveness of the proposed startup strategy.

24 March 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DZDebin Zhang
Debin Zhang
DSDeshang Sha
Deshang Sha
YZYining Zhao
Yining Zhao
CGCongzhe Gao
Congzhe Gao
XLXiao Liu
Xiao Liu
To further improve the power supply sustainability of the ac/dc hybrid distribution networks, this article proposes a control strategy for the modular multilevel converter (MMC) under grid-side open-circuit fault, which is based on independent arm current control. Firstly, the behaviors of the MMC after the faults are analyzed, including single-phase and two-phase open-circuit faults. For single-phase open-circuit fault, the proposed strategy can be achieved by reconfiguring the amplitude and phase of the arm currents, thereby eliminating the zero-sequence current. For two-phase open-circuit fault, both the arm currents and voltages need to be reconfigured. After that, a method for detecting and locating specific faults is provided, which can be implemented by detecting the amplitude of the zero-sequence current. Besides, the postfault characteristics of the MMC under single-phase open-circuit condition are given, including submodule (SM) capacitor voltage ripple, circulating current, arm rms current and arm peak current. According to it, long-term postfault operation of the MMC can be guaranteed with 50% of the rated power. Additionally, stable dc-bus voltage and balanced SM capacitor voltage are satisfied even though one phase is disconnected. Moreover, with the proposed control strategy, although the MMC is able to operate for a short period of time in emergency situations when two phases are disconnected, it is not supposed to transmit power due to the inevitable large current on neutral conductors. Finally, the feasibility and effectiveness of the proposed control strategy is validated by simulation and experimental results.

28 July 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DZDebin Zhang
Debin Zhang
DSDeshang Sha
Deshang Sha
YNYongliang Ni
Yongliang Ni
This letter proposes a current and magnetic flux dc bias suppression strategy for the modular multilevel converter (MMC)-based dc transformers. With this strategy, dc bias can be suppressed within half a switching cycle under different transient conditions, including ac-link voltage amplitude, switching frequency, and phase-shift angle variation. By rearranging the moment and quantity of SMs insertion or bypass, the volt–seconds balance of each arm voltage can be realized, thereby eliminating dc bias caused by amplitude step changes. Besides, dc bias caused by switching frequency and phase-shift angle step changes can be eliminated by adjusting phase-shift angle in the transient period. Experimental results are provided to validate the feasibility and effectiveness of the proposed dynamic control.

10 November 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DZDebin Zhang
Debin Zhang
DSDeshang Sha
Deshang Sha
YZYining Zhao
Yining Zhao
The modular multilevel converter-based dc transformers (MMC-DCT) are becoming essential parts of medium voltage dc applications. The implementation of zero-voltage switching (ZVS) is necessary for MMC-DCT to achieve higher switching frequencies, thereby improving power density and realizing lightweight. However, with conventional phase shift control, the ZVS range is very narrow. To solve this issue, a variable ac-link voltages and frequency control strategy is proposed, which is achieved by adjusting the number of constantly inserted or bypassed submodules (SMs) within a switching cycle. Meanwhile, the capacitor voltage-balancing algorithm is introduced. With this strategy, the ZVS range is extended over a wide power range. Moreover, since the switching loss of SMs and core loss of transformer are reduced, the efficiency of MMC-DCT is significantly improved at light power. Finally, the feasibility and effectiveness of the proposed control strategy is validated by experimental results.