Ashish Ranjan Dash

Ashish Ranjan Dash

Auto-generated profile, based on publicly available information

Ashish Ranjan Dash

Centurion University of Technology and Management, Odisha, India

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
19 December 2019 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
MMMrutyunjaya Mangaraj
Mrutyunjaya Mangaraj
APAnup Kumar Panda
Anup Kumar Panda
TPTrilochan Penthia
Trilochan Penthia
ADAsish Ranjan Dash
Asish Ranjan Dash
In this study, the design and implementation of a new hybrid soft computing control technique called Levenberg–Marquardt backpropagation (LMBP)‐based icosϕ is proposed. Two different compensation techniques are evaluated for the performance analysis of three‐phase three‐wire (3P3W) voltage source converter (VSC)‐based DSTATCOM. The first one is the conventional icosϕ control technique whereas the other one is called the LMBP‐based icosϕ control technique. The better power quality of the system is obtained using the proposed control algorithm by maintaining a less voltage across the capacitor as compared to the conventional one. So, the reduction in the size of the DSTATCOM is realised by the LMBP‐based control algorithm. Furthermore, the performance parameters such as load balancing, harmonics elimination, power factor improvement, and voltage regulation are evaluated under both balanced and unbalanced loading conditions as per the IEEE guidelines. The effectiveness of the proposed controller is studied in the MATLAB/Simulink environment and also validated with a low power rated prototype experimental results.

26 September 2018 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
ADAshish Ranjan Dash
Ashish Ranjan Dash
APAnup Kumar Panda
Anup Kumar Panda
RPRanjeeta Patel
Ranjeeta Patel
TPTrilochan Penthia
Trilochan Penthia

31 May 2019 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Closed access
PDF file
ADAshish Ranjan Dash
Ashish Ranjan Dash
APAnup Kumar Panda
Anup Kumar Panda
RLRajesh Kumar Lenka
Rajesh Kumar Lenka

2 September 2019 in IET Generation, Transmission & Distribution
Verified
Journal Article
Open access
PDF file
ADAshish Ranjan Dash
Ashish Ranjan Dash
APAnup Kumar Panda
Anup Kumar Panda
RLRajesh Kumar Lenka
Rajesh Kumar Lenka
RPRanjeeta Patel
Ranjeeta Patel
In this study, a real‐time empirical mode decomposition (RT‐EMD) based control technique is adopted for effective mitigation of system harmonics under ideal and non‐ideal supply voltage conditions. The proposed control algorithm takes the active component of load current samples and the positive sequence voltage component for generating the desired reference. The fundamental component of load current is found by employing RT‐EMD, which decomposes the distorted non‐linear sample into a finite number of fine‐scale signals termed as intrinsic mode function (IMF). Each IMF is extracted adopting continuous calculation of upper and lower envelopes using a series pipeline structure which decreases the computational complexity. The proposed control algorithm takes the positive sequence voltage component for generating the desired reference so that the system can operate in non‐sinusoidal grid voltage conditions. The proposed control algorithm adopts carrier‐based modulation scheme for switching of the inverter module. The effectiveness of the proposed control approach is investigated in MATLAB‐Simulink environment with balanced and unbalanced loading condition and its experimental validation is carried out by a hardware prototype model using a Spartan 6 FPGA controller.

28 March 2025 in Expert Systems with Applications
Verified
Journal Article
Closed access
RMRajesh Kumar Mishra
Rajesh Kumar Mishra
ADAshish Ranjan Dash
Ashish Ranjan Dash
APAnup Kumar Panda
Anup Kumar Panda

27 August 2021
Verified
Conference Paper
Closed access
RBRashmi Rekha Behera
Rashmi Rekha Behera
ADAshish Ranjan Dash
Ashish Ranjan Dash
APAnup Kumar Panda
Anup Kumar Panda
This paper presents a cascaded transformer coupled multilevel inverter which is able to generate higher voltage levels with reduced switches. The complete design aspect and modulation method of the proposed a cascaded transformer coupled multilevel inverter is explained along with its harmonic compensation ability when operated as a shunt active power filter. The proposed shunt active power filter is operating with single DC-link which minimizes the complexity for voltage balancing. Its topology is modular in structure and based on three phase voltage source bridge inverter. It minimizes the component count drastically with comparison to number of voltage levels. The proposed filter is examined under balanced grid voltage with highly nonlinear load and validated through MATLAB/SIMULINK software.