18 September 2023 in IEEE Transactions on Industry Applications
The growing demand for high-efficiency power con-verters with silicon carbide (SiC) devices at high switching frequencies has fueled an interest in non-auxiliary circuit-based soft switching techniques, particularly the variable switching frequency control for zero-voltage switching (VF-ZVS). Besides increasing the Total Harmonic Distortion (THD), applying the full ZVS range to three-phase SiC/Si Hybrid Active Neutral Point Clamped (HANPC) converters leads to a rise in conduction loss. This issue is exacerbated by the use of Si IGBT, as it generates significantly more conduction loss than SiC MOSFET in medium and small power HANPC. Consequently, a power loss optimized VF-ZVS (OVF-ZVS), based on a precise loss model, is proposed to enhance efficiency by considering the effect of the current ripple on device loss. This OVF-ZVS optimizes the switching frequency to minimize the total loss of three-phase switching devices across all load ranges. Meanwhile, the variable switching frequency range and LCL parameters are optimized to strike a balance between superior output current quality, power density, etc. Simulation and exper-imentation using a 10kW HANPC converter prototype illustrate the effectiveness of the proposed comprehensive optimization, further highlighting the reduction in THD and device loss.
7 June 2024 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The zero-voltage-switching variable frequency control (ZVS-VF) can achieve ZVS without auxiliary circuit. Nevertheless, it will increase switching losses under light load, and conduction losses under heavy load, thus affecting efficiency. This is particularly evident in scenarios with varying DC side voltage and load power (e.g. photovoltaic systems). To address this issue, our proposed continuous space vector modulation (CSVM)-Improved discontinuous space vector modulation (IDSVM) hybrid strategy can improve the efficiency at both light and heavy loads under various DC side voltages, when employing ZVS-VF to a 3L inverter. This is achieved by leveraging the losses performance of diverse modulations, CSVM is chosen to reduce switching losses under light load, while IDSVM is selected to limit conduction losses under heavy load. Additionally, with the proposed hybrid modulation, the full ZVS range can be realized in the 3L inverter. The modulation transition point is determined by the power losses analysis, ZVS range analysis and smooth transition constraint. It can be adaptively adjusted to achieve smooth transition of different modulation methods under varying operating conditions. The experimental results from a 10kW 3L Active Neutral-Point-Clamped (ANPC) inverter demonstrate that the proposed strategy improves efficiency by 3.7% for light load and 1.94% for full load compared to the conventional constant frequency control.