Yan Du

Yan Du

Auto-generated profile, based on publicly available information

Yan Du

School of Electrical Engineering and Automation, Hefei University of Technology, Hefei 230009, China

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 September 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
YSYong Shi
Yong Shi
WHWei He
Wei He
BXBao Xie
Bao Xie
YDYan Du
Yan Du
XYXiangzhen Yang
Xiangzhen Yang
JSJianhui Su
Jianhui Su
Most current proton exchange membrane fuel cell (PEMFC) fault diagnosis models are not updated after offline training is completed, so they cannot learn new data features. For this problem, a PEMFC fault diagnosis model based on an equivalent circuit and an online sequential extreme learning machine (OS-ELM) framework is proposed. Under different operating conditions, the range of equivalent circuit element values is different, which is conducive to fault diagnosis. Element values constitute a dataset, from which OS-ELM is used to learn data features, and PEMFC fault diagnosis and isolation can be accomplished. OS-ELM has online learning capability. During the operation of PEMFC, equivalent circuit fitting is performed on multiple sets of sample data obtained using electrical impedance spectroscopy (EIS). Optimized fuzzy C-means (FCM) is used to cluster and partition sample data for online updating of OS-ELM models. The experimental results show that the proposed PEMFC fault diagnosis model not only has the speed and accuracy of fault diagnosis but also has the ability to learn fault characteristics online.

11 July 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
XYXiangzhen Yang
Xiangzhen Yang
JWJinxiu Wang
Jinxiu Wang
YDYan Du
Yan Du
CLCan Liu
Can Liu
TZTao Zhang
Tao Zhang
JZJian Zhang
Jian Zhang
All-switches zero voltage switching (ZVS) and lower current stress are the most important challenges for improving the efficiency of dual-active-bridge (DAB) converters operating in the bidirectional full-load range and wide voltage range applications. Triple-phase-shift (TPS) has three control degrees of freedom and it is a more flexible way to extend the ZVS range in all kinds of operating conditions. In order to improve the efficiency of DAB converters, a new optimal current stress in TPS (OCS-TPS) control is proposed to minimize the current stress as well as achieve all-switches ZVS within the bidirectional full-load range and wide voltage range applications. Firstly, seven specific switching modes satisfying the ZVS conditions under step-up and step-down are selected from 12 TPS switching modes. Secondly, the issue of current stress minimization is turned into an extreme optimization problem with equality constraints of desired transmission power and inequality constraints of ZVS conditions in selected switching modes. The Karush-Kuhn-Tucker (KKT) algorithm is employed to solve this optimization issue. Then two switching modes are chosen to form the high-load range ZVS and low-load range partial-switches ZCS/ZVS in the case of step-down and step-up operations respectively. Therefore, the phase-shift ratios of selected switching modes in the low-load range are further optimized by adding an offset value to achieve all-switches ZVS. Finally, the effectiveness of the proposed strategy is verified by the experimental results.

18 September 2023 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
ZCZhicheng Cai
Zhicheng Cai
YDYan Du
Yan Du
JSJianhui Su
Jianhui Su
XYXiangzhen Yang
Xiangzhen Yang
YSYong Shi
Yong Shi
JZJian Zhang
Jian Zhang
The growing demand for high-efficiency power con-verters with silicon carbide (SiC) devices at high switching frequencies has fueled an interest in non-auxiliary circuit-based soft switching techniques, particularly the variable switching frequency control for zero-voltage switching (VF-ZVS). Besides increasing the Total Harmonic Distortion (THD), applying the full ZVS range to three-phase SiC/Si Hybrid Active Neutral Point Clamped (HANPC) converters leads to a rise in conduction loss. This issue is exacerbated by the use of Si IGBT, as it generates significantly more conduction loss than SiC MOSFET in medium and small power HANPC. Consequently, a power loss optimized VF-ZVS (OVF-ZVS), based on a precise loss model, is proposed to enhance efficiency by considering the effect of the current ripple on device loss. This OVF-ZVS optimizes the switching frequency to minimize the total loss of three-phase switching devices across all load ranges. Meanwhile, the variable switching frequency range and LCL parameters are optimized to strike a balance between superior output current quality, power density, etc. Simulation and exper-imentation using a 10kW HANPC converter prototype illustrate the effectiveness of the proposed comprehensive optimization, further highlighting the reduction in THD and device loss.

19 August 2021 in Journal of Electrical Engineering & Technology
Verified
Journal Article
Closed access
PDF file
XYXiangzhen Yang
Xiangzhen Yang
QYQiuQiang Yang
QiuQiang Yang
YDYan Du
Yan Du
LSLiLing Sun
LiLing Sun
WDWanwan Deng
Wanwan Deng

28 March 2026 in Processes
Verified
Journal Article
Open access
PDF file
JWJiaqing Wang
Jiaqing Wang
XHXudong Hu
Xudong Hu
JLJinzhong Li
Jinzhong Li
TCTao Cheng
Tao Cheng
LLLeixin Liang
Leixin Liang
YDYan Du
Yan Du
The hybrid parallel operation of the grid-following (GFL) converter and the grid-forming (GFM) converter has become a typical scenario in distribution networks. The vastly different control philosophies and dynamics between the two give rise to complex small-signal stability issues, especially under weak grids. Traditional methods primarily rely on equivalent models or impedance-based approaches at fixed operating points, which struggle to reveal the system instability mechanisms when the capacity ratio between the two types of converters changes. This paper establishes a three-port dynamic average model for a grid-connected system with heterogeneous GFL-GFM converters. Using the participation factor analysis method, the system’s dominant modes are identified, and the key parameters influencing oscillations at different frequencies, as well as their formation processes, are revealed. Furthermore, a stability analysis method for variable capacity ratios is proposed. This method re-performs modal analysis based on the varying capacities of the GFM and GFL converters, revealing the dominant factors and influencing mechanisms of system instability during capacity transitions. Finally, a simulation model is built in PSCAD/EMTDC to verify the correctness of the proposed three-port model and the theoretical analysis results.