Positron emission tomography (PET) is an important molecular image modality and its application on preclinical research has increased during last decades. Thus, in laboratory practice, it is important to implement a quality control of the equipment, since intrinsic factors influence the image quality. The objective of this work was to perform and implement spatial resolution tests for the small animal PET scanner of the Molecular Imaging Laboratory, LIM/CDTN. Empirically, spatial resolution of a PET scanner can be determined from the measurement of point or linear sources and FWHM (full width half maximum) analysis of the respective linear profiles. In this work, a point source of 22Na and a hot rod style phantom filled with 18F-FDG solution were used. Acquisition and reconstruction of images were performed with the LabPET 1.12.1 software, provided by the equipment manufacturer. Image reconstruction parameters followed the LIM standard protocol: MLEM-3D algorithm, 20 iterations, no high resolution mode, no attenuation or scatter corrections, no post-filtering. PeakFit® and Amide softwares were used to perform images post-processing. The results indicate that the scanner has an adequate spatial resolution and its value is compatible with values reported in international studies performed on similar equipments.
18 September 2022 in Brazilian Journal of Radiation Sciences
JSJuliana Batista da Silva
This study aimed to evaluate the general performance of the preclinical PET scanner (LabPET Solo 4, GE) at CDTN/CNEN using the NEMA NU 4-2008 protocol. The performance parameters include: (i) spatial resolution; (ii) scatter fraction and counts rate performance; (iii) sensitivity and (iv) image quality. For the evaluation specific simulators and a sealed radioactive source of Sodium-22 were used. The results revealed that the NEMA-based radial spatial resolution ranged from 1.79 mm at the center of the FOV to 2.49 mm at a radial offset of 25mm. Tangential resolution ranged from 1.95mm at the center of the FOV to 3.50mm at a radial offset of 25mm. Axial resolution ranged from 1.78mm at the center of the FOV to 5.42mm at a radial offset of 25mm. Iterative image reconstruction improved the radial spatial resolution to 0.93mm at the center of the FOV. For the mouse-sized phantom, the peak noise equivalent count rate (NECR) was 37.8kcps at 85MBq whereas the peak true count rate was 169.9kcps at 125MBq with a count loss of 7.8% for the maximum rate reached at 103.3MBq. The peak of sensitivity (S) and absolute sensitivity (SA) at the center of axial field-of-view (FOV) is 5.7cps.Bq-1 and 0.63%, respectively. The overall imaging capabilities of the scanner were assessed using the NEMA image-quality phantom. The image roughness was 9.5%. Spillover rates (SORs) in air and in water were 0.26 and 0.17 respectively. The recovery coefficients (RCs) were 0.12 for the 1-mm-diameter rod and 0.91 for the 5-mm-diameter rod. The results demonstrate that CDTN/CNENsmall animal PET scanner has adequate reliability and acquired images are compatible with international quality standards for the molecular imaging research.
3 April 2024 in Brazilian Journal of Radiation Sciences
Nuclear Medicine is a modality that has been growing a lot in Brazil and in the world, bringing new radiopharmaceuticals and technologies for the diagnosis and treatment of diseases, making them more effective and accurate. In the development of new radiopharmaceuticals for use in positron emission tomography (PET), the preclinical studies step largely uses PET scanners dedicated to small animals. To achieve this, quality control tests must be carried out to ensure the efficiency of the equipment. Thus, this work aimed to evaluate the spatial resolution of the small animals PET scanner of the CDTN using the isotope 68Ga. In this sense, a microPET hot rod phantom and a commercial 68Ge/68Ga generator were used to obtain PET images. The analysis of the 68Ga-PET images of the simulator was carried out qualitatively and quantitatively and revealed that the spatial resolution of the system using the 68Ga is 3.5 mm.
20 December 2022 in Brazilian Journal of Radiation Sciences
Small animals, such as mice, are used in radiopharmaceutical biodistribution studies and innumerous others preclinical investigations involving ionizing radiation. Longitudinal preclinical studies with five or more image procedures, involving radiopharmaceuticals injection and/or X-radiation, are not uncommon. However, a suitable dosimetric evaluation is not always available and, sometimes, absorbed doses in animal organs or tissues and their influence in experimental results were not appropriately taken into account. Accurate calculation of absorbed doses in mice organs are needed to evaluate potential radiobiological effects that may interfere with in vivo experiments. In this work, we perform a preliminary 16α-[18F]-fluoro-17β-estradiol (18F-FES) radiation dosimetry estimates for female mice. The obtained animal dosimetric results can be useful for evaluating animal doses during the design of longitudinal preclinical studies.
10 January 2024 in Brazilian Journal of Radiation Sciences
VMVictória Garcia Moreira
Normalization is a step taken to correct variations in count rates between detection channels of small animals PET scanners. In general, in laboratory practice, normalization is performed using a commercial source of germanium 68. Given the half-life of the Ge-68 isotope, the normalization source must be replaced every two years at most, which generates a significant spent for the Laboratory. The objective of this work was to develop and test an alternative rechargeable source to be used on normalization routine. The results indicated that the rechargeable source (18F-FDG) can be used to replace the commercial source.
5 July 2024 in Brazilian Journal of Radiation Sciences
The Centro de Desenvolvimento da Tecnologia Nuclear has a small animals positron emission tomograph in its Laboratório de Imagem Molecular. This equipment, the GE HealthCare LabPET SOLO 4 model, is widely used in preclinical studies related to the development of new radiopharmaceuticals or novel applications of conventional radiopharmaceuticals. The “PET Image Quality” subproject, integrated into the Centro de Desenvolvimento da Tecnologia Nuclear multi-year planning for 2018-2022, proposed actions involving quality assurance and human resources development for the laboratory. This work aims to consolidate the historical trajectory of Quality Assurance at Laboratório de Imagem Molecular of the Centro de Desenvolvimento da Tecnologia Nuclear. A search for documents related to the laboratory was conducted in the institutional quality system, called d-Qualidade, while a search for the curricula vitae of laboratory researchers was performed on the Plataforma Lattes, with the purpose of identifying the main products generated related to the Quality theme in the laboratory. The scientific production of the laboratory team demonstrates its pioneering role in Brazil in developing studies about the Quality Management applied to the small animals positron emission tomogragh. The laboratory history in the field of Quality Management emphasizes its national prominence and reveals the group's commitment over the past decade to significant technical/scientific production.