30 April 2021 in Brazilian Journal of Radiation Sciences
GSGuilherme Cavalcante de Albuquerque Souza
Guilherme Cavalcante de Albuquerque Souza
Positron emission tomography (PET) is an important molecular image modality and its application on preclinical research has increased during last decades. Thus, in laboratory practice, it is important to implement a quality control of the equipment, since intrinsic factors influence the image quality. The objective of this work was to perform and implement spatial resolution tests for the small animal PET scanner of the Molecular Imaging Laboratory, LIM/CDTN. Empirically, spatial resolution of a PET scanner can be determined from the measurement of point or linear sources and FWHM (full width half maximum) analysis of the respective linear profiles. In this work, a point source of 22Na and a hot rod style phantom filled with 18F-FDG solution were used. Acquisition and reconstruction of images were performed with the LabPET 1.12.1 software, provided by the equipment manufacturer. Image reconstruction parameters followed the LIM standard protocol: MLEM-3D algorithm, 20 iterations, no high resolution mode, no attenuation or scatter corrections, no post-filtering. PeakFit® and Amide softwares were used to perform images post-processing. The results indicate that the scanner has an adequate spatial resolution and its value is compatible with values reported in international studies performed on similar equipments.
18 September 2022 in Brazilian Journal of Radiation Sciences
JSJuliana Batista da Silva
This study aimed to evaluate the general performance of the preclinical PET scanner (LabPET Solo 4, GE) at CDTN/CNEN using the NEMA NU 4-2008 protocol. The performance parameters include: (i) spatial resolution; (ii) scatter fraction and counts rate performance; (iii) sensitivity and (iv) image quality. For the evaluation specific simulators and a sealed radioactive source of Sodium-22 were used. The results revealed that the NEMA-based radial spatial resolution ranged from 1.79 mm at the center of the FOV to 2.49 mm at a radial offset of 25mm. Tangential resolution ranged from 1.95mm at the center of the FOV to 3.50mm at a radial offset of 25mm. Axial resolution ranged from 1.78mm at the center of the FOV to 5.42mm at a radial offset of 25mm. Iterative image reconstruction improved the radial spatial resolution to 0.93mm at the center of the FOV. For the mouse-sized phantom, the peak noise equivalent count rate (NECR) was 37.8kcps at 85MBq whereas the peak true count rate was 169.9kcps at 125MBq with a count loss of 7.8% for the maximum rate reached at 103.3MBq. The peak of sensitivity (S) and absolute sensitivity (SA) at the center of axial field-of-view (FOV) is 5.7cps.Bq-1 and 0.63%, respectively. The overall imaging capabilities of the scanner were assessed using the NEMA image-quality phantom. The image roughness was 9.5%. Spillover rates (SORs) in air and in water were 0.26 and 0.17 respectively. The recovery coefficients (RCs) were 0.12 for the 1-mm-diameter rod and 0.91 for the 5-mm-diameter rod. The results demonstrate that CDTN/CNENsmall animal PET scanner has adequate reliability and acquired images are compatible with international quality standards for the molecular imaging research.
30 June 2020 in Brazilian Journal of Radiation Sciences
This work aims to evaluate the quality control program for small animal PET (positron emission tomography) scanners in Brazil. A questionnaire focused on type of small animal PET scanner and quality assurance program was prepared and sent to all Brazilian preclinical molecular imaging services that participated in the first Brazilian microPET/SPECT/CT users meeting held at the Federal University of Rio de Janeiro. The answers were compiled and descriptive statistic was applied. There are six preclinical molecular imaging services using PET scanner in Brazil. Five are in the southeastern region and one in the southern region. All services have a single PET device, but most of them have hybrids modalities with CT (computed tomography) and/or SPECT (single photon emission computed tomography). All services have knowledge of the NEMA NU 4-2008 publication specific to small animal PET equipments. However, most of them do not have a quality assurance program in place for their imaging systems. There are few preclinical PET devices installed in Brazil and most of them are located at southeastern region. Regardless the absence of quality assurance program in many of the services, there is a consensus on the importance of quality control program implementation.
31 October 2023 in Brazilian Journal of Radiation Sciences
CBCarlos Alberto Buchpiguel
Carlos Alberto Buchpiguel
+3
This study evaluated Image Quality (IQ) parameters and spatial resolution (SR) of Triumph® LabPET systems installed in three different Brazilian preclinical molecular imaging centers. A comprehensive evaluation of the PET scanner intrinsic parameters is important to optimize the acquired images, providing more reliable qualitative and quantitative analyses. Experiments were carried out at the centers: C1 - Molecular Imaging Laboratory of the CDTN/CNEN; C2 - Laboratory of Nuclear Medicine of HCFMUSP; C3 - Preclinical Research Center of the Brain Institute at PUC-RS. IQ phantom PET images were acquired as recommended in NEMA NU 4-2008 standard. Image reconstructions were performed in each system using the same reconstruction protocol. Data was processed using PMOD® software. The IQ parameters: (i) uniformity, (ii) spill-over ratio (SOR) and (iii) recovery coefficients (RC) were evaluated and compared. For Uniformity test, the percentage standard deviations of mean activity concentration were 7.8%; 7.3% and 6.4% for Centers 1, 2 and 3 respectively. Cold chambers RSO values in the systems 1, 2 and 3 were respectively 0.16, 0.19 and 0.21 for water; 0.26; 0.28 and 0.30 for air. The RC’s for rod diameters from 1 to 5 mm ranged from 0.08 to 0.91 for the three centers. Results revealed that the three PET systems have appropriate quality parameters for pre-clinical studies, presenting values compatible with international standards. This study was able to reveals the performance of preclinical PET system of different Brazilian imaging centers and may support the standardization of a National Quality Control Program for Small Animal PET scanners.
4 December 2022 in Brazilian Journal of Radiation Sciences
In Brazil, currently there are six preclinical molecular imaging centers and seven different small animal PET systems in use. However, there is still no national specific legislation for research laboratories focused on preclinical molecular images, unlike clinical nuclear medicine centers. A standardization of quality control protocols is needed to harmonize the use of small animal PET scanners in the research field. Thus, the aim of this work was to propose a National Program for Quality Control (NPQC) for the preclinical PET imaging systems in Brazil. This work was based on the quality control tests performed in Molecular Image Laboratory LIM/CDTN based on NEMA NU 4-2008 as described and presented in doctoral thesis of GONTIJO, 2019. The proposal of the NQCP was based on the CNEN NN 3.05 Publication (2013) and includes fundamental tests to be adopted, if possible, in laboratory practice to corroborate the experimental data. The Quality Control Program implemented in LIM/CDTN is an innovative and unprecedented proposal in the scope of preclinical molecular imaging services in Brazil. Therefore, the LIM/CDTN Program was carried out as a pilot to evidence the applicability and viability of the NQCP using small animal PET scanners. Summarizing, this work presents a viable set of Quality Control tests and their periodicities like a proposal for standardization to harmonize the use of this imaging technology in the field of research. Therefore, a National Quality Control Program (NQCP) applied to small animal PET scanners.
5 July 2024 in Brazilian Journal of Radiation Sciences
The Centro de Desenvolvimento da Tecnologia Nuclear has a small animals positron emission tomograph in its Laboratório de Imagem Molecular. This equipment, the GE HealthCare LabPET SOLO 4 model, is widely used in preclinical studies related to the development of new radiopharmaceuticals or novel applications of conventional radiopharmaceuticals. The “PET Image Quality” subproject, integrated into the Centro de Desenvolvimento da Tecnologia Nuclear multi-year planning for 2018-2022, proposed actions involving quality assurance and human resources development for the laboratory. This work aims to consolidate the historical trajectory of Quality Assurance at Laboratório de Imagem Molecular of the Centro de Desenvolvimento da Tecnologia Nuclear. A search for documents related to the laboratory was conducted in the institutional quality system, called d-Qualidade, while a search for the curricula vitae of laboratory researchers was performed on the Plataforma Lattes, with the purpose of identifying the main products generated related to the Quality theme in the laboratory. The scientific production of the laboratory team demonstrates its pioneering role in Brazil in developing studies about the Quality Management applied to the small animals positron emission tomogragh. The laboratory history in the field of Quality Management emphasizes its national prominence and reveals the group's commitment over the past decade to significant technical/scientific production.