2 August 2010 in Journal of Esthetic and Restorative Dentistry
LSLetícia Oliveira Saraiva
GNGetúlio DA Rocha Nogueira‐Filho
Getúlio DA Rocha Nogueira‐Filho
1 January 2013 in Contemporary Clinical Dentistry
LSLetíciaoliveria Saraiva
TAThaianeRodrigues Aguiar
LCLourenço Correr-Sobrinho
Aim: The aim of this study was to investigate the effect of phosphoric acid etching and the dentin pre-treatment with sodium hypochlorite (NaOCl) on the push-out bond strength between fiber post and root canal dentin. Materials and Methods: Root canals of 48 human incisors were selected, post spaces were prepared and assigned to four groups: G1-37% phosphoric acid (15 s); G2-5.25% NaOCl (2 min) +37% phosphoric acid (15 s); G3-37% phosphoric acid (60 s); and G4-5.25% NaOCl (2 min) +37% phosphoric acid (60 s). Fiber post cementation was performed with two-step etch-and-rinse adhesive system/dual-cured resin cement according to the manufacturer's recommendation. After 24 h, each root was sectioned transversally into three slices (cervical, middle and apical) and the bond strength of each section was determined using a push-out bond strength test. Morphology analysis of the bonded interface was evaluated using a scanning electron microscopy. Push-out strength data (MPa) were analyzed by Analysis of Variance and Tukey-Kramer (α = 0.05). Results: Considering the NaOCl pre-treatment, no statistically significant differences were observed among groups; however, when the phosphoric acid was applied during 60 s in the apical portion without NaOCl pre-treatment, the bond strength was statistically significant increased. Conclusion: The NaOCl pre-treatment did not improve the bond strength of adhesive luting cement to root canal dentin. The findings suggest that the use of 37% phosphoric acid for 60 s may have a beneficial effect on bond strength in the apical root third.
1 September 2004 in Journal of Applied Oral Science
ACAndrea Nóbrega Cavalcanti
Andrea Nóbrega Cavalcanti
The purpose of the present study was to evaluate the microleakage at the composite-repair interface using different bonding systems. Composite resin specimens (Filtek Z250 - 3M-ESPE) were divided into five groups (n=20) according to the following bonding mechanism: C - control - etching with 35% phosphoric acid; SB1 - etching and application of one coat of Single Bond (3M-ESPE); SB2 - etching and application of two coats of Single Bond (3M-ESPE); SMP1 - etching, application of Scotchbond Multi-Purpose primer (3M-ESPE) followed by the adhesive and, SMP2 - etching, application of Scotchbond Multi-Purpose adhesive (3M-ESPE) without the primer. Thereafter, all groups received new resin application. Samples were thermocycled (500 cycles / 5ºC - 55ºC [±2]) and immersed for 4h in 2% methylene blue buffered dye solution (7.0 pH). Three examiners measured the extent of microleakage in a stereoscope microscope, using four representative scores. For all experimental groups, no significant difference in microleakage at the repair was identified by Kruskal-Wallis test (p > 0.05). Therefore, different types of bonding systems presented the same effect on the dye penetration along the repair interface.
1 September 2016 in Operative Dentistry
SUMMARY: Purpose: The aim of this study was to evaluate the effect of low-thickness ceramic laminate translucency on water sorption and solubility in resin luting agents. Methods and Materials: Ceramic slides (15×0.7 mm) were generated using lithium disilicate (IPS e.max Press, Ivoclar-Vivadent, Schaan, Liechtenstein) that were A1 in color and had decreasing degrees of translucency (high, medium, and low). A slide of transparent glass of similar size was used as the control. Under each slide, 15 specimens (8×0.5 mm) of differing composite materials from the same manufacturer (3M ESPE Dental Products, St Paul, MN, USA) were prepared (n=5): light-cured resin cement (RelyX Veneer); dual-cured resin cement (RelyX ARC); and flowable composite (Z350XT Flow). To evaluate the loss or gain of mass, the specimens were dried until a constant mass was reached. Then, they were immersed in water for seven days and weighed immediately following removal from water. Subsequently, the specimens were dried again until a constant mass was obtained. The mass measurements were used to calculate the water sorption and solubility. Statistical analyses were carried out using a two-way analysis of variance and the Tukey test. Results: Under the high-translucency ceramic slides, all of the luting agents showed similar performance regarding water sorption; the flowable composite resin and the light-cured resin cement had the lowest solubility values. Under the medium- and low-translucency surfaces, the dual-cured resin cement and the flowable composite resin showed better performance with respect to water sorption and solubility. Conclusions: In the case of high-translucency laminates, luting agents with different activation methods might be used. However, even in thin sections, decreasing the translucency of the laminate led to significant loss of light penetration, indicating a decreased likelihood of the physical activation of the resin cement.
14 March 2014 in Journal of Esthetic and Restorative Dentistry