Liashuk Vitalij

Liashuk Vitalij

Auto-generated profile, based on publicly available information

Liashuk Vitalij

Dnipropetrovsk National University of Railway Transport named after academician V. Lazaryan,Department of intelligent power supply systems,Dnipro,Ukraine

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2020
Verified
Conference Paper
Closed access
SVSychenko Viktor
Sychenko Viktor
DODanylov Oleksiy
Danylov Oleksiy
BPBekh Petro
Bekh Petro
KYKosariev Yevhen
Kosariev Yevhen
LVLiashuk Vitalij
Liashuk Vitalij
TDTanya Drubetskaya
Tanya Drubetskaya
Modern requirements for the traction power supply system of direct current in providing the high-speed movement are reduced to the need of ensuring a normalized voltage level of 2900 V on current collectors of electric locomotives. At the same time, the power supply system has to be stable on changes in power consumption and have the necessary specific energy intensity. The purpose of the work is to explain the transition to a new circuit design of the traction network using additional generators of electric energy. The proposed asymmetrical power supply system of the electric rolling stock allows to provide the required voltage level on the electric locomotive current collectors, to reduce the range of its changes and to reduce the power losses by 14.3% compared to the symmetrical centralized power supply circuit design with passive boosting of the traction network.

1 May 2020
Verified
Conference Paper
Closed access
SVSychenko Viktor
Sychenko Viktor
AAAndrii Antonov
Andrii Antonov
LVLiashuk Vitalij
Liashuk Vitalij
RNRudevich Nataliia
Rudevich Nataliia
BDBelukhin Dmitry
Belukhin Dmitry
BVBozhko Vladimir
Bozhko Vladimir
The puprose of the work is to improve approaches to the controllability of power consumption in distributed power systems of electric rolling stock using modern technologies and equipment. Unequal energy consumption on the shoulders of the power supply causes additional losses in the system and makes the voltage mode worse on the current collectors of electric locomotives. To increase the controllability of operation modes, is proposed to use feeder volt-additional converters with arcless commutation of short-circuit currents. Using such converters allow to stabilize the voltage on the current collectors of electric locomotives and reduce the switching-off time. Variant calculations using the proposed circuit engineering of traction substations on the simulation model prove that the power losses from the equalizing currents are significantly reduced