24 April 2019 in IEEE Transactions on Power Delivery
Replacing the Phase Shifting Transformers (PSTs) of Interphase Power Controller (IPC) with a reduced rating dual Unified Power Flow Controller (UPFC) results in a Unified Interphase Power Controller (UIPC) with potential for enhanced performance. However, in most cases, the UPFC is controlled as a Static Phase Shifter (SPS), producing marginal improvements. A control approach that allows the minimization of the power ratings of the series Voltage Source Converters (VSCs) of the UIPC was recently proposed. For that, one has to define four control parameters, as opposed to only two in the SPS-based UIPC. This can be done off-line, by means of an optimization procedure that splits the desired transmission line current among the capacitive and inductive branches of the UIPC. In this paper, a control scheme is presented for the implementation of the novel technique. The current sharing factors obtained from the optimization are stored in a lookup table. The gating signals for the VSCs are generated using Park's transformation so as to synthesize the optimal UIPC inductive and capacitive branch currents with Proportional Resonant (PR) controllers and Sinusoidal Pulse-Width Modulation (SPWM). The transmission line angle, as well as the magnitude and phase of the desired transmission line current with respect to the voltage at the receiving end voltage, are assumed to be provided by a Transmission System Operator (TSO). Experimental results that include steady-state and transient conditions are provided to prove its feasibility.
1 August 2017 in Canadian Journal of Electrical and Computer Engineering
The basic interphase power controller (IPC) presents the interesting features of simplicity and low cost but is less flexible than most flexible ac transmission system controllers. A compromise performance can be achieved by replacing the phase shifting transformers with a reduced rating dual unified power flow controller (UPFC) resulting in a unified IPC. The comparison of the basic, phase shifter-based, with a new UPFC-based, control logic is the main goal of this paper. The control variables of the dual UPFC are computed based on an optimization procedure to minimize a given cost function. The results show the higher capability of the proposed logic not only to control the current flow through the transmission line but also to achieve this task with lower branch currents that should lead to reduced power losses.
22 September 2026 in Estudios Geológicos
In the Moroccan cement industry, searching for alternatives to clinker using noncalcined mineral additions has become a significant focus to reduce energy consumption and greenhouse gas emissions and produce cement with a low environmental impact. This study examines the effects of incorporating Triassic basalts and Liassic limestone on the mechanical properties of mortars, as well as cement color, water demand, setting time, and durability of cement – based composites. The pozzolanic activity of basalt, calculated from chemical composition and amorphous phase content, is proposed as an intrinsic index of pozzolanic activity. The pozzolanic activity strength index was evaluated as the ratio of the compressive strength of the blended basalt – limenstone/cement mortar to that of a control Portland cement. Mortars with 10–15% of El Hajeb basalt and 19–24% limestone exhibited optimal mechanical performance at early (2 d) and long-term (28 d) stages, while improving setting times. Additionally, these combinations offer improved environmental and economic benefits for the production of pozzolanic CEMIV and CEMII composite cements, which comply with international standards (ASTM C618, 2022; EN 197-5, 2021; and NM 10, 01, 004, 2019).