Yuexuan Lou

Yuexuan Lou

Auto-generated profile, based on publicly available information

Yuexuan Lou

School of Electrical Engineering and Automation, Harbin Institute of Technology, Harbin, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 October 2024 in Energies
Verified
Journal Article
Open access
PDF file
YLYuexuan Lou
Yuexuan Lou
HZHe Zhang
He Zhang
Lu ZhangLu Zhang
Lu Zhang
HCHaoran Cai
Haoran Cai
With the advancement of manufacturing, the precision requirements for various high-precision processing equipment and instruments have further increased. Due to its noncontact nature, simple structure, and controllable performance, electromagnetic levitation has broad application prospects in ultra-precision instruments and ground testing of aerospace equipment. Research on vibration isolation technology using electromagnetic levitation is imperative. This paper reviews the latest research achievements of three types of passive isolators and five active isolation actuators. It also summarizes the current research status of analytical methods for passive isolators and the impact of isolator layout. This study explores current isolators’ achievements, such as the development of passive isolators that generate negative stiffness and require mechanical springs for uniaxial translational vibrations, single-function actuators, and control systems focused on position and motion vibration control. Based on the current isolators’ characteristics, this review highlights future developments, including focusing on passive isolators for heavy loads and multi-axis isolation, addressing complex vibrations, including rotational ones, and developing methods to calculate forces and torques for arbitrary six-DOF movements while improving speed. Additionally, it emphasizes the importance of multifunctional actuators to simplify system structures and comprehensive control systems that consider more environmental factors. This provides significant reference value for vibration isolation technology using electromagnetic levitation.

12 November 2024 in Actuators
Verified
Journal Article
Open access
PDF file
YLYuexuan Lou
Yuexuan Lou
HZHe Zhang
He Zhang
HCHaoran Cai
Haoran Cai
Magnetic springs, which can be used to replace traditional mechanical springs, have many advantages, such as necessitating no physical contact, generating no friction, no vibration or noise, and having a long lifespan. Nevertheless, their strong nonlinearity limits their widespread application. In this study, we developed a novel permanent magnet spring to address this issue: a Halbach permanent magnetic spring, with a large levitation force and an approximately linear force characteristic curve. First, we introduce the structure and the parameters of the Halbach permanent magnetic spring. Second, we describe the levitation force performance and the stiffness performance of the Halbach permanent magnetic spring using finite element analysis. Third, we analyze the trends through which different parameters influence the levitation force performance and stiffness performance. Finally, we provide recommendations for the future design of and improvement in the Halbach permanent magnetic spring.

1 April 2026 in IEEE/ASME Transactions on Mechatronics
Verified
Journal Article
Closed access
HLHao Lu
Hao Lu
BKBaoquan Kou
Baoquan Kou
Changchuang HuangChangchuang Huang
Changchuang Huang
YLYuexuan Lou
Yuexuan Lou
HZHaoquan Zhang
Haoquan Zhang
Lu ZhangLu Zhang
Lu Zhang
The electrodynamic suspension (EDS) is one of the representatives of the maglev system, which is expected to realize high-speed transportation. In this article, an electromagnetic model of a Halbach permanent magnet array (HPMA) and null-flux-coil (NFC) is established based on a permanent magnet EDS (PMEDS) system. First, the electromagnetic analysis model of the PMEDS system is established by the Biot–Savart Law and the dynamic loop theorem. Subsequently, the comprehensive sensitivity analysis of the electromagnetic parameters of the PMEDS is carried out, and the influence factors of different variables are obtained. The optimization objectives are determined by the levitation drag ratio, levitation mass ratio, average levitation force, and levitation force ripple. Furthermore, the optimization is carried out based on NSGA-II. Then, finite element analysis is used to verify the effectiveness of the optimization results. Next, the rationality of the optimization method is verified by a static experiment. Moreover, the reliability of the optimization results is confirmed through dynamic performance analysis. Finally, the optimal pole pitch ratio of HPMA-NFC is proposed to achieve a lower electromagnetic force ripple. Results show that the optimized parameters enhance the performance of PMEDS within the controllable cost range and provide guidance for engineering applications.

13 March 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
YLYuexuan Lou
Yuexuan Lou
HZHe Zhang
He Zhang
HCHaoran Cai
Haoran Cai
RYRunze Yang
Runze Yang
To levitate ultraprecision instruments and largescale aerospace equipment, gravity compensators need to provide greater levitation forces. The realization of such forces is hindered by mechanical structural constraints. Concurrently, the low speed of existing modeling methods makes repetitive calculations for compensators with multiple permanent magnets challenging. To address these two challenges, a novel magnetic levitation gravity compensator topology and a rapid modeling method are introduced. For the topology, finite element method simulations are employed to investigate its performance. For the modeling method, the magnetic field strength contributions from permanent magnets at various positions relative to the target are initially assessed. The computation process is subsequently accelerated by limiting the number of permanent magnets considered. Additionally, various trade-offs between speed and precision are evaluated. Ultimately, a prototype is fabricated and subjected to experiments to validate the new topology and modeling method. According to the simulation results, the new topology can effectively increase the achievable levitation force to 14,180.84 N without being limited by mechanical structural constraints. Additionally, a stiffness of 15.88 N/mm is obtained. Moreover, the novel modeling method significantly reduces the calculation time, with only minor decreases in accuracy. Even the maximum errors are merely 1.33% and 1.23%. The calculation time is reduced by 52.18% and 86.66%. Finally, the topology’s performance and the modeling method’s effectiveness are validated experimentally.

3 November 2025 in IEEE Transactions on Aerospace and Electronic Systems
Verified
Journal Article
Closed access
YLYuexuan Lou
Yuexuan Lou
HZHe Zhang
He Zhang
HCHaoran Cai
Haoran Cai
The complexity of motion in real-world scenarios may introduce parasitic torque to the operation of gravity compensators. When confronted with such disturbances, classic compensator topologies will generate a torque that exacerbates the detrimental effects of these disturbances. Simultaneously, an effective analytical method is absent to precisely calculate the interactions between permanent magnets in the presence of both translational and deflection states in space. To address these two issues, an anti-deflection gravity compensator topology has been proposed to generate a restorative torque, effectively suppressing disturbances when deflection occurs in any given axis, and an improved equivalent magnetic charge method was introduced to calculate the forces and torques between inclined permanent magnets. Initially, the origin of parasitic torque generation in classic topology is analyzed. Subsequently, the performances of this topology across different axes are analyzed. Furthermore, the specific mathematical model for the proposed developed analytical method is presented, and two examples are provided to validate the effectiveness of the analytical method. The maximum error along the x-axis and z-axis is only 1.37 N and 0.16 N. Finally, a prototype of the anti-deflection compensator is fabricated and tested. The experimental results verifies the performances and anti-deflection capabilities of the topology. They also affirm the accuracy of the proposed analytical method.