Teresa Nolte

Teresa Nolte

Auto-generated profile, based on publicly available information

Teresa Nolte

Department of Diagnostic and Interventional Radiology, University Hospital RWTH Aachen, Aachen, Germany

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2023 in Radiology
Verified
Journal Article
Closed access
GMGustav Müller-Franzes
Gustav Müller-Franzes
LHLuisa Huck
Luisa Huck
...... ....
.... ....
FKFiras Khader
Firas Khader
THTianyu Han
Tianyu Han
DTDaniel Truhn
Daniel Truhn
Background Reducing the amount of contrast agent needed for contrast-enhanced breast MRI is desirable. Purpose To investigate if generative adversarial networks (GANs) can recover contrast-enhanced breast MRI scans from unenhanced images and virtual low-contrast-enhanced images. Materials and Methods In this retrospective study of breast MRI performed from January 2010 to December 2019, simulated low-contrast images were produced by adding virtual noise to the existing contrast-enhanced images. GANs were then trained to recover the contrast-enhanced images from the simulated low-contrast images (approach A) or from the unenhanced T1- and T2-weighted images (approach B). Two experienced radiologists were tasked with distinguishing between real and synthesized contrast-enhanced images using both approaches. Image appearance and conspicuity of enhancing lesions on the real versus synthesized contrast-enhanced images were independently compared and rated on a five-point Likert scale. P values were calculated by using bootstrapping. Results A total of 9751 breast MRI examinations from 5086 patients (mean age, 56 years ± 10 [SD]) were included. Readers who were blinded to the nature of the images could not distinguish real from synthetic contrast-enhanced images (average accuracy of differentiation: approach A, 52 of 100; approach B, 61 of 100). The test set included images with and without enhancing lesions (29 enhancing masses and 21 nonmass enhancement; 50 total). When readers who were not blinded compared the appearance of the real versus synthetic contrast-enhanced images side by side, approach A image ratings were significantly higher than those of approach B (mean rating, 4.6 ± 0.1 vs 3.0 ± 0.2; P < .001), with the noninferiority margin met by synthetic images from approach A (P < .001) but not B (P > .99). Conclusion Generative adversarial networks may be useful to enable breast MRI with reduced contrast agent dose. © RSNA, 2023 Supplemental material is available for this article. See also the editorial by Bahl in this issue.

1 August 2021 in Biomaterials
Verified
Journal Article
Closed access
VPVertika Pathak
Vertika Pathak
TNTeresa Nolte
Teresa Nolte
ERElena Rama
Elena Rama
ARAnne Rix
Anne Rix
SDSeyed Mohammadali Dadfar
Seyed Mohammadali Dadfar
Fabian KiesslingFabian Kiessling
Fabian Kiessling

1 January 2024 in Radiology: Artificial Intelligence
Verified
Journal Article
Closed access
...... ....
.... ....
MLMahshad Lotfinia
Mahshad Lotfinia
TNTeresa Nolte
Teresa Nolte
MSMarwin-Jonathan Sähn
Marwin-Jonathan Sähn
PIPeter Isfort
Peter Isfort
DTDaniel Truhn
Daniel Truhn
To investigate the integration of differential privacy (DP) and analyze its impact on model performance as compared with models trained without DP. Leveraging more than 590 000 chest radiographs from five institutions, including VinDr-CXR from Vietnam, ChestX-ray14 and CheXpert from the United States, UKA-CXR from Germany, and PadChest from Spain, the authors evaluated the efficacy of DP-enhanced domain transfer (DP-DT) in classifying cardiomegaly, pleural effusion, pneumonia, atelectasis, and healthy individuals. Diagnostic performance and sex-specific and age-specific demographic fairness of DP-DT and of non–DP-DT models were compared using the area under the receiver operating characteristic curve (AUC) as the main metric, as well as accuracy, sensitivity, and specificity as secondary metrics, and evaluated for statistical significance using paired Student t tests. Even with high privacy levels (ε ≈ 1), DP-DT showed no evidence of differences compared with non–DP-DT in terms of a decrease in AUC of cross-institutional performance as compared with single-institutional performance (VinDr-CXR: 0.07 vs 0.07, P = .96; ChestX-ray14: 0.07 vs 0.06, P = .12; CheXpert: 0.07 vs 0.07, P = .18; UKA-CXR: 0.18 vs 0.18, P = .90; and PadChest: 0.07 vs 0.07, P = .35). Furthermore, AUC differences between DP-DT and non–DP-DT models were less than 1% for all sex subgroups (P > .33 for female and P > .22 for male, for all domains) and nearly all age subgroups (P > .16 for younger participants, P > .33 for adults, and P > .27 for older adults, for nearly all domains). Cross-institutional performance of artificial intelligence models was not affected by DP. Keywords: Convolutional Neural Network (CNN), Transfer Learning, Supervised Learning, Diagnosis, Forensics, Computer Applications–General, Image Postprocessing, Informatics, Neural Networks, Thorax, Computer-Aided Diagnosis, Deep Learning, Domain Transfer, Differential Privacy, Privacy-Preserving AI, Chest Radiograph Supplemental material is available for this article. © RSNA, 2023 See also the commentary by Suri and Summers in this issue.

21 October 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
TNTeresa Nolte
Teresa Nolte
NGNicolas Gross‐Weege
Nicolas Gross‐Weege
MDMariya Doneva
Mariya Doneva
PKPeter Koken
Peter Koken
AEAaldert Elevelt
Aaldert Elevelt
VSVolkmar Schulz
Volkmar Schulz
Purpose: Magnetic resonance fingerprinting (MRF) with spiral readout enables rapid quantification of tissue relaxation times. However, it is prone to blurring because of off‐resonance effects. Hence, fat blurring into adjacent regions might prevent identification of small tumors by their quantitative T1 and T2 values. This study aims to correct for the blurring artifacts, thereby enabling fast quantitative mapping in the female breast.Methods: The impact of fat blurring on spiral MRF results was first assessed by simulations. Then, MRF was combined with 3‐point Dixon water–fat separation and spiral blurring correction based on conjugate phase reconstruction. The approach was assessed in phantom experiments and compared to Cartesian reference measurements, namely inversion recovery (IR), multi‐echo spin echo (MESE), and Cartesian MRF, by normalized root‐mean‐square error (NRMSE) and SD calculations. Feasibility is further demonstrated in vivo for quantitative breast measurements of 6 healthy female volunteers, age range 24–31 y.Results: In the phantom experiment, the blurring correction reduced the NRMSE per phantom vial on average from 16% to 8% for T1 and from 18% to 11% for T2 when comparing spiral MRF to IR/MESE sequences. When comparing to Cartesian MRF, the NRMSE reduced from 15% to 8% for T1 and from 12% to 7% for T2. Furthermore, SDs decreased. In vivo, the blurring correction removed fat bias on T1/T2 from a rim of ~7–8 mm width adjacent to fatty structures.Conclusion: The blurring correction for spiral MRF yields improved quantitative maps in the presence of water and fat.

1 January 2023 in Science Progress
Verified
Journal Article
Open access
KLKim Lindelauf
Kim Lindelauf
Athul ThomasAthul Thomas
Athul Thomas
MBMarco Baragona
Marco Baragona
AJAli Jouni
Ali Jouni
TNTeresa Nolte
Teresa Nolte
ARAndreas Ritter
Andreas Ritter
Electroporation (EP) is widely used in medicine, such as cancer treatment, in form of electrochemotherapy or irreversible electroporation (IRE). For EP device testing, living cells or tissue inside a living organism (including animals) are needed. Plant-based models seem to be a promising alternative to substitute animal models in research. The aim of this study is to find a suitable plant-based model for visual evaluation of IRE, and to compare the geometry of electroporated areas with in-vivo animal data. For this purpose, a variety of fruit and vegetables were selected and visually evaluated after 0/1/2/4/6/8/12/16/24 h post-EP. Apple and potato were found to be suitable models as they enabled a visual evaluation of the electroporated area. For these models, the size of the electroporated area was determined after 0/1/2/4/6/8/12/16/24 h. For apples, a well-defined electroporated area was visual within two hours, while in potatoes it reached a plateau after eight hours only. The electroporated area of apple, which showed the fastest visual results was then compared to a retrospectively evaluated swine liver IRE dataset which had been obtained for similar conditions. The electroporated area of the apple and swine liver both showed a spherical geometry of comparable size. For all experiments, the standard protocol for human liver IRE was followed. To conclude, potato and apple were found to be suitable plant-based models for the visual evaluation of electroporated area after irreversible EP, with apple being the best choice for fast visual results. Given the comparable range, the size of the electroporated area of the apple may be promising as a quantitative predictor in animal tissue. Even if plant-based models cannot completely replace animal experiments, they can be used in the early stages of EP device development and testing, decreasing animal experiments to the necessary minimum.

11 March 2022 in Diagnostics
Verified
Journal Article
Open access
PDF file
GMGustav Müller-Franzes
Gustav Müller-Franzes
TNTeresa Nolte
Teresa Nolte
MCMalin Ciba
Malin Ciba
JSJustus Schock
Justus Schock
FKFiras Khader
Firas Khader
DTDaniel Truhn
Daniel Truhn
For T2 mapping, the underlying mono-exponential signal decay is traditionally quantified by non-linear Least-Squares Estimation (LSE) curve fitting, which is prone to outliers and computationally expensive. This study aimed to validate a fully connected neural network (NN) to estimate T2 relaxation times and to assess its performance versus LSE fitting methods. To this end, the NN was trained and tested in silico on a synthetic dataset of 75 million signal decays. Its quantification error was comparatively evaluated against three LSE methods, i.e., traditional methods without any modification, with an offset, and one with noise correction. Following in-situ acquisition of T2 maps in seven human cadaveric knee joint specimens at high and low signal-to-noise ratios, the NN and LSE methods were used to estimate the T2 relaxation times of the manually segmented patellofemoral cartilage. In-silico modeling at low signal-to-noise ratio indicated significantly lower quantification error for the NN (by medians of 6–33%) than for the LSE methods (p < 0.001). These results were confirmed by the in-situ measurements (medians of 10–35%). T2 quantification by the NN took only 4 s, which was faster than the LSE methods (28–43 s). In conclusion, NNs provide fast, accurate, and robust quantification of T2 relaxation times.