Yuchen Suo

Yuchen Suo

Auto-generated profile, based on publicly available information

Yuchen Suo

School of Instrumentation Science and Optoelectronics Engineering, Beihang University, Beijing, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 November 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
TLTengyue Long
Tengyue Long
Xinda SongXinda Song
Xinda Song
BHBangcheng Han
Bangcheng Han
YSYuchen Suo
Yuchen Suo
LJLe Jia
Le Jia
In this study, we demonstrate a three-axis synchronous sweeping field (TSSF) method for in situ magnetic field compensation under three-axis nonorthogonal conditions for optically pumped magnetometers (OPMs). The OPM operated in the spin-exchange relaxation-free (SERF) regime is gaining popularity as a promising substitute for the superconducting quantum interference device (SQUID) in biomagnetism measurements. Nevertheless, the three-axis nonorthogonality inherent in the OPM will give rise to residual magnetic field inaccuracies along the pumping axis while conducting the in situ magnetic field compensation procedure, consequently introducing supplementary OPM errors. The TSSF method can more proficiently rectify the residual magnetic field along the pumping axis and suppress the corresponding errors. In contrast to traditional methods, the TSSF method diminishes both the rotation angles of the sensitive axis and dual-axis coupling coefficients, which are introduced through compensation errors along the pumping axis, by more than 80%, and improves the measurement sensitivities by more than 30%. This effective magnetic field compensation method of the OPM holds promise for further improving the performance of OPM. It is expected to enhance the localization and calibration accuracy of multiple-channel OPM-based magnetoencephalography (OPM-MEG) systems.

8 December 2023 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
TLTengyue Long
Tengyue Long
Xinda SongXinda Song
Xinda Song
ZDZhaoxin Duan
Zhaoxin Duan
YSYuchen Suo
Yuchen Suo
ZWZhendong Wu
Zhendong Wu
BHBangcheng Han
Bangcheng Han
Optically pumped magnetometer (OPM) has gained popularity as a viable alternative to the superconducting quantum interference device (SQUID) for biomagnetic measurements. However, the presence of amplitude and phase errors in the OPM can degrade the signal quality of, e.g., magnetoencephalography (MEG) signals. This study presents a dual-PI closed-loop control (DPCC) method aimed at suppressing amplitude and phase errors of the OPM when operated in the spin-exchange relaxation-free (SERF) regime, thereby enhancing MEG localization accuracy. The main sources of the amplitude and phase errors in the OPM are identified through a theoretical analysis of the inertial element characteristics and static residual magnetic fields. The experimental results demonstrate that the utilization of DPCC for the OPM reduces the amplitude and phase errors in static MEG measurements by 94.2% and 95.6%, respectively. At a residual magnetic field of 6.5 nT, the amplitude and phase errors are further suppressed by 97.8% and 87.2%, respectively. Furthermore, the fluctuation of the residual magnetic field is reduced by a factor of 25, significantly enhancing the robustness of the OPM. This straightforward and effective arrangement of the OPM holds promise in the field of biomagnetism and is expected to enhance the localization and calibration accuracy of OPM-based MEG (OPM-MEG) systems.