8 November 2023 in IEEE Transactions on Instrumentation and Measurement
In this study, we demonstrate a three-axis synchronous sweeping field (TSSF) method for in situ magnetic field compensation under three-axis nonorthogonal conditions for optically pumped magnetometers (OPMs). The OPM operated in the spin-exchange relaxation-free (SERF) regime is gaining popularity as a promising substitute for the superconducting quantum interference device (SQUID) in biomagnetism measurements. Nevertheless, the three-axis nonorthogonality inherent in the OPM will give rise to residual magnetic field inaccuracies along the pumping axis while conducting the in situ magnetic field compensation procedure, consequently introducing supplementary OPM errors. The TSSF method can more proficiently rectify the residual magnetic field along the pumping axis and suppress the corresponding errors. In contrast to traditional methods, the TSSF method diminishes both the rotation angles of the sensitive axis and dual-axis coupling coefficients, which are introduced through compensation errors along the pumping axis, by more than 80%, and improves the measurement sensitivities by more than 30%. This effective magnetic field compensation method of the OPM holds promise for further improving the performance of OPM. It is expected to enhance the localization and calibration accuracy of multiple-channel OPM-based magnetoencephalography (OPM-MEG) systems.
8 December 2023 in IEEE Transactions on Instrumentation and Measurement
Optically pumped magnetometer (OPM) has gained popularity as a viable alternative to the superconducting quantum interference device (SQUID) for biomagnetic measurements. However, the presence of amplitude and phase errors in the OPM can degrade the signal quality of, e.g., magnetoencephalography (MEG) signals. This study presents a dual-PI closed-loop control (DPCC) method aimed at suppressing amplitude and phase errors of the OPM when operated in the spin-exchange relaxation-free (SERF) regime, thereby enhancing MEG localization accuracy. The main sources of the amplitude and phase errors in the OPM are identified through a theoretical analysis of the inertial element characteristics and static residual magnetic fields. The experimental results demonstrate that the utilization of DPCC for the OPM reduces the amplitude and phase errors in static MEG measurements by 94.2% and 95.6%, respectively. At a residual magnetic field of 6.5 nT, the amplitude and phase errors are further suppressed by 97.8% and 87.2%, respectively. Furthermore, the fluctuation of the residual magnetic field is reduced by a factor of 25, significantly enhancing the robustness of the OPM. This straightforward and effective arrangement of the OPM holds promise in the field of biomagnetism and is expected to enhance the localization and calibration accuracy of OPM-based MEG (OPM-MEG) systems.
3 February 2024 in Measurement
9 December 2024 in IEEE Sensors Journal
Magnetoencephalography (MEG), leveraging magnetic signal detection, is a clinically validated neuroimaging technique known for its high spatiotemporal resolution and non-invasive nature, effectively mitigating damage to brain function and mortality rates in preoperative epilepsy evaluations. Optically pumped magnetometer (OPM), a quantum sensor, emerges as the new generation of MEG detection device benefiting from its low cost, wearable, motion robustness, and lifespan-compliant. While in the context of medical applications, the OPM-MEG system requires overcoming several barriers. Magnetic field interference has the propensity to impact the OPM, triggering output errors and thus diminish the quality of neuromagnetic imaging. In this review, we thoroughly explore the advantages and limitations of hardware-based magnetic field interference suppression techniques, and envision the implementable suppression strategies focusing on the pressing demand for the mobile MEG. The anticipated iterative enhancements in magnetic field interference suppression technology hold the promise of driving the application of OPM-MEG in more naturalistic, multi-person interactive paradigms in cognitive neuroscience, thus facilitating the development of novel therapeutic approaches for neurological and psychiatric disorders.
23 May 2023 in Metrologia
The currently employed algorithms for the magnetic field compensation of single-beam spin-exchange relaxation-free atomic magnetometers are excessively slow and unstable, which limits the use and commercialization of magnetometer arrays for biological magnetic measurement. This study proposes an improved trisection algorithm (ITSA) to compensate for the magnetic field around the vapor cell in an attempt to resolve these limitations. Through the constant monitoring of the intensity of light emitted from a laser, the proposed algorithm reduces the time required to compensate for magnetic fields to 0.85 s in a single magnetometer, which is nine times faster than the traditional algorithm, and to 26 s in 36-channel magnetoencephalography equipment, which is 15.5 times faster than the traditional algorithm. In addition, an approximately 16% increase in measuring sensitivities is achieved based on the ITSA compared with the traditional algorithm. These improvements can promote the usage efficiency and commercialization of biological magnetic measurement instruments. Furthermore, the ITSA is verified using an experimental setup and the mathematical analysis and comparable experimental results demonstrate the effectiveness of the proposed algorithm.
9 January 2025 in IEEE Transactions on Instrumentation and Measurement
Aiming at the issue of substantial nonlinear error arising from triaxial DC magnetic field interferences in wearable and mobile measurement scenarios, a triaxial magnetic fields response model of single-beam atomic SERF magnetometer under non-zero magnetic condition is established, revealing that the effect of triaxial DC magnetic field interferences on the detected AC responses exhibits the nonlinear feature, while their impact on the DC response manifests as the interval-linear characteristic. Consequently, a closed-loop control system for mixed AC and DC magnetic fields is proposed. By leveraging the DC response within the feedback signal, a localized linearization control strategy is implemented across the triaxial magnetic fields, enabling direct and real-time suppression of DC interferences, and subsequently reducing their nonlinear impact on the measured AC response. Among them, the nonlinear impact caused by x-axis DC magnetic field interference decreases from 48.12% in the open-loop configuration to 0.01%. Additionally, it takes less time to suppress the interferences to below 2%, shortened from 4.7 s to 32 ms.