A new dual-layer multi-leaf collimator (MLC) system with several improved characteristics was introduced with the Varian Halcyon™ treatment platform. This study evaluated this new MLC’s impact on head and neck plan quality and delivery efficiency. Nine patients were retrospectively studied with Institutional Review Board (IRB) approval. To compare plan quality between the Halcyon dual-layer MLC and Truebeam® MLC, all patients were replanned with the same prescription and target coverage following the institutional clinical protocol for both platforms and using both intensity modulated radiation therapy (IMRT) or volumetrically modulated arc therapy (VMAT) techniques. Organs-at-risk (OAR) dose-volume histogram (DVH) statistics were compared along with total plan monitor units (MU). To evaluate delivery efficiency, actual beam-on time for five patients’ plans were recorded and compared. To evaluate the impact of MLC performance parameters on plan quality, virtual MLC models were generated by matching Truebeam MLC’s parameters to those of the Halcyon dual-layer MLC both individually and combined. OAR doses were then compared between these virtual MLCs, the Truebeam MLC, and the actual Halcyon MLC. Overall the Halcyon dual-layer MLC provided similar plan quality compared to Truebeam MLC for VMAT plans, and improved sparing for majority of the OARs when using IMRT. Paired comparison showed median dose differences in mean doses to the parotids, cochlea, esophagus, and larynx ranged from -0.83 Gy to 0.37 Gy for VMAT, and from -4.79 Gy to -0.04 Gy for IMRT, with negative values indicating improved performance by Halcyon. Despite a slight increase in plan MU, the Halcyon reduced the total beam-on time by 42.8 ± 8.5%. Virtual MLC simulations demonstrated that matching MLC transmission accounted for nearly half of the total dose difference between Halcyon and Truebeam IMRT plans. When compared to the Truebeam, the Halcyon’s dual-layer MLC achieved similar plan quality using VMAT, and improved OAR sparing using IMRT, while providing nearly twice as fast treatment delivery. Reduction in MLC transmission is the dominating factor contributing to dosimetric differences in OAR sparing.
We conducted a phase I dose-escalation trial of radiation with ipilimumab in patients with melanoma with ≥2 metastatic lesions. Here, we report the final full clinical analysis. Patients received RT (6 or 8 Gy x 2 or 3 doses) to a single lesion followed by 4 cycles of ipilimumab. The primary endpoint was maximum tolerated dose of RT, and secondary endpoint was response at non-radiated sites. Twenty-two patients with treatment-naïve (n = 11) or treatment-refractory (n = 11) Stage IV melanoma were enrolled. There were 31 treatment-related adverse events (AEs), of which 16 were deemed immune-related. Eleven patients had grade 3 AEs (no grade 4/5). There were no dose-limiting toxicities related to the radiation/ipilimumab combination. Five of 22 patients (22.7%, 95% CI 7.8–45.4%) had partial response as best response and three (13.6%) had stable disease. Median overall survival was 10.7 months (95% CI, 4.9 months to not-estimable) and median progression-free survival 3.6 months (95% CI, 2.9 months to 7.8 months). Seven patients were still alive at the time of last follow-up (median follow-up 89.2 months), most of whom received pembrolizumab after progression. Radiotherapy followed by ipilimumab was well tolerated and yielded a response rate that compares favorably to the objective response rate with ipilimumab alone. Furthermore, 32% of patients are long-term survivors, most of whom received pembrolizumab. Based on these results, the recommended dose that was used in subsequent Phase 2 trials was 8 Gy x 3 doses. Clinical Trial Registration: NCT01497808 (www.clinicaltrials.gov)
Objective: To evaluate dosimetric consequences of inter-fraction setup variation and anatomical changes in patients receiving multifield optimised (MFO) intensity modulated proton therapy for post-operative oropharyngeal (OPC) and oral cavity (OCC) cancers. Methods: Six patients receiving MFO for post-operative OPC and OCC were evaluated. Plans were robustly optimised to clinical target volumes (CTVs) using 3 mm setup and 3.5% range uncertainty. Weekly online cone beam CT (CBCT) were performed. Planning CT was deformed to the CBCT to create virtual CTs (vCTs) on which the planned dose was recalculated. vCT plan robustness was evaluated using a setup uncertainty of 1.5 mm and range uncertainty of 3.5%. Target coverage, D95%, and hotspots, D0.03cc, were evaluated for each uncertainty along with the vCT-calculated nominal plan. Mean dose to organs at risk (OARs) for the vCT-calculated nominal plan and relative % change in weight from baseline were evaluated. Results: Robustly optimised plans in post-operative OPC and OCC patients are robust against inter-fraction setup variations and range uncertainty. D0.03cc in the vCT-calculated nominal plans were clinically acceptable across all plans. Across all patients D95% in the vCT-calculated nominal treatment plan was at least 100% of the prescribed dose. No patients lost ≥10% weight from baseline. Mean dose to the OARs and max dose to the spinal cord remained within tolerance. Conclusion: MFO plans in post-operative OPC and OCC patients are robust to inter-fraction uncertainties in setup and range when evaluated over multiple CT scans without compromising OAR mean dose. Advances in knowledge: This is the first paper to evaluate inter-fraction MFO plan robustness in post-operative head and neck treatment.