Guanda Xu

Guanda Xu

Auto-generated profile, based on publicly available information

Guanda Xu

National Key Laboratory of Electromagnetic Energy, Naval University of Engineering, Wuhan, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 September 2023 in IEEE Transactions on Transportation Electrification
Verified
Journal Article
Closed access
GXGuanda Xu
Guanda Xu
FXFei Xiao
Fei Xiao
CLChuanqiang Lian
Chuanqiang Lian
This article aims to provide a more credible control scheme or a fault-tolerant control strategy for permanent magnet synchronous motor (PMSM) drives without a position sensor. Considering that, a position sensorless control strategy is proposed using only one phase current sensor. First, the mathematical model of full-order sliding mode observer (FSMO) is established in the stationary reference frame. Second, the coordinate transformation and notch filter (NF) are carried out for the only measurable phase current to calculate the current error information, which is needed by the FSMO. Third, a phase-locked loop (PLL) is employed to estimate the position. The motor parameter variation effect on the position estimation is evaluated. The observer’s stability and parameter design method are analyzed through the Lyapunov theory. The proposed method utilizes a single current sensor to reconstruct the three-phase current and position signals, which improves the economy of inverters and provides the possibility of fault-tolerant control with few sensors. Compared with existing methods, it is simpler to implement and does not require changing the power unit structure. Finally, experiments have shown that the proposed method is comparable to the full-current-sensor method in terms of position estimation and control performance. Compared to the traditional method, the proposed method has higher accuracy of position estimation and better dynamic and steady-state control performance.

23 October 2024 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
CLChuanqiang Lian
Chuanqiang Lian
LGLiYuan Guo
LiYuan Guo
GXGuanDa Xu
GuanDa Xu
FXFei Xiao
Fei Xiao
RWRuitian Wang
Ruitian Wang
WZWeiwei Zhang
Weiwei Zhang
The dual three-phase permanent magnet synchronous motor (DTP-PMSM) has wide applications in fields such as wind power generation, electric vehicles, and flywheel energy storage. Reducing the current harmonics of the DTP-PMSM is beneficial for enhancing operational efficiency, diminishing noise and vibration, and improving electromagnetic compatibility, which is of significant importance for boosting the overall performance of the system. This article focuses on the current harmonic minimum pulse width modulation (CHMPWM) for the surface-mounted DTP-PMSM with a 3L-NPC inverter and an output filter. Based on the system model, the relationship between the switching angles and the harmonic current of the motor is derived, and the mathematical model of CHMPWM is established. Furthermore, the optimal switching angles that minimize the current harmonics can be obtained by solving the established optimization problem. The proposed CHMPWM takes into account the effect of filter and motor parameters on the current harmonic characteristics, which is the main difference from the conventional CHMPWM. Simulation and experimental studies were conducted on a 1 MW/40MJ flywheel energy storage system, and the results show that compared to sine PWM and space vector PWM, the current harmonics of the proposed CHMPWM are reduced by more than 40% on average. Compared to the conventional CHMPWM, the proposed CHMPWM further reduces the current harmonics by more than 20% on average and exhibits good robustness to motor parameters.

31 July 2025 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
GXGuanda Xu
Guanda Xu
FXFei Xiao
Fei Xiao
CLChuanqiang Lian
Chuanqiang Lian
JLJilong Liu
Jilong Liu
WZWeiwei Zhang
Weiwei Zhang
The high-frequency (HF) pulsating carrier voltage injection method is widely used for sensorless control of permanent magnet synchronous motors operating in the low-speed region. In this method, the position error contained in the q-axis current amplitude is typically extracted using a combination of a band-pass filter and a low-pass filter (LPF). However, the position estimation loop of this strategy faces the problem of being unable to balance dynamic performance and steady-state accuracy, thus limiting the overall control performance. This article proposes an improved position error signal extraction strategy based on an all-pass filter (APF). First, the HF current signal is delayed by 1/4 of the injection cycle through the APF. Second, fast extraction of the rotor position error can be realized by coordinate transformation. The proposed scheme eliminates the requirement for a LPF while enhancing both the speed and accuracy of position error extraction. Crucially, under typical operating conditions, it achieves an 80% reduction in dynamic settling time while maintaining identical steady-state accuracy requirements compared to conventional methods during demodulated signal amplitude extraction. Experimental results show that compared with some existing methods, the proposed method has better dynamic performance under working conditions such as speed reversal, speed step, and torque step, and its effectiveness has been verified.