Daniel A. Enderich

Daniel A. Enderich

Auto-generated profile, based on publicly available information

Daniel A. Enderich

Air Force Research Laboratory Directed Energy Directorate, Kirtland Air Force Base, Albuquerque, NM, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
BHBrad W. Hoff
Brad W. Hoff
JMJeremy W. McConaha
Jeremy W. McConaha
ZCZane W. Cohick
Zane W. Cohick
MFMatthew A. Franzi
Matthew A. Franzi
DEDaniel A. Enderich
Daniel A. Enderich
SPSteven Perini
Steven Perini
A set of three apparatus enabling RF exposure of aerosolized pathogens at four chosen frequencies (2.8 GHz, 4.0 GHz, 5.6 GHz, and 7.5 GHz) has been designed, simulated, fabricated, and tested. Each apparatus was intended to operate at high power without leakage of RF into the local environment and to be compact enough to fit within biocontainment enclosures required for elevated biosafety levels. Predictions for the range of RF electric field exposure, represented by the complex electric field vector magnitude, that an aerosol stream would be expected to encounter while passing through the apparatus are calculated for each of the chosen operating frequencies.

17 August 2022 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
BHBrad W. Hoff
Brad W. Hoff
ZCZane W. Cohick
Zane W. Cohick
BTBurt S. Tilley
Burt S. Tilley
JLJohn W. Luginsland
John W. Luginsland
DRDavid Revelli
David Revelli
DSDonald A. Shiffler
Donald A. Shiffler
Objective: The purpose of the present study is to investigate the inactivation of bioaerosols containing Bovine Coronavirus, BCov, under repetitively pulsed radio frequency (RF) electromagnetic exposure. Methods: These experiments were performed in a waveguide containing a flowing aerosol stream and were limited to a single RF waveform: ∼2 μs square envelope, 5.6 GHz, 4.8 kHz repetition rate. Aerosol streams were exposed to RF electric field amplitudes in the range of 41.9 +/- 6.2 kV/m. Under laminar flow conditions, 75% of the total collected aerosol stream spends 0.85 seconds or less in the RF exposure region. Results: Application of the RF waveform changes mean survival rate of the aerosolized BCov by -0.58 decades (roughly a 74% reduction) and impacted the variance and standard deviation of the experimental results, with the RF exposure data showing an 800% increase in variance and 196% increase in standard deviation over the control results. Experimental results were compared to those from an analytic electromagnetic-heating inactivation model. Conclusion: The comparison indicated the feasibility that the observed reduction in BCov survival rate might be due to a combination of thermal effects and non-thermal electric field effects. Significance: Developing better insight into the mechanisms of inactivation is important for understanding the potential limits of efficacy for this method. Additionally, these results contribute an important baseline for the impact of electromagnetic fields on aerosolized pathogens.

1 June 2021 in Review of Scientific Instruments
Verified
Journal Article
Closed access
PDF file
DEDaniel A. Enderich
Daniel A. Enderich
BHBrad W. Hoff
Brad W. Hoff
MGMichael Geiler
Michael Geiler
AGAnton Geiler
Anton Geiler
COCasey Ottesen
Casey Ottesen
HIHammad Irshad
Hammad Irshad
A system capable of exposing a flowing aerosol stream to short duration (2–4 ns), high-power RF waveforms is described. The system utilizes a C-band gyromagnetic nonlinear transmission line source having peak power outputs ranging as high as 80 kW at a center frequency of 4.2 GHz. RF electric field magnitudes of up to 280 kV/m ± 17% are achieved within the aerosol flow region of the RF exposure apparatus.

31 March 2023 in IEEE Transactions on Plasma Science
Verified
Journal Article
Closed access
RMR. Bruce Miller
R. Bruce Miller
HTHenry Trujillo
Henry Trujillo
RJRichard W. Johnson
Richard W. Johnson
AAAndrey D Andreev
Andrey D Andreev
DSDon Smith
Don Smith
MLMichael R. Lambrecht
Michael R. Lambrecht
A lightweight, portable 15 MeV electron beam linear accelerator (LINAC) system has been developed for research applications. Our approach uses a commercial, off-the-shelf magnetron to drive an S-band standing-wave accelerator. The magnetron is driven by a Type-E pulse forming network (PFN), the modulator, switched with a thyratron. Within the modulator macropulse, short ( $<$ 100 ns), high-frequency (up to 3500 Hz) electron beam pulses are produced by gating the electron current from a triode electron gun. The entire system is contained within approximately 2 m $^{3}$ , weighs 250 kg, and can be disassembled into two person-portable components, each weighing 50 kg or less.