The configuration of beam–column joints in precast concrete (PC) building structures varies widely, and different connection methods significantly affect the progressive collapse resistance of the structure. This study investigates the progressive collapse resistance of an innovative beam–column connection node frame. Finite element models of four-story, two-span space frame structures made of reinforced concrete (RC) and PC were developed using ANSYS 14.0/LS-DYNA R5.x software, employing nonlinear dynamic and static analysis to examine structural collapse behavior under bottom middle or corner column damage. Numerical results indicate that following the failure of the middle or corner column due to explosion loading, the vertical displacement and collapse rate of the PC structure with the novel connection method are less than those of the RC structure during collapse progression. Furthermore, upon removal of the middle or corner column, the residual load-carrying capacity of the PC structure with the innovative connection increased by 7% and 3.7%, respectively, compared to the RC structure. This suggests that PC structures with this type of connection demonstrate superior performance in resisting progressive collapse, offering valuable insights for future engineering applications.
27 February 2022 in Mathematical Problems in Engineering
This paper presents an overlapping decentralized guaranteed cost hybrid control method for adjacent buildings with uncertain parameters, by combining the guaranteed cost control algorithm with the overlapping decentralized control strategy. The passive dampers are used as link members between the two parallel buildings, and the active control devices are installed between two consecutive floors in two adjacent buildings. The passive coupling dampers modulate the relative responses between the two buildings, and the active control devices modulate the interstory responses of each building. Based on the inclusion principle, a large-scale structure is divided into a set of paired substructures with common parts first. Then, the controller of each pair of substructures is designed by using the guaranteed cost algorithm. After that, the controller of the original system is formed by using the contraction principle. Consequently, the proposed approach is used to prevent pounding damage and achieve the best results in earthquake response reduction of uncertain adjacent buildings when compared with the calculation results obtained by the centralized control strategy. Furthermore, the stability and reliability of the control system are promoted by adopting the overlapping decentralized control strategy.