Nobuyuki Tanaka

Nobuyuki Tanaka

Auto-generated profile, based on publicly available information

Nobuyuki Tanaka

Center for Biosystems Dynamics Research (BDR), RIKEN, Kobe, Hyogo, Japan

Research Focus & Metrics

Academic Career Length

34Years (1993-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 May 2019 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NTNobuyuki Tanaka
Nobuyuki Tanaka
TKTakeshi Kogo
Takeshi Kogo
NHNobumitsu Hirai
Nobumitsu Hirai
Akiko OgawaAkiko Ogawa
Akiko Ogawa
Hideyuki KanematsuHideyuki Kanematsu
Hideyuki Kanematsu
YTYo Tanaka
Yo Tanaka
A biofilm has a unique structure composed of microorganisms, extracellular polymeric substances (EPSs), etc., and it is layered on a substrate in water. In material science, it is important to detect the biofilm formed on a surface to prevent biofouling. EPSs, the major component of the biofilm, mainly consist of polysaccharides, proteins, nucleic acids, and lipids. Because these biomolecules have a variety of hydrophilicities or hydrophobicities, the substrate covered with the biofilm shows different wettability from the initial state. To detect the biofilm formation, this study employed a liquid-squeezing-based wettability assessment method with a simple wettability index: the liquid-squeezed diameter of a smaller value indicates higher wettability. The method is based on the liquid-squeezing behaviour of a liquid that covers sample surfaces when an air-jet is applied. To form the biofilm, polystyrene surfaces were immersed and incubated in a water-circulated bioreactor that had collected microorganisms in ambient air. After the 14-d incubation, good formation of the biofilm on the surfaces was confirmed by staining with crystal violet. Although the contact angles of captive bubbles on the surfaces with the biofilm were unmeasurable, the liquid-squeezing method could distinguish between hydrophilic and hydrophobic initial surfaces with and without biofilm formation using the diameter of the liquid-squeezed area. The surface wettability is expected to be a promising property for in-situ detection of biofilm formation on a macroscopic scale.

21 December 2017 in Scientific Reports
Verified
Journal Article
Open access
PDF file
DPDavid G. Priest
David G. Priest
NTNobuyuki Tanaka
Nobuyuki Tanaka
YTYo Tanaka
Yo Tanaka
YTYuichi Taniguchi
Yuichi Taniguchi
High-throughput microscopy of bacterial cells elucidated fundamental cellular processes including cellular heterogeneity and cell division homeostasis. Polydimethylsiloxane (PDMS)-based microfluidic devices provide advantages including precise positioning of cells and throughput, however device fabrication is time-consuming and requires specialised skills. Agarose pads are a popular alternative, however cells often clump together, which hinders single cell quantitation. Here, we imprint agarose pads with micro-patterned ‘capsules’, to trap individual cells and ‘lines’, to direct cellular growth outwards in a straight line. We implement this micro-patterning into multi-pad devices called CapsuleHotel and LineHotel for high-throughput imaging. CapsuleHotel provides ~65,000 capsule structures per mm2 that isolate individual Escherichia coli cells. In contrast, LineHotel provides ~300 line structures per mm that direct growth of micro-colonies. With CapsuleHotel, a quantitative single cell dataset of ~10,000 cells across 24 samples can be acquired and analysed in under 1 hour. LineHotel allows tracking growth of > 10 micro-colonies across 24 samples simultaneously for up to 4 generations. These easy-to-use devices can be provided in kit format, and will accelerate discoveries in diverse fields ranging from microbiology to systems and synthetic biology.

1 October 2020 in Lab on a Chip
Verified
Journal Article
Open access
PDF file
YSYigang Shen
Yigang Shen
Yaxiaer YalikunYaxiaer Yalikun
Yaxiaer Yalikun
YAYusufu Aishan
Yusufu Aishan
NTNobuyuki Tanaka
Nobuyuki Tanaka
ASAsako Sato
Asako Sato
YTYo Tanaka
Yo Tanaka
A flexible manipulation platform combines microheaters and an area cooling system to position and manipulate single particles and cells.

1 August 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
NTNobuyuki Tanaka
Nobuyuki Tanaka
TYTadahiro Yamashita
Tadahiro Yamashita
Yaxiaer YalikunYaxiaer Yalikun
Yaxiaer Yalikun
SASatoshi Amaya
Satoshi Amaya
ASAsako Sato
Asako Sato
YTYo Tanaka
Yo Tanaka

27 November 2023 in IEEE Transactions on Automation Science and Engineering
Verified
Journal Article
Closed access
JZJunbo Zhang
Junbo Zhang
Weiwei WanWeiwei Wan
Weiwei Wan
NTNobuyuki Tanaka
Nobuyuki Tanaka
MFMiki Fujita
Miki Fujita
KTKoichi Takahashi
Koichi Takahashi
Kensuke HaradaKensuke Harada
Kensuke Harada
This paper presents a system integration approach for a 6-DoF (Degree of Freedom) collaborative robot to operate a pipette for liquid dispensing. Its technical development is three-fold. First, we designed an end-effector for holding and triggering manual pipettes. Second, we took advantage of direct teaching to specify global labware poses and planned robotic motion based on them. Third, we leveraged hand-mounted cameras and visual classifiers to predict and correct positioning errors, which allowed precisely attaching pipettes and tips without calibration. Through experiments and analysis, we confirmed that the developed system, especially the planning and visual recognition methods, could help secure high-precision and flexible liquid dispensing. The developed system is suitable for low-frequency, high-repetition biochemical liquid dispensing tasks. We expect it to promote the deployment of collaborative robots for laboratory automation and thus improve the experimental efficiency without significantly customizing a laboratory environment. Note to Practitioners —The proposed system helps to automate low-frequency, high-repetition biochemical experiments using a vertical articulated robot with uncalibrated hand-mounted cameras and TCP (Tool Center Point). It can be quickly deployed in tight lab spaces or beside existing automation instruments for experiments. Implementing the system does not require high-quality cameras or precise manufacturing. The system relies on software, particularly vision compensation, and the flexibility provided by unfixed racks to successfully perform pipetting tasks. We particularly recommend using collaborative robots to implement the proposed system. Collaborative robots typically meet safety requirements and do not need to be enclosed in a cage. This allows them to be deployed in the same workspace as human researchers, enabling efficient lab experiments. Human researchers can prepare tips and microwell plates and place them in front of the robot with a certain degree of freedom, which is less burdensome than traditional automatic devices that require precise placement of tips and plates in specified positions. Practitioners can view an example of the robot working with a plant phenotyping system for screening chemicals in the supplementary video.

31 May 2017 in The Astrophysical Journal
Verified
Journal Article
Open access
PDF file
TMT. Mizuno
T. Mizuno
NTN. Tanaka
N. Tanaka
HTH. Takahashi
H. Takahashi
JKJ. Katsuta
J. Katsuta
KHK. Hayashi
K. Hayashi
RYR. Yamazaki
R. Yamazaki
This article reports the results of X-ray studies of the extended TeV γ-ray source VER J2019+368. Suzaku observations conducted to examine properties of the X-ray pulsar wind nebula (PWN) around PSR J2021+3651 revealed that the western region of the X-ray PWN has a source extent of with the major axis oriented to that of the TeV emission. The PWN-west spectrum was closely fitted by a power law for absorption at and a photon index of , with no obvious change in the index within the X-ray PWN. The measured X-ray absorption indicates that the distance to the source is much less than the inferred by radio data. Aside from the PWN, no extended emission was observed around PSR J2021+3651 even by Suzaku. Archival data from the XMM-Newton were also analyzed to complement the Suzaku observations, indicating that the eastern region of the X-ray PWN has a similar spectrum ( and ) and source extent up to at least along the major axis. The lack of significant change in the photon index and the source extent in X-ray are used to constrain the advection velocity or the diffusion coefficient for accelerated X-ray-producing electrons. A mean magnetic field of is required to account for the measured X-ray spectrum and reported TeV γ-ray spectrum. A model calculation of synchrotron radiation and inverse Compton scattering was able to explain of the reported TeV flux, indicating that the X-ray PWN is a major contributor of VER J2019+368.