Baichuan Jiang

Baichuan Jiang

Auto-generated profile, based on publicly available information

Baichuan Jiang

Johns Hopkins University, Department of Computer Science, Baltimore, Maryland, United States

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
HSHyunwoo Song
Hyunwoo Song
HMHamid Moradi
Hamid Moradi
BJBaichuan Jiang
Baichuan Jiang
KXKeshuai Xu
Keshuai Xu
YWYixuan Wu
Yixuan Wu
EBEmad M. Boctor
Emad M. Boctor
This letter introduces the first integrated real-time intraoperative surgical guidance system, in which an endoscope camera of da Vinci surgical robot and a transrectal ultrasound (TRUS) transducer are co-registered using photoacoustic markers that are detected in both fluorescence (FL) and photoacoustic (PA) imaging. The co-registered system enables the TRUS transducer to track the laser spot illuminated by a pulsed-laser-diode attached to the surgical instrument, providing both FL and PA images of the surgical region-of-interest (ROI). As a result, the generated photoacoustic marker is visualized and localized in the da Vinci endoscopic FL images, and the corresponding tracking can be conducted by rotating the TRUS transducer to display the PA image of the marker. A quantitative evaluation revealed that the average registration and tracking errors were 0.84 mm and 1.16°, respectively. This study shows that the co-registered photoacoustic marker tracking can be effectively deployed intraoperatively using TRUS+PA imaging providing functional guidance of the surgical ROI.

27 September 2023 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
BJBaichuan Jiang
Baichuan Jiang
LWLiam Wang
Liam Wang
KXKeshuai Xu
Keshuai Xu
MHMartin Hossbach
Martin Hossbach
ADAlican Demir
Alican Demir
EBEmad M. Boctor
Emad M. Boctor
As one of the most commonly performed spinal interventions in routine clinical practice, lumbar punctures are usually done with only hand palpation and trial-and-error. Failures can prolong procedure time and introduce complications such as cerebrospinal fluid leaks and headaches. Therefore, an effective needle insertion guidance method is desired. In this work, we present a complete lumbar puncture guidance system with the integration of (1) a wearable mechatronic ultrasound imaging device, (2) volume-reconstruction and bone surface estimation algorithms and (3) two alternative augmented reality user interfaces for needle guidance, including a HoloLens-based and a tablet-based solution. We conducted a quantitative evaluation of the end-to-end navigation accuracy, which shows that our system can achieve an overall needle navigation accuracy of 2.83 mm and 2.76 mm for the Tablet-based and the HoloLens-based solutions, respectively. In addition, we conducted a preliminary user study to qualitatively evaluate the effectiveness and ergonomics of our system on lumbar phantoms. The results show that users were able to successfully reach the target in an average of 1.12 and 1.14 needle insertion attempts for Tablet-based and HoloLens-based systems, respectively, exhibiting the potential to reduce the failure rates of lumbar puncture procedures with the proposed lumbar-puncture guidance.

7 February 2018 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
BJBaichuan Jiang
Baichuan Jiang
WGWenpeng Gao
Wenpeng Gao
DKDaniel Kacher
Daniel Kacher
ENErez Nevo
Erez Nevo
BFBarry Fetics
Barry Fetics
JJJagadeesan Jayender
Jagadeesan Jayender

2 October 2016
Verified
Book Chapter
Closed access
PDF file
BJBaichuan Jiang
Baichuan Jiang
WGWenpeng Gao
Wenpeng Gao
DKDaniel F. Kacher
Daniel F. Kacher
TLThomas C. Lee
Thomas C. Lee
JJJagadeesan Jayender
Jagadeesan Jayender

11 November 2022 in arXiv
Verified
Preprint
Open access
PDF file
BJBaichuan Jiang
Baichuan Jiang
KXKeshuai Xu
Keshuai Xu
AMAhbay Moghekar
Ahbay Moghekar
PKPeter Kazanzides
Peter Kazanzides
EBEmad Boctor
Emad Boctor
Clear identification of bone structures is crucial for ultrasound-guided lumbar interventions, but it can be challenging due to the complex shapes of the self-shadowing vertebra anatomy and the extensive background speckle noise from the surrounding soft tissue structures. Therefore, we propose to use a patch-like wearable ultrasound solution to capture the reflective bone surfaces from multiple imaging angles and create 3D bone representations for interventional guidance. In this work, we will present our method for estimating the vertebra bone surfaces by using a spatiotemporal U-Net architecture learning from the B-Mode image and aggregated feature maps of hand-crafted filters. The methods are evaluated on spine phantom image data collected by our proposed miniaturized wearable "patch" ultrasound device, and the results show that a significant improvement on baseline method can be achieved with promising accuracy. Equipped with this surface estimation framework, our wearable ultrasound system can potentially provide intuitive and accurate interventional guidance for clinicians in augmented reality setting.

1 July 2025 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
BJBaichuan Jiang
Baichuan Jiang
Ernest GrahamErnest Graham
Ernest Graham
MUMathias Unberath
Mathias Unberath
RTRussell H. Taylor
Russell H. Taylor
RKRaymond C. Koehler
Raymond C. Koehler
EBEmad M. Boctor
Emad M. Boctor
Perinatal hypoxic-ischemic encephalopathy (HIE) is estimated to affect approximately one to three per 1000 live full-term births and can lead to severe neuropsychological sequelae or death. It was reported that ∼25% of the affected newborns will develop severe sequelae, including cerebral palsy, mental retardation, epilepsy, or increased hyperactivity, and 15% to 20% will die in the postnatal period.1