Emad M. Boctor

Emad M. Boctor

Auto-generated profile, based on publicly available information

Emad M. Boctor

Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Whiting School of Engineering, Baltimore, Maryland, USA

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 June 2022 in Photoacoustics
Verified
Journal Article
Open access
YWYixuan Wu
Yixuan Wu
Jeeun KangJeeun Kang
Jeeun Kang
WLWojciech Lesniak
Wojciech Lesniak
ALAla Lisok
Ala Lisok
HZHaichong Zhang
Haichong Zhang
EBEmad M. Boctor
Emad M. Boctor
This study presents a system-level optimization of spectroscopic photoacoustic (PA) imaging for prostate cancer (PCa) detection in three folds. First, we present a spectral unmixing model to segregate spectral system error (SSE). We constructed two noise models (NMs) for the laser spectrotemporal fluctuation and the ultrasound system noise. We used these NMs in linear spectral unmixing to denoise and to achieve high temporal resolution. Second, we employed a simulation-aided wavelength optimization to select the most effective subset of wavelengths. NMs again were considered so that selected wavelengths were not only robust to the collinearity of optical absorbance, but also to noise. Third, we quantified the effect of frame averaging on improving spectral unmixing accuracy through theoretical analysis and numerical validation. To validate the whole framework, we performed comprehensive studies in simulation and an in vivo experiment which evaluated prostate-specific membrane antigen (PSMA) expression in PCa on a mice model. Both simulation analysis and in vivo studies confirmed that the proposed framework significantly enhances image signal-to-noise ratio (SNR) and spectral unmixing accuracy. It enabled more sensitive and faster PCa detection. Moreover, the proposed framework can be generalized to other spectroscopic PA imaging studies for noise reduction, wavelength optimization, and higher temporal resolution.

5 January 2022 in Journal of Neural Engineering
Verified
Journal Article
Closed access
Jeeun KangJeeun Kang
Jeeun Kang
XLXiuyun Liu
Xiuyun Liu
SCSuyi Cao
Suyi Cao
SZSteven R Zeiler
Steven R Zeiler
EGErnest M Graham
Ernest M Graham
RKRaymond C Koehler
Raymond C Koehler
Objective: Perinatal ischemic stroke is estimated to occur in 1/2300–1/5000 live births, but early differential diagnosis from global hypoxia-ischemia is often difficult. In this study, we tested the ability of a hand-held transcranial photoacoustic (PA) imaging probe to non-invasively detect a focal photothrombotic stroke (PTS) within 2 h of stroke onset in a gyrencephalic piglet brain. Approach: About 17 stroke lesions of approximately 1 cm 2 area were introduced randomly in anterior or posterior cortex via the light/dye PTS technique in anesthetized neonatal piglets ( n = 11). The contralateral non-ischemic region served as control tissue for discrimination contrast for the PA hemoglobin metrics: oxygen saturation, total hemoglobin (tHb), and individual quantities of oxygenated and deoxygenated hemoglobin (HbO 2 and HbR). Main results: The PA-derived tissue oxygen saturation at 2 h yielded a significant separation between control and affected regions-of-interest ( p < 0.0001), which were well matched with 24 h post-stroke cerebral infarction confirmed in the triphenyltetrazolium chloride-stained image. The quantity of HbO 2 also displayed a significant contrast ( p = 0.021), whereas tHb and HbR did not. The analysis on receiver operating characteristic curves and multivariate data analysis also agreed with the results above. Significance: This study shows that a hand-held transcranial PA neuroimaging device can detect a regional thrombotic stroke in the cerebral cortex of a neonatal piglet. In particular, we conclude that the oxygen saturation metric can be used alone to identify regional stroke lesions. The lack of change in tHb may be related to arbitrary hand-held imaging configuration and/or entrapment of red blood cells within the thrombotic stroke.

18 July 2022 in IEEE Robotics and Automation Letters
Verified
Journal Article
Closed access
HSHyunwoo Song
Hyunwoo Song
HMHamid Moradi
Hamid Moradi
BJBaichuan Jiang
Baichuan Jiang
KXKeshuai Xu
Keshuai Xu
YWYixuan Wu
Yixuan Wu
EBEmad M. Boctor
Emad M. Boctor
This letter introduces the first integrated real-time intraoperative surgical guidance system, in which an endoscope camera of da Vinci surgical robot and a transrectal ultrasound (TRUS) transducer are co-registered using photoacoustic markers that are detected in both fluorescence (FL) and photoacoustic (PA) imaging. The co-registered system enables the TRUS transducer to track the laser spot illuminated by a pulsed-laser-diode attached to the surgical instrument, providing both FL and PA images of the surgical region-of-interest (ROI). As a result, the generated photoacoustic marker is visualized and localized in the da Vinci endoscopic FL images, and the corresponding tracking can be conducted by rotating the TRUS transducer to display the PA image of the marker. A quantitative evaluation revealed that the average registration and tracking errors were 0.84 mm and 1.16°, respectively. This study shows that the co-registered photoacoustic marker tracking can be effectively deployed intraoperatively using TRUS+PA imaging providing functional guidance of the surgical ROI.

27 September 2023 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Closed access
BJBaichuan Jiang
Baichuan Jiang
LWLiam Wang
Liam Wang
KXKeshuai Xu
Keshuai Xu
MHMartin Hossbach
Martin Hossbach
ADAlican Demir
Alican Demir
EBEmad M. Boctor
Emad M. Boctor
As one of the most commonly performed spinal interventions in routine clinical practice, lumbar punctures are usually done with only hand palpation and trial-and-error. Failures can prolong procedure time and introduce complications such as cerebrospinal fluid leaks and headaches. Therefore, an effective needle insertion guidance method is desired. In this work, we present a complete lumbar puncture guidance system with the integration of (1) a wearable mechatronic ultrasound imaging device, (2) volume-reconstruction and bone surface estimation algorithms and (3) two alternative augmented reality user interfaces for needle guidance, including a HoloLens-based and a tablet-based solution. We conducted a quantitative evaluation of the end-to-end navigation accuracy, which shows that our system can achieve an overall needle navigation accuracy of 2.83 mm and 2.76 mm for the Tablet-based and the HoloLens-based solutions, respectively. In addition, we conducted a preliminary user study to qualitatively evaluate the effectiveness and ergonomics of our system on lumbar phantoms. The results show that users were able to successfully reach the target in an average of 1.12 and 1.14 needle insertion attempts for Tablet-based and HoloLens-based systems, respectively, exhibiting the potential to reduce the failure rates of lumbar puncture procedures with the proposed lumbar-puncture guidance.

25 March 2022 in International Journal of Computer Assisted Radiology and Surgery
Verified
Journal Article
Closed access
PDF file
KXKeshuai Xu
Keshuai Xu
BJBaichuan Jiang
Baichuan Jiang
AMAbhay Moghekar
Abhay Moghekar
PKPeter Kazanzides
Peter Kazanzides
EBEmad Boctor
Emad Boctor

1 January 2010
Verified
Conference Paper
Closed access
PSPhilipp J Stolka
Philipp J Stolka
HKHyun-Jae Kang
Hyun-Jae Kang
MCMichael Choti
Michael Choti
EBEmad M Boctor
Emad M Boctor
Handheld 2D ultrasound is very useful for intra-operative imaging, but requires some reconstruction effort in order to create 3D US volumes, unless one is using large and expensive 3D US probes. Unlike common probe tracking approaches involving either global or local tracking algorithms (suffering from jitter and complexity or from drift), we propose to use a combination of local sensors to reconstruct the probe trajectory with multiple degrees of freedom. The presented sensors are very low-cost- optical mice and a Wii Remote - yet enable flexible 3D US acquisition with no global tracking overhead. The resulting trajectories are then used as input for a dynamically expanding, pixel-nearest-neighbor 3D US volume reconstruction.