Mochamad Choifin

Mochamad Choifin

Auto-generated profile, based on publicly available information

Mochamad Choifin

Universitas Maarif Hasyim Latif

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
31 March 2025 in Journal of Sustainability for Energy
Verified
Journal Article
Open access
PDF file
MCMochamad Choifin
Mochamad Choifin
Integrating solar and wind energy into grid-connected electric vehicle charging stations (EVCSs) offers a promising pathway toward sustainable mobility by reducing greenhouse gas emissions, decreasing dependence on fossil fuels, and alleviating stress on power grids. This study systematically reviewed recent advancement in hybrid solar-wind systems to shed light on their design optimization, energy management strategies, techno-economic feasibility, and environmental impact. The review was conducted as per PRISMA 2020 guidelines, utilizing major databases such as Scopus, Web of Science, IEEE Xplore, and ScienceDirect. A refined set of highly relevant studies from hundreds of screened publications was analysed, using standardized evaluation criteria to ensure comparability across different research outcomes. Findings indicated that grid-connected EVCS powered by hybrid renewable systems could enhance reliability, improve cost-effectiveness, and reduce substantial emissions. Advanced control techniques and energy management systems including artificial intelligence, fuzzy logic, and optimization algorithms have demonstrated effectiveness in improving operational efficiency, supporting integration with storage systems, and enabling vehicle-to-grid (V2G) functions. Nevertheless, there are challenges regarding scalability, limited real-world validation, and a lack of standardized performance metrics. EVCSs, based on renewable energy, hold strong potential for supporting sustainable transportation infrastructure; therefore, future research should focus on long-term field demonstrations to develop benchmark datasets, and explore practical business models for V2G integration in order to accelerate large-scale adoption.

13 September 2021 in EUREKA: Physics and Engineering
Verified
Journal Article
Open access
PDF file
DPDony Perdana
Dony Perdana
SASatworo Adiwidodo
Satworo Adiwidodo
MCMochamad Choifin
Mochamad Choifin
WWWigo Ardi Winarko
Wigo Ardi Winarko
This study investigates the effect of attracting and repels magnetic fields with the materials of vegetable oil in the form of a mixture of coconut oil and jatropha (B50) against the behavior of stability and characteristics of flame in the process of premixed burning. The fuel for a mixture of vegetable oil of 600 ml was filled into the boiler heated with a gas stove to be evaporated at a temperature of 300 °C and 3 bar pressure was kept constant was mixed with air from the compressor in the burner room. Then a flame was ignited at the end of the nozzle to form a diffusion flame, the flame formed was then given north (N) and south (S). The results showed that the flame speed of the attractive magnetic field was 52.22 cm/sec, the repulsive magnetic field was 50.49 cm/sec while without a magnetic field was 49.79 cm/sec. The increase in the laminar flame speed in the attractive magnetic field is caused by the electron spin becoming more energetic and due to the change in the spin of the hydrogen proton from para to ortho. The attractive magnetic field has the strongest effect on increasing the flame speed. This makes the flame more stable in the equivalency ratio range of 0.75–1.17 compared to without a magnetic field in the same equivalency ratio range. This was so because O2 where it is in nature of paramagnetic was pumped more crossing the flame from south to north poles whereas the heat brought by H2O in nature of diamagnetic was pumped more crossing north to south poles. Whereas on the repel magnetic field, it was hotter when brought by H2O pumped into the flame whereas O2 tended to be pumped going out of the flame. This caused the combustion in the flame was smaller and the reaction was not maximum. As a consequence, the laminar flame speed was more lacking and the reaction was not to the fullest. As a consequence, the laminar flame speed in the repel was fewer than the attract magnetic field

1 March 2026 in International Journal of Applied Power Engineering (IJAPE)
Verified
Journal Article
Open access
PDF file
MCMochamad Choifin
Mochamad Choifin
YTYuki Trisnoaji
Yuki Trisnoaji
Zainal ArifinZainal Arifin
Zainal Arifin
MMMochamad Subchan Mauludin
Mochamad Subchan Mauludin
MRMarsya Aulia Rizkita
Marsya Aulia Rizkita
DPDony Perdana
Dony Perdana
This study explores the techno-economic feasibility of integrating solar photovoltaic (PV) systems for electric vehicle (EV) charging infrastructure in Sidoarjo, Indonesia. Through simulation using HOMER Pro software, both standalone PV and PV-grid hybrid configurations were evaluated under real-world EV load profiles. The analysis reveals that the PV-grid hybrid system demonstrates superior economic performance, achieving an annual energy production of 39,214 kWh, a levelized cost of energy (LCOE) of $0.3975/kWh, and a return on investment (ROI) of 62.01% over 20 years, despite a payback period exceeding 30 years. Sensitivity analysis confirms that the system remains moderately resilient under a 10% reduction in solar irradiance or a 20% increase in EV demand. The study also compares the standalone PV configuration, which, while suitable for off-grid applications, results in significant energy underutilization. Moreover, the PV-grid model supports surplus electricity sales, enhancing financial viability. These findings provide actionable insights for stakeholders, energy planners, and policymakers aiming to scale EV charging infrastructure sustainably in Indonesia’s urban environments.

1 December 2025 in International Journal of Applied Power Engineering (IJAPE)
Verified
Journal Article
Open access
PDF file
DPDony Perdana
Dony Perdana
MRMuhamad Nur Rohman
Muhamad Nur Rohman
MCMochamad Choifin
Mochamad Choifin
Vegetable oils have composed of triglycerides, which one consist of 3 fatty acids combined with glycerol. Each saturated and unsaturated fatty acid has a different effect on burning characteristics. This study aimed to investigated effect of fatty acids at ceiba pentandra and jatropha oils on the flame behavior of the droplet combustion process. The combustion characteristic was observed by an ignited droplet at the junction using a thermocouple and a high-speed camera (120 fps). Results showed that a higher saturated fatty acid content resulted in long-life and steady flames. This is because more oleic and linoleic acid carbon atoms leave the droplet area and react with air. Jatropha oil produces a higher temperature of 780 °C than ceiba pentandra oil. Temperature of a vegetable oils flame is influenced by number of carbon chains, double bond, and heating value. Ceiba pentandra oil has a higher burning rate of 0.185 mm/s than jatropha oil at 0.155 mm/s. The chain content of polyunsaturated fatty acids has significant effect on rate of combustion, which is due to the weak van der Waals dispersion forces, such that heat absorption is more active and energetic. The highest flame height for ceiba pentandra oil is 55.03 mm compared to for jatropha oil it is 46.82 mm. Long-chain unsaturated double bonds and glycerol cause micro-explosions. This micro-explosion caused the shape of the flame to split and expand so that evaporation occurred faster, thus increasing the size of the flame.