1 January 2014 in Imaging Science in Dentistry
This study was performed to evaluate the effect of changing the orientation of a reconstructed image on the accuracy of linear measurements using cone-beam computed tomography (CBCT). Forty-two titanium pins were inserted in seven dry sheep mandibles. The length of these pins was measured using a digital caliper with readability of 0.01 mm. Mandibles were radiographed using a CBCT device. When the CBCT images were reconstructed, the orientation of slices was adjusted to parallel (i.e., 0°), +10°, +12°, -12°, and -10° with respect to the occlusal plane. The length of the pins was measured by three radiologists, and the accuracy of these measurements was reported using descriptive statistics and one-way analysis of variance (ANOVA); p<0.05 was considered statistically significant. The differences in radiographic measurements ranged from -0.64 to +0.06 at the orientation of -12°, -0.66 to -0.11 at -10°, -0.51 to +0.19 at 0°, -0.64 to +0.08 at +10°, and -0.64 to +0.1 at +12°. The mean absolute values of the errors were greater at negative orientations than at the parallel position or at positive orientations. The observers underestimated most of the variables by 0.5-0.1 mm (83.6%). In the second set of observations, the reproducibility at all orientations was greater than 0.9. Changing the slice orientation in the range of -12° to +12° reduced the accuracy of linear measurements obtained using CBCT. However, the error value was smaller than 0.5 mm and was, therefore, clinically acceptable.
17 August 2016 in Journal of Dental Research, Dental Clinics, Dental Prospects
Wear Resistance of New Flowable Composites used as Fissure sealant Materials
3 February 2016 in Avicenna Journal of Dental Research
ABAlireza Akbarzadeh Baghban
Alireza Akbarzadeh Baghban
Background: Bidimensional radiographic methods, including periapical, occlusal, panoramic, and cephalometric radiographs, are widely used in dentistry. However, the superimposition of adjacent structures and consequent loss of anatomic details may occur. Objectives: The purpose of this study is to evaluate the artifacts produced by different cements with different densities using cone-beam computed tomography (CBCT). Materials and Methods: Samples of five cements with different densities including glass ionomers (or GI, from ChemFil Rock and Fuji IX), mineral trioxide aggregates (MTA), zinc oxide eugenol (ZOE), TempBond and a control sample (polyester) were scanned by CBCT device and analyzed using OnDemand 3D application software. The amount of artifacts was measured by ∆ gray scale value (∆GSV), which was achieved by subtracting the gray level of the samples from the control group. Results: According to the mean GSV of the five different materials, the majority of artifacts produced were as follows: TempBond > ZOE > MTA > GI (ChemFil Dentsply) > GI (GC, Fuji ΙX). Conclusions: The type of materials can influence the obtained GSV. Different materials cause various amounts of artifacts due to differences in density and atomic number. Keywords: Artifacts; Cone-Beam Computed Tomography; Dental Cements
1 June 2016 in Scholars Journal of Dental Sciences