Sima Nikneshan

Sima Nikneshan

Auto-generated profile, based on publicly available information

Sima Nikneshan

Department of Oral and Maxillofacial Radiology, Dental Faculty, Shahid Beheshti University of Medical Sciences, Tehran, Iran

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Imaging Science in Dentistry
Verified
Journal Article
Open access
PDF file
SNSima Nikneshan
Sima Nikneshan
MSMohamad Sharafi
Mohamad Sharafi
NENaghmeh Emadi
Naghmeh Emadi
Nikneshan S, et al. Imaging Sci Dent. 2013 Sep;43(3):191-196. https://doi.org/10.5624/isd.2013.43.3.191

5 July 2016 in Iranian Journal of Radiology
Verified
Journal Article
Open access
PDF file
SNSima Nikneshan
Sima Nikneshan
SVSolmaz Valizadeh
Solmaz Valizadeh
AJAnahita Javanmard
Anahita Javanmard
LALeila Alibakhshi
Leila Alibakhshi
Background: Selecting a voxel size that yields minimal radiation dose with no significant compromise of the diagnostic accuracy of cone beam computed tomography (CBCT) is particularly important. Objectives: This study aimed to assess the effect of voxel size on detection accuracy of simulated external root resorption defects using NewTom CBCT system. Materials and Methods: In this diagnostic study, the roots of 90 extracted human central incisors were hypothetically divided into cervical, middle, and apical thirds. Variable-size defects were prepared in the buccal and lingual surfaces of the roots and CBCT scans were obtained with four different voxel sizes (150, 200, 250, and 300). Presence or absence of defects on CBCT scans was determined by three radiologists and the results were compared with the gold standard (actual size and depth of defects). Sensitivity and specificity values were calculated and reported for different groups. Results: In the lingual surfaces, the highest specificity and sensitivity belonged to 300µm voxel size (92.9%), and 200 and 250µm voxel sizes (both 97.4%) in the cervical third, respectively. In the middle third, the highest specificity and sensitivity belonged to 250 and 200µm voxel sizes (84.6% and 100%, respectively). In the apical third, the highest specificity and sensitivity belonged to 300 µm voxel size (100% and 97.9%, respectively). In the buccal surfaces, the highest specificity and sensitivity belonged to 150 (75.0%), 300 and 250 µm voxel sizes (100%) and the minimum values belonged to 200 µm voxel size (60% and 97.3%) in the cervical third. In the apical third, the highest specificity and sensitivity were noted in 300 µm voxel size (100% and 97.6%, respectively) and the minimum values were seen in 200 and 150 µm voxel sizes (93.8%, 90.5%, respectively). In the middle third, 300, 250 and 200 µm voxel sizes yielded the highest specificity (88.9%), while 150 µm voxel size yielded the highest sensitivity (98.8%). Conclusion: Considering the similar diagnostic efficacy of all voxel sizes, 300 µm voxel size can be used with adequate efficacy for detection of external root resorption defects with minimal patient radiation dose and the shortest scanning time. Keywords: Accuracy; Cone-Beam Computed Tomography; Root Resorption

1 January 2014 in Imaging Science in Dentistry
Verified
Journal Article
Open access
SNSima Nikneshan
Sima Nikneshan
SAShadi Hamidi Aval
Shadi Hamidi Aval
NBNeema Bakhshalian
Neema Bakhshalian
SSShahriyar Shahab
Shahriyar Shahab
MMMahdis Mohammadpour
Mahdis Mohammadpour
SSSoodeh Sarikhani
Soodeh Sarikhani
This study was performed to evaluate the effect of changing the orientation of a reconstructed image on the accuracy of linear measurements using cone-beam computed tomography (CBCT). Forty-two titanium pins were inserted in seven dry sheep mandibles. The length of these pins was measured using a digital caliper with readability of 0.01 mm. Mandibles were radiographed using a CBCT device. When the CBCT images were reconstructed, the orientation of slices was adjusted to parallel (i.e., 0°), +10°, +12°, -12°, and -10° with respect to the occlusal plane. The length of the pins was measured by three radiologists, and the accuracy of these measurements was reported using descriptive statistics and one-way analysis of variance (ANOVA); p<0.05 was considered statistically significant. The differences in radiographic measurements ranged from -0.64 to +0.06 at the orientation of -12°, -0.66 to -0.11 at -10°, -0.51 to +0.19 at 0°, -0.64 to +0.08 at +10°, and -0.64 to +0.1 at +12°. The mean absolute values of the errors were greater at negative orientations than at the parallel position or at positive orientations. The observers underestimated most of the variables by 0.5-0.1 mm (83.6%). In the second set of observations, the reproducibility at all orientations was greater than 0.9. Changing the slice orientation in the range of -12° to +12° reduced the accuracy of linear measurements obtained using CBCT. However, the error value was smaller than 0.5 mm and was, therefore, clinically acceptable.

1 January 2015 in Journal of Clinical and Experimental Dentistry
Verified
Journal Article
Open access
SASaeed Asgary
Saeed Asgary
SNS Nikneshan
S Nikneshan
AAA Akbarzadeh-Bagheban
A Akbarzadeh-Bagheban
NEN Emadi
N Emadi
This study aimed to assess the diagnostic accuracy of cone beam computed tomography (CBCT) and quantitatively evaluate the morphology of mandibular first molars using CBCT. Twenty-four double-rooted mandibular first molars were evaluated by NewTom VGi CBCT. The distance from the furcation and apex to the cementoenamel junction (CEJ), diameter and thickness of canal walls, the buccolingual (BL) to mesiodistal (MD) ratio (ΔD), prevalence of oval canals at different sections and taper of the canals were all determined. In order to assess the diagnostic accuracy of CBCT, distance from the furcation and apex to the CEJ and thickness of canal walls at the CEJ and apex were compared with the gold standard values (caliper and stereomicroscope). Statistical analyses were carried out using intraclass correlation coefficient (ICC), paired t-test and repeated measures ANOVA. A high correlation existed between the CBCT and gold standard measurements (P<0.001). In dimensional measurements, length of mesial root was higher than the distal root and lingual furcation was farther from the CEJ than the buccal furcation (P<0.001). An important finding of this study was the mesiodistal taper of the mesiobuccal (MB) and mesiolingual (ML) canals; which was equal to 0.02. CBCT has acceptable diagnostic accuracy for measurement of canal wall thickness. Cleaning and shaping of the canals should be performed based on the unique anatomy of the respective canal; which necessitates the use of advanced imaging techniques for thorough assessment of root canal anatomy in a clinical setting. Permanent mandibular first molar, accuracy, cone-beam computed tomography, dimensional measurement.

22 April 2014 in Iranian Journal of Radiology
Verified
Journal Article
Open access
PDF file
SNSima Nikneshan
Sima Nikneshan
SMSudeh Mohseni
Sudeh Mohseni
MNMahtab Nouri
Mahtab Nouri
HHHoora Hadian
Hoora Hadian
MKMohammad Javad Kharazifard
Mohammad Javad Kharazifard
Background: Evaluation of the craniofacial bones is the oldest method to measure the facial proportion ratio in orthodontics. Objectives: The purpose of this study was to evaluate the effect of emboss enhancement on the reliability of landmark identification in digital lateral cephalometric images. Materials and Methods: Ten digital lateral cephalograms were selected from the archive of an oral and maxillofacial radiology center. Using DIGORA software, these images were saved in two formats; common images and 3D emboss images. On these images, 32 skeletal, dental, and soft tissue landmarks were marked at least twice with a 2-week interval by four observers (two radiologists and two orthodontists). In order to determine the position of the marked landmarks (in x and y coordinates), a software was designed. The statistical analysis was performed in SPSS software and the reliability of each observer was obtained by means of intraclass correlation coefficient (ICC). Results: In three skeletal landmarks [Orbit (Or), condyl top (Cond), and pogonion (Pog)], the enhancement caused significant reduction in the reliability, and in four skeletal [Anterior Nasal Spine (ANS), B, A, and Basion (Ba)], two dental (U1 root, L1 incisal), and one soft tissue landmark (Menton soft tissue), the enhancement increased the reliability of landmark detection between the two phases of the study. Totally, ICC of embossed images in both x and y coordinates were greater than the typical images, but the difference was not statistically significant. However, the effect of enhancement on the improvement of the reliability of landmark identification was higher in the x-axis than the y-axis. Conclusions: Using embossed images is only effective in increasing the reliability of detection in a few numbers of cephalometric landmarks. Keywords: Cephalometry; Emboss Enhancement; Reliability

1 January 2015 in Indian Journal of Dental Research
Verified
Journal Article
Open access
SSSedigheh Sabbagh
Sedigheh Sabbagh
SNSima Nikneshan
Sima Nikneshan
FAFatemehMashhadi Abbas
FatemehMashhadi Abbas
Dental radiography is an important tool for detection of caries and digital radiography is the latest advancement in this regard. Spatial resolution is a characteristic of digital receptors used for describing the quality of images. This study was aimed to compare the diagnostic accuracy of two digital radiographic systems with three different resolutions for detection of noncavitated proximal caries. Diagnostic accuracy. Seventy premolar teeth were mounted in 14 gypsum blocks. Digora; Optime and RVG Access were used for obtaining digital radiographs. Six observers evaluated the proximal surfaces in radiographs for each resolution in order to determine the depth of caries based on a 4-point scale. The teeth were then histologically sectioned, and the results of histologic analysis were considered as the gold standard. Data were entered using SPSS version 18 software and the Kruskal-Wallis test was used for data analysis. P 0.05). RVG access system had the highest specificity (87.7%) and Digora; Optime at high resolution had the lowest specificity (84.2%). Furthermore, Digora; Optime had higher sensitivity for detection of caries exceeding outer half of enamel. Judgment of oral radiologists for detection of the depth of caries had higher reliability than that of restorative dentistry specialists. The three resolutions of Digora; Optime and RVG access had similar accuracy in detection of noncavitated proximal caries.