Eric Cattan

Eric Cattan

Auto-generated profile, based on publicly available information

Eric Cattan

Univ. Polytechnique Hauts-de-France, CNRS, Univ. Lille, UMR 8520 - IEMN, F-59313 Valenciennes, France

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2020 in Journal of Fluids and Structures
Verified
Journal Article
Closed access
MCMathieu Colin
Mathieu Colin
OTOlivier Thomas
Olivier Thomas
SGSébastien Grondel
Sébastien Grondel
ÉCÉric Cattan
Éric Cattan

9 September 2002 in Applied Physics Letters
Verified
Journal Article
Closed access
PDF file
JDJ. R. Duclère
J. R. Duclère
MGM. Guilloux-Viry
M. Guilloux-Viry
APA. Perrin
A. Perrin
ECE. Cattan
E. Cattan
CSC. Soyer
C. Soyer
DRD. Rèmiens
D. Rèmiens
Epitaxial SrBi2Nb2O9 thin films have been grown by pulsed-laser deposition on (110)Pt bottom electrode epitaxially grown on (110) SrTiO3 by dc sputtering. X-ray φ-scans and electron channeling patterns reveal the epitaxial growth of the (116) SrBi2Nb2O9/(110)Pt bilayers. The hysteresis loop, dielectric response, and capacitance–voltage characteristics of this bilayer are presented. The remnant polarization was measured to be close to 5 μC/cm2, and the coercive field was calculated to be ∼120 kV/cm. The zero field permittivity was about 150 and the dielectric loss was ∼2%.

16 February 2021 in IEEE Access
Verified
Journal Article
Open access
CPChia-Ju Peng
Chia-Ju Peng
LSLaureline Seurre
Laureline Seurre
ECEric Cattan
Eric Cattan
GNGiao Tran-Minh Nguyen
Giao Tran-Minh Nguyen
CPCédric Plesse
Cédric Plesse
BCBarthelemy Cagneau
Barthelemy Cagneau
Grasping and manipulating objects on a microscale hold great promise, especially using mechanical structures made from soft materials that enable, for example, safe operations during microsurgery. Soft robots should be preferred to manipulate micro-objects, but their adoption requires, inter alia, soft transducers that can operate either in air or in solution. Ultimately, they should enable actuation at low voltage, as well as be easy to fabricate. This paper presents the results on our investigations about conducting polymers -based transducers. We demonstrate that this material is suitable to construct sensitive structures and a microgripper is proposed to illustrate the results. Large strains were observed and a grasping force of 0.17 mN was generated. Moreover, compared to previous work, we show that the fabrication process can be downscaled while preserving the behavior of the material in both actuation and sensing modes. The macroscale mechanical models obtained are still valid for microscale actuation and sensing.

24 May 2005 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
MGM. Guilloux-Viry
M. Guilloux-Viry
JDJ. R. Duclère
J. R. Duclère
ARA. Rousseau
A. Rousseau
APA. Perrin
A. Perrin
DFD. Fasquelle
D. Fasquelle
DRD. Rèmiens
D. Rèmiens
Ferroelectric and dielectric characteristics of two types of SrBi2Nb2O9 thin films grown by pulsed laser deposition on Pt electrodes were determined: a randomly oriented SrBi2Nb2O9 film (sample A), grown on a so-called polycrystalline Pt∕Ti∕SiO2∕Si (Pt∕Si) and an epitaxial SrBi2Nb2O9 film (sample B) grown on a (110)Pt electrode epitaxially grown on (110)SrTiO3 . Some h00 texturation was suggested by the strong intensity of the 200 diffraction peak in sample A whereas the epitaxial sample B presents a strongly (116) preferential orientation as evidenced by x-ray diffraction and electron channeling patterns. Remanent polarization (Pr) determined from the hysteresis loops recorded on several electrodes on samples A and B was typically in the range of 5–8.5μC∕cm2 for both samples. The Curie temperature (TC) determined from dielectric permittivity measurements versus temperature was 705K , for both samples, which differ, in fact, in structural characteristics but not in composition. The Curie–Weiss temperature was found lower than TC , suggesting that the transition is of first order. The evolution of dielectric permittivity and dissipation factor was recorded versus frequency at different temperatures. At room temperature and low frequency (100Hz) , ε′ is close to 150 on both films. When increasing the frequency up to 1MHz , the ε′ value decreased down to 137 for sample A and 129 for sample B. This evolution corresponds to a weak dispersion effect in relation with the high crystallization quality of the ferroelectric films. At the same time, dissipation factor tgδ increased from 1.5% to 1.8% and from 3.3% to 5.5% for samples A and B, respectively, when increasing the frequency from 100Hzto1MHz . Further measurements at higher frequency were performed on the epitaxial film. As expected, dielectric permittivity decreased to about 100 when increasing the frequency to 0.5GHz at room temperature, whereas tgδ increased up to about 9%. Decreasing the temperature down to 110K contributes to decrease ε′ from 150 at room temperature to 122 at 110K at 1kHz and from 100 to 87 at 0.5GHz . Simultaneously, tgδ decreases from 8.7% to 5.6% at 0.5GHz .

1 March 1999 in Ferroelectrics
Verified
Journal Article
Closed access
David JenkinsDavid Jenkins
David Jenkins
WCW. W. Clegg
W. W. Clegg
GVGabriel Velu
Gabriel Velu
ECE. Cattan
E. Cattan
DRD. Remiens
D. Remiens
In order to utilise PZT thin films for MEMS applications it is essential to optimise the d 31 coefficient in order to maximise actuation efficiency. The d 31 coefficient, which can be optimised by the poling process, should be different for films of different orientation. PZT thin films of , and have been deposited onto platinised silicon, their d 31 coefficient measured and their effectiveness as microactuators compared and evaluated.

23 July 2020 in Smart Materials and Structures
Verified
Journal Article
Closed access
KRKätlin Rohtlaid
Kätlin Rohtlaid
LSLauréline Seurre
Lauréline Seurre
GNGiao T M Nguyen
Giao T M Nguyen
GCGarrett Curley
Garrett Curley
CSCaroline Soyer
Caroline Soyer
ECEric Cattan
Eric Cattan
The demand for polymer-based soft micro-electro-mechanical systems (MEMS) is growing due to the substantial increase of flexible and wearable electronic devices. In this context, electronically conducting polymers (ECPs) fulfil the requirements for soft MEMS by offering the possibility of actuation and sensing, however, their miniaturization, their integration attempts and their resulting performances are still limiting their use in real applications. In this work, elaboration, integration and operation of soft and efficient microtransducers based on commercially available poly(3,4-ethyledioxythiophene):poly(styrene sulfonate) conductive ink into flexible chips is demonstrated. This original process overcomes existing hurdles to the fabrication of fully integrated ECP-based devices with gold remote contacts directly in contact with ECPs and further embedding in flexible support. These batch-fabricated chips are actuated at low voltage (±3.0 V) in open-air with individual accessible electrical connections. More importantly, the mechanical strain sensing is evidenced for the first time on such small ECP-based devices after full integration and demonstrating low impact of the microfabrication process. This work opens the way for further development of soft ECP-MEMS and integration into more complex systems with possible applications in microrobotics, microfluidics, optoelectronics, biology, medicine or space.