Jaehyuk Lee

Jaehyuk Lee

Auto-generated profile, based on publicly available information

Jaehyuk Lee

System Research Center, Samsung Advanced Institute of Technology, Suwon, South Korea

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 March 2018 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
UHUnsoo Ha
Unsoo Ha
JLJaehyuk Lee
Jaehyuk Lee
MKMinseo Kim
Minseo Kim
TRTaehwan Roh
Taehwan Roh
SCSangsik Choi
Sangsik Choi
HYHoi-Jun Yoo
Hoi-Jun Yoo
In surgical operation environments, anesthesia enables doctors to safe and accurate medical process with minimized movement and pain of patients. In general anesthesia, non-invasive and reliable monitoring of anesthesia depth is required because it is directly related to patient's life. However, the current anesthesia depth monitoring approach, bispectral index (BIS), uses only electroencephalography (EEG) from the frontal lobe, and it shows critical limitations in the monitoring of anesthesia depth such as signal distortion due to electrocautery, electromyography (EMG) and dried gel, and false response to the special types of anesthetic drugs. In this paper, a multimodal head-patch system that simultaneously measures EEG and near-infrared spectroscopy (NIRS) on the frontal lobe is proposed. For EEG monitoring, mixed-mode dc-servo loop is proposed to cancel out the ±300-mV electrode-dc offset for dried gel condition with 3.59 noise-efficiency factor. To compensate the electromagnetic noises (EMG and electrocautery) in the system level, NIRS signal is measured. Logarithmic transimpedance amplifier (TIA) and closed-loop controlled (CLC) NIRS current driver are proposed. Logarithmic TIA can reject ambient light up to 10 nA to achieve a 60-dB dynamic range. According to the comparator output, CLC NIRS driver duty cycle can be adjusted from 0.625 m to 50 ms adaptively. The 16-mm² system-on-chip is fabricated in 65-nm CMOS. It dissipates 25.2-mW peak power. With the combined signals, it can show the clinically important transition from the awake to deep state, but BIS cannot detect the transition in a clinical trial.

9 January 2019 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
JLJaehyuk Lee
Jaehyuk Lee
KLKyoung-Rog Lee
Kyoung-Rog Lee
UHUnsoo Ha
Unsoo Ha
JKJi-Hoon Kim
Ji-Hoon Kim
KLKwonjoon Lee
Kwonjoon Lee
HYHoi-Jun Yoo
Hoi-Jun Yoo

6 November 2020 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
JLJaehyuk Lee
Jaehyuk Lee
SGSurin Gweon
Surin Gweon
KLKwonjoon Lee
Kwonjoon Lee
SUSoyeon Um
Soyeon Um
KLKyoung-Rog Lee
Kyoung-Rog Lee
HYHoi-Jun Yoo
Hoi-Jun Yoo
An eight-channel 10-MHz wide-bandwidth electrical impedance tomography (EIT) IC is proposed for early breast cancer detection system. To increase the resolution of EIT images, the proposed IC has three key features: 1) wide-bandwidth instrumentation amplifier (WB-IA) to detect large impedance changes in cancer cells at a high frequency; 2) dual-mode driver (DM-driver) to obviate the complex switching network to reduce the noise and the system form factor; and 3) phase compensation loop (PCL) to efficiently correct the phase error for accurate images without artifacts. The proposed EIT IC occupies 16 mm 2 in the 65-nm CMOS technology and consumes 9.6 mW for each channel. Thanks to the key features, the proposed breast cancer detection system with the dedicated EIT IC can operate up to 10 MHz with a small phase error of 4.32° and a state-of-the-art impedance resolution of 1.6 mQ/√Hz eventually can detect a small-size target object of 0.5 cm and verify with the phantom experiments.

29 July 2020 in IEEE Journal of Solid-State Circuits
Verified
Journal Article
Closed access
JJJaeeun Jang
Jaeeun Jang
JLJihee Lee
Jihee Lee
HCHyunwoo Cho
Hyunwoo Cho
JLJaehyuk Lee
Jaehyuk Lee
HYHoi-Jun Yoo
Hoi-Jun Yoo
In this article, a body channel communication (BCC) transceiver (TRX) and low-power receiver (RX) that can cover wide applications are proposed. The IEEE 802.15.6 human body communication (HBC) physical layer (PHY) standard and high-speed data transmission are supported simultaneously with a single chip. First, the sinusoidal-modulated transmitter is proposed for the standard mode TRX, and it can reduce filtering power overhead 35%. Second, high-speed TRX is proposed that can support dual-band QPSK modulation to increase system data rate and bandwidth efficiency. Third, on-chip RC duplexer is proposed for full-duplex function in communication. Also, for the low-power RX, a wireless power transfer (WPT)-based wake-up receiver (WuRX) and a higher energy efficiency main RX is integrated into RX chip. The main HBC RX demodulates both ASK and frequency-shift keying (FSK) information with a sharing oscillator (OSC) with 31-μW low-power consumption. The TRX and RX are implemented in 65-nm CMOS process.

3 January 2023 in Applied Acoustics
Verified
Journal Article
Closed access
JLJaehyuk Lee
Jaehyuk Lee
JKJaehyung Kim
Jaehyung Kim
YSYujin Shin
Yujin Shin
JJJuhyun Jeon
Juhyun Jeon
YKYeon June Kang
Yeon June Kang
IJInhwa Jung
Inhwa Jung

6 March 2017
Verified
Conference Paper
Closed access
MKMinseo Kim
Minseo Kim
HKHyunki Kim
Hyunki Kim
JJJaeeun Jang
Jaeeun Jang
JLJihee Lee
Jihee Lee
JLJaehyuk Lee
Jaehyuk Lee
HYHoi-Jun Yoo
Hoi-Jun Yoo
Electrical impedance tomography (EIT) has been studied to monitor lung ventilation because it is the only real-time lung imaging method without large equipment [1–2]. However, previous EIT systems just provided 2D cross-sectional image with limited spatial information of the lung and unneglectable volume detection error depending on the location of 2D EIT belt relative to the patient's lung. In spite of its importance, the 3D-EIT has not been realized in lung monitoring because it has many design challenges such as noises incurred by complicated wiring, long cable length, wide variation in electrode contact and signal, and large personal-to-person impedance variation. In this paper, we present a portable 3D-EIT SoC for real-time lung ventilation monitoring with following 5 features: 1) The active electrodes (AEs) system to reduce coupling noise, 2) High output impedance current stimulator to inject stable current, 3) Impedance spectroscopy to enable both time-difference (TD) EIT and frequency-difference (FD) EIT, and to select an optimal frequency for TD-EIT, 4) Wide-dynamic range front-end circuit to detect variable ranges of signal with high-input impedance and CMRR, 5) Calibration to reduce the electrical characteristics variations of AEs.