4 May 2017 in IEEE Journal of Solid-State Circuits
An ultra-low power true random number generator (TRNG) based on a sub-ranging SAR analog-to-digital converter (ADC) is proposed. The proposed TRNG is composed of a coarse-SAR ADC with a low-power adaptive-reset comparator and a low-power dynamic amplifier. The coarse-ADC part is shared with a sub-ranging SAR ADC for area reduction. The shared coarse-ADC not only plays the role of discrete-time chaotic circuit but also reduces the overall SAR ADC energy consumption by selectively activating the fine-SAR ADC. Also, the proposed dynamic residue amplifier consumes only 48 nW and the adaptive-reset comparator generates a chaotic map with only 6-nW consumption. The proposed TRNG core occupies 0.0045 mm2 in 0.18-μm CMOS technology and consumes 82 nW at 270-kbps throughput with 0.6-V supply. It successfully passes all of National Institute of Standards and Technology (NIST) tests, and it achieves the state-of-the-art figure-of-merit of 0.3 pJ/bit.
20 March 2018 in IEEE Journal of Solid-State Circuits
In surgical operation environments, anesthesia enables doctors to safe and accurate medical process with minimized movement and pain of patients. In general anesthesia, non-invasive and reliable monitoring of anesthesia depth is required because it is directly related to patient's life. However, the current anesthesia depth monitoring approach, bispectral index (BIS), uses only electroencephalography (EEG) from the frontal lobe, and it shows critical limitations in the monitoring of anesthesia depth such as signal distortion due to electrocautery, electromyography (EMG) and dried gel, and false response to the special types of anesthetic drugs. In this paper, a multimodal head-patch system that simultaneously measures EEG and near-infrared spectroscopy (NIRS) on the frontal lobe is proposed. For EEG monitoring, mixed-mode dc-servo loop is proposed to cancel out the ±300-mV electrode-dc offset for dried gel condition with 3.59 noise-efficiency factor. To compensate the electromagnetic noises (EMG and electrocautery) in the system level, NIRS signal is measured. Logarithmic transimpedance amplifier (TIA) and closed-loop controlled (CLC) NIRS current driver are proposed. Logarithmic TIA can reject ambient light up to 10 nA to achieve a 60-dB dynamic range. According to the comparator output, CLC NIRS driver duty cycle can be adjusted from 0.625 m to 50 ms adaptively. The 16-mm² system-on-chip is fabricated in 65-nm CMOS. It dissipates 25.2-mW peak power. With the combined signals, it can show the clinically important transition from the awake to deep state, but BIS cannot detect the transition in a clinical trial.
23 October 2018 in IEEE Journal of Solid-State Circuits
A small form-factor, lightweight wireless capsule endoscope (WCE) system with body channel communication (BCC) transceiver ICs is proposed for VGA-resolution image transferring and capsule localization. The transceiver ICs are composed of capsule chip and receiver chip, implemented in a 65-nm CMOS process. In the capsule side, the proposed system provides 360° image capturing through four-camera integration to reduce the miss rate. Also, a dual-band pulse-shaping BCC transmitter is proposed to enable low-power (<1 mW), high-speed (80 Mb/s) image transmission. In the receiver side, contact attenuation compensated-received signal strength indicator (CAC-RSSI) is proposed to increase the capsule localization accuracy. The external system is composed of eight-receiver nodes that allow signal demodulation and localization of the capsule. To reduce transceiver payload and system power consumption, image encoder is implemented in the capsule. The transceiver IC is integrated into the capsule system and verified with body mimicking phantom. The proposed system satisfies compatibility with medical grade diagnosis by operating longer than 8 h with 4 fps and 12 h with 2 fps with conventional two silver oxide 55-mA· h coin batteries. The tested localization accuracy shows less than sub-centimeter range.
3 October 2017 in IEEE Journal of Solid-State Circuits
A wearable electrical impedance tomography (EIT) system is proposed for the portable real-time 3-D lung ventilation monitoring. It consists of two types of SoCs, active electrode (AE)-SoC and Hub-SoC, mounted on wearable belts. The 48-channel AE-SoCs are integrated on flexible printed circuit board belt, and Hub-SoC is integrated in the hub module which performs data gathering and wireless communication between an external imaging device. To get high accuracy under the variation of conductivity, the dual-mode current stimulator provides the optimal frequency for time difference-EIT and frequency difference-EIT with simultaneous 4 k-128 kHz impedance sensing. A wide dynamic range instruments amplifier is proposed to provide 94 dB of wide dynamic range impedance sensing. In addition, the 48-channel AE system with the dedicated communication and calibration is implemented to achieve 1.4-mΩ sensitivity of impedance difference in the in vivo environment. The AE-/Hub-SoCs occupy 3.2 and 1.3 mm²in 65-nm CMOS technology and consume 124 μW and 1.1 mW with 1.2 V supply, respectively. As a result, EIT images are reconstructed with 90% of accuracy, and up to 10 frames/s real-time 3-D lung images are successfully displayed.
1 August 2020 in IEEE Journal of Solid-State Circuits
Continuous monitoring of fluid status through bio-impedance (Bio-Z) measurement of thoracic magnitude or phase is critical in reducing the mortality of chronic heart failure (CHF) patients. However, the stringent power constraints of implantable devices force the design of Bio-Z sensors to be highly challenging. We present a sub-10-μW Bio-Z sensor IC operating from a 0.5 V-supply, sustaining a sub-1° of phase error even under 10% of supply and 0 °C-70 °C of temperature variations. Fabricated in a 65-nm CMOS process, this sensor IC exhibits a 15.28-mΩ/√Hz of input-referred impedance noise performance, occupying a 4.83 mm². Its linearity performance shows that the magnitude and the phase of Bio-Z can be measured within the error of 2% and 0.4°, respectively, given that the magnitude of load impedance is less than 126 Ω, and thus, it is suitable for fluid status monitoring applications. Experimental measurement on the human chest demonstrates its capabilities of thoracic impedance variance (TIV) and impedance cardiography (ICG) monitoring.
24 October 2024 in IEEE Transactions on Circuits and Systems I: Regular Papers
Artificial neural networks have led to a higher computational burden, complicating inference tasks on low-power edge devices. Spiking neural network (SNN), which leverages sparse spikes for computation and data transmission, is an effective energy-efficient computing technique. However, the length of spike sequences in SNN varies significantly depending on the input coding method, among which rate coding still results in substantial data movement. A highly energy-efficient SNN accelerator with a time-domain CIM processor is proposed with three key features: 1) time-domain bitcell array for high linearity with lower energy, reducing 58.6% power consumption compared to inverter-chain architecture, 2) time-domain multi-bit accumulate for assisting multi-bit weights without analog-to-digital converter, achieving 47.2% energy reduction of domain-conversion energy, 3) analog precision reconstruction unit for supporting phase coding. The proposed TS-CIM is designed in 65 nm CMOS technology and achieves 701.7 TOPS/W energy efficiency, marking a 1.58 $\times$ enhancement compared to the state-of-the-art SNN CIM.