Shengjie Qi

Shengjie Qi

Auto-generated profile, based on publicly available information

Shengjie Qi

School of Instrumentation and Optoelectronic Engineering, Beihang University, Beijing, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 January 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
LJLe Jia
Le Jia
JLJianli Li
Jianli Li
Xinda SongXinda Song
Xinda Song
SQShengji Qi
Shengji Qi
TLTengyue Long
Tengyue Long
XNXiaolin Ning
Xiaolin Ning
Aiming at the issue of substantial nonlinear error arising from triaxial DC magnetic field interferences in wearable and mobile measurement scenarios, a triaxial magnetic fields response model of single-beam atomic SERF magnetometer under non-zero magnetic condition is established, revealing that the effect of triaxial DC magnetic field interferences on the detected AC responses exhibits the nonlinear feature, while their impact on the DC response manifests as the interval-linear characteristic. Consequently, a closed-loop control system for mixed AC and DC magnetic fields is proposed. By leveraging the DC response within the feedback signal, a localized linearization control strategy is implemented across the triaxial magnetic fields, enabling direct and real-time suppression of DC interferences, and subsequently reducing their nonlinear impact on the measured AC response. Among them, the nonlinear impact caused by x-axis DC magnetic field interference decreases from 48.12% in the open-loop configuration to 0.01%. Additionally, it takes less time to suppress the interferences to below 2%, shortened from 4.7 s to 32 ms.

7 April 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JZJing Zhang
Jing Zhang
Xinda SongXinda Song
Xinda Song
LJLe Jia
Le Jia
HSHaoyuan Sun
Haoyuan Sun
SQShengjie Qi
Shengjie Qi
GLGang Liu
Gang Liu
Wearable optically pumped magnetometers (OPMs) operating in the spin-exchange relaxation-free (SERF) regime are an emerging alternative for biomagnetic field measurements. Nevertheless, the wearable implementation of OPM inevitably entails positional variations, leading to magnetic field disturbance and the introduction of amplitude errors, consequently impacting the precision of magnetic source localization. To solve this problem, an enhanced method is presented for wearable OPMs, which can achieve real-time suppression of magnetic field disturbance without overshoot. First, we analyze the influence mechanism of magnetic field disturbance on OPMs, thereby clarifying the nonlinear impact that disturbance exerts on the system. Then, a magnetic field disturbance suppression system based on active disturbance rejection control (ADRC) is developed to estimate and compensate for magnetic field disturbance in real time. The experimental results demonstrate that the ADRC method enables overshoot-free fast response and tracking suppression for the sensitive x-axis magnetic field disturbances. Moreover, the settling time is shortened to 3.3 ms compared to the 15.4 ms required by the PI method, which extends the effective duration of the signal under measurement. Furthermore, the amplitude errors in the y-axis and z-axis are reduced by 38.29% and 47.10%, respectively. Finally, the enhanced magnetic field disturbance suppression method proposed in this paper provides valuable technical support for wearable medical applications of OPM.

1 January 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
HSHaoyuan Sun
Haoyuan Sun
JZJing Zhang
Jing Zhang
LJLe Jia
Le Jia
TLTengyue Long
Tengyue Long
SQShengjie Qi
Shengjie Qi
GLGang Liu
Gang Liu