12 July 2021 in IEEE Journal of Emerging and Selected Topics in Power Electronics
As a multiport DC–DC converter, quad-active bridge (QAB) has been widely used in energy routers, photovoltaic energy systems, and vehicle power supplies because of its advantages of high efficiency and high power density. However, every port of the QAB converter is coupled together through a high-frequency (HF) transformer, which poses a challenge to the controller design. This article proposes a sliding mode controller (SMC)-based decoupling control scheme, which combines input matrix diagonalization and extended state observer (ESO). The input matrix diagonalization realizes most coupling and the SMC realizes the remaining coupling. To effectively reduce the chattering caused by the SMC, the ESO is applied to estimate the total disturbances. Theoretical analysis shows that the proposed decoupling control scheme transforms a multiple input multiple output (MIMO) control system into three independent single-input single-output (SISO) control systems, which realizes independent control of all the port voltages. Besides, experimental results show that the proposed scheme can almost eliminate the coupling relationship between ports, and improve the dynamic response of the system.
16 February 2022 in IEEE Transactions on Transportation Electrification
This article proposed a current-sensorless control scheme for the single-phase uninterruptible power supply (UPS) inverter under nonlinear load. Different from the existing current-sensorless literature, the information of load current can be obtained by the designed adaptive laws. It is meaningful for the system’s security and reliability. Under the assumption that the load is a periodic ideal-independent current source, the Fourier series in trigonometric form is expanded to model the unknown disturbance of load current. The observer-based feedback control rate and update laws are derived to adjust online the Fourier coefficients of the load current modeling. Furthermore, the stability of the system is rigorously analyzed via the Lyapunov approach. Under the same limitation of not using the current sensor, comparative experiments are designed. Simulation and experimental results have verified the effectiveness of the control approaches.
25 February 2021 in IEEE Transactions on Industrial Electronics
In this article, a resistance-emulating control strategy without grid voltage sensors is proposed for three-phase voltage source rectifiers under unbalanced grid conditions. It consists of angle estimator, coordinate correction, resistance-emulating, common-mode resistance (CMR) and the differential-mode resistance (DMR) regulation, extended state observer, and other critical steps. In this scheme, the CMR regulates the average power, and the DMR controls the ripple power caused by the unbalanced supplies. Three different control objectives including constant active power, symmetrical input currents, and constant reactive power are achieved by regulating the DMR. Since the grid voltage sensors and the information of the grid-side circuit parameters are not required, the cost is reduced and the robustness and reliability of the scheme is improved. Experiments verify the effectiveness of the proposed method.
1 January 2019 in IEEE Transactions on Power Electronics
This study proposes a generalized design framework for three phase Vienna rectifiers to handle the neutral point voltage balance issue. On the basis of the design framework, it is convenient to construct various neutral point voltage balancing methods with the guarantee of stability. As demonstration, three representative neutral point voltage balance approaches are presented by choosing different zero sequence voltages. A comprehensive comparison among the three approaches are given in the aspects of input current quality, capacitor voltage fluctuation, and system efficiency. The comparison results provide a guidance for constructing the most appropriate approach based on the specific requirement. Finally, simulation and experimental results verify the correctness and effectiveness of the presented approaches and the related performance analysis.
19 April 2021 in IEEE Transactions on Power Electronics
This article proposes an adaptive power decoupling control strategy for a single-phase rectifier with an unbalanced split-capacitor decoupling circuit. Since a capacitance mismatch estimator is integrated into the control strategy, the impact of capacitance mismatch is eliminated. Meanwhile, the capacitance mismatch estimator can provide an auxiliary online monitor for the health of split capacitors. Moreover, the mechanism of capacitor voltages self-balance is explained. Finally, experiments are conducted to verify the effectiveness of the proposed method.
7 October 2020 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Due to the disparity of power modules, asymmetry of driving pulses and measurement errors of sensors, dc currents may be injected to grid-connected photovoltaic (PV) inverters. The dc current injection may cause magnetic saturation of the power transformers. To solve this issue, this paper thus proposes an effective current control strategy and compensation method, which does not require any extra sensor and hardware circuit. Firstly, the root-cause of dc current injection is comprehensively analyzed. Subsequently, a proportional-integral-resonant (PIR) controller is proposed to eliminate the dc component caused by disparity of power modules, asymmetry of driving pulses and measurement errors of grid voltage. The injected dc current caused by grid current measurement error is estimated from the line-frequency ripple of the dc-link voltage and then it is suppressed by a feedback compensation controller. In addition, the dc current rejection capability is evaluated and the proposed method is benchmarked with the virtual capacitor-based method. Finally, experimental tests are performed on a 1.2-kW single-phase PV inverter to verify the effectiveness of the proposal.