Chao Wang

Chao Wang

Auto-generated profile, based on publicly available information

Chao Wang

State Grid Shanxi Economic Research Institute,Planning Review Center,Taiyuan,China

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 January 2020 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
CWChao Wang
Chao Wang
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
Voltage feedback flux-weakening control has the advantages of simplicity and robustness against parameter variation. However, due to less voltage control margin in the flux-weakening region, the increased feedback voltage ripple could deteriorate the system performance in the flux-weakening region and may even cause oscillation. In this paper, based on a non-salient permanent magnet synchronous machine (PMSM), the steady-state feedback voltage ripple in the flux-weakening region are analyzed first. It shows that the feedback voltage ripple caused by the current command ripple could dominate in some flux-weakening regions. Consequently, the speed bandwidth based on the conventional speed proportional-integral (PI) controller in the flux-weakening region can be hardly increased, which leads to poor dynamic performance. In order to obtain both fast speed dynamics and less steady-state ripple, especially in the flux-weakening region, an adaptive fuzzy logic (FLC) speed controller is designed and compared with the conventional speed PI controller. With the adaptive FLC, the DC-link voltage utilization can be increased and better flux-weakening capability can be obtained. Finally, the improved performances are verified by the experimental results.

24 May 2018 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
ZWZ. Z. Wu
Z. Z. Wu
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
CWC. Wang
C. Wang
JMJ. C. Mipo
J. C. Mipo
SPS. Personnaz
S. Personnaz
PFP. Farah
P. Farah
In this paper, the open-circuit dc-winding-induced voltage in a wound field switched flux (WFSFs) machines is analyzed. The phenomenon of open-circuit dc-winding-induced voltage is illustrated and the mechanism is explained. Rotor skewing is proposed to reduce the open-circuit dc-winding-induced voltage, and the optimal skewing angle is analytically derived based on the analytically deduced harmonic orders of the open-circuit dc-winding-induced voltage. Finite-element (FE) analyses show that the open-circuit dc-winding-induced voltages in the analyzed 12-stator-pole partitioned stator WFSF machines having 10-, 11-, 13-, and 14-rotor-pole rotors can be effectively reduced by >94%, while the ac-winding phase-fundamental back-EMFs can be maintained by >95%. Twelve/ten-stator/rotor-pole prototypes with skewed and nonskewed rotors are built and tested to verify the analytical and FE results.

6 December 2019 in IEEE Transactions on Industry Applications
Verified
Journal Article
Closed access
CWChao Wang
Chao Wang
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
HZHanlin Zhan
Hanlin Zhan
This article investigates the nonlinear behavior of the conventional voltage feedback flux-weakening control, i.e., the voltage magnitude feedback control on the nonsalient permanent magnet synchronous machine, and proposes an adaptive control parameter tuning method for the voltage feedback controller. Due to less voltage margin in the flux-weakening region, the current dynamic performance is degraded. This issue is more serious when the system operates in the overmodulation region and could affect the system's stability. Based on the designed voltage feedback controller, the system performance in the flux-weakening and overmodulation regions is further improved by utilizing the current and voltage reference modifiers. Consequently, the system can operate well in both linear and overmodulation regions with the specified scaling factor, which is beneficial to general-purpose applications. The viability of the proposed method is demonstrated by the experimental results.

29 April 2019 in IEEE Transactions on Industrial Electronics
Verified
Journal Article
Closed access
Zhongze WuZhongze Wu
Zhongze Wu
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
CWChao Wang
Chao Wang
JMJean-Claude Mipo
Jean-Claude Mipo
SPSophie Personnaz
Sophie Personnaz
PFPhilippe Farah
Philippe Farah
DC winding induced voltage pulsation in wound field switched flux (WFSF) machines causes DC winding current ripple and field excitation fluctuation, challenges the DC power source and deteriorates the control performance. Hence, reducing this pulsation is important in the design of a WFSF machine. In this paper, based on the analytical models, rotor skewing and rotor iron piece pairing are proposed and comparatively investigated by the finite element (FE) method to reduce the on-load DC winding induced voltage in WFSF machines having partitioned stators and concentrated AC windings. FE results show that peak to peak value of the on-load DC winding induced voltage in the analysed 12/10-pole partitioned stator WFSF (PS-WFSF) machines can be reduced by 78.42% or 77.16% by using rotor skewing or rotor pairing, respectively, whilst the torque density can be maintained by >90%. As for the 12/11-, 12/13- and 12/14-pole PS-WFSF machines, by using rotor iron piece inner arc pairing, the on-load DC winding induced voltage can be reduced by 64.11%, 52.12% and 76.49%, respectively, whilst the torque density can also be maintained by more than 90%. Prototypes are built and tested to verify the analytical and FE results.

1 September 2020 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
SCShun Cai
Shun Cai
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
CWC. Wang
C. Wang
JMJean-Claude Mipo
Jean-Claude Mipo
SPSophie Personnaz
Sophie Personnaz

12 June 2018 in IEEE Transactions on Energy Conversion
Verified
Journal Article
Closed access
ZWZ. Z. Wu
Z. Z. Wu
Z. Q. ZhuZ. Q. Zhu
Z. Q. Zhu
CWC. Wang
C. Wang
JMJean-Claude Mipo
Jean-Claude Mipo
SPSophie Personnaz
Sophie Personnaz
PFPhillipe Farah
Phillipe Farah
DC winding induced voltage pulsation in the wound field synchronous machines (WFSMs) will cause DC winding current ripple, challenge the DC power supply and deteriorate the control performance, especially at a high speed. In this paper, the influence of DC winding configuration including the DC coil number and the parallel branch number on its induced voltage pulsation is investigated for WFSMs. Based on the modelling of both open-circuit and on-load DC winding induced voltages, the preferred DC winding configurations for WFSMs having various stator / rotor pole number combinations with double layer or single layer AC windings are obtained and validated by finite element (FE) analysis on four typical partitioned stator WFSMs (PS-WFSMs). A PS-WFSM prototype is built and tested to validate both analytical and FE analyses.