Joseph T. Hodges

Joseph T. Hodges

Auto-generated profile, based on publicly available information

Joseph T. Hodges

National Institute of Standards and Technology, Gaithersburg, MD 20899, USA

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2022 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
KBKatarzyna Bielska
Katarzyna Bielska
AKAleksandra A. Kyuberis
Aleksandra A. Kyuberis
ZRZachary D. Reed
Zachary D. Reed
GLGang Li
Gang Li
ACAgata Cygan
Agata Cygan
OPOleg L. Polyansky
Oleg L. Polyansky
Intensities of lines in the near-infrared second overtone band (3–0) of C12O16 are measured and calculated to an unprecedented degree of precision and accuracy. Agreement between theory and experiment to better than 1‰ is demonstrated by results from two laboratories involving two independent absorption- and dispersion-based cavity-enhanced techniques. Similarly, independent Fourier transform spectroscopy measurements of stronger lines in this band yield mutual agreement and consistency with theory at the 1‰ level. This set of highly accurate intensities can provide an intrinsic reference for reducing biases in future measurements of spectroscopic peak areas.

24 July 2019 in Physical Review Letters
Verified
Journal Article
Closed access
PDF file
AFAdam J. Fleisher
Adam J. Fleisher
EAErin M. Adkins
Erin M. Adkins
ZRZachary D. Reed
Zachary D. Reed
HYHongming Yi
Hongming Yi
DLDavid A. Long
David A. Long
JHJoseph T. Hodges
Joseph T. Hodges
To accurately attribute sources and sinks of molecules like CO2, remote sensing missions require line intensities (S) with relative uncertainties ur(S)<0.1%. However, discrepancies in S of ≈1% are common when comparing different experiments, thus limiting their potential impact. Here we report a cavity ring-down spectroscopy multi-instrument comparison which revealed that the hardware used to digitize analog ring-down signals caused variability in spectral integrals which yield S. Our refined approach improved measurement accuracy 25-fold, resulting in ur(S)=0.06%.

19 June 2007 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
DLD. Lisak
D. Lisak
JHJ.T. Hodges
J.T. Hodges


10 March 2020 in Geophysical Research Letters
Verified
Journal Article
Open access
PDF file
DLD. A. Long
D. A. Long
ZRZ. D. Reed
Z. D. Reed
AFA. J. Fleisher
A. J. Fleisher
JMJ. Mendonca
J. Mendonca
SRS. Roche
S. Roche
JHJ. T. Hodges
J. T. Hodges
Two cavity ring‐down spectrometers were employed to accurately measure line intensities in a series of near‐infrared carbon dioxide bands including (30012) ← (00001), (30013) ← (00001), and (30014) ← (00001) near 1.6 μm. Relative combined standard uncertainties for these band intensities were less than 0.1% and showed significant, percent‐level deviations with respect to many existing spectroscopic databases (although close agreement was observed with the HITRAN 2016 database in the (30013) ← (00001) and (30014) ← (00001) bands). Further, the resulting line intensities were utilized in Total Carbon Column Observing Network retrievals and led to significantly reduced biases in the (30012) ← (00001) and (30013) ← (00001) bands. These results indicate that refinements of spectroscopic databases are required to meet the accuracy targets of both ground‐ and satellite‐based remote sensing missions.

4 April 2019 in Metrologia
Verified
Journal Article
Open access
JHJ T Hodges
J T Hodges
JVJ Viallon
J Viallon
PBPaul Brewer
Paul Brewer
BDB J Drouin
B J Drouin
VGV Gorshelev
V Gorshelev
RWR I Wielgosz
R I Wielgosz