Adam J. Fleisher

Adam J. Fleisher

Auto-generated profile, based on publicly available information

Adam J. Fleisher

National Institute of Standards and Technology, Gaithersburg, USA

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2012 in Applied Physics B
Verified
Journal Article
Closed access
PDF file
AFAleksandra Foltynowicz
Aleksandra Foltynowicz
PMPiotr Maslowski
Piotr Maslowski
AFA. J. Fleisher
A. J. Fleisher
BBB. J. Bjork
B. J. Bjork
JYJ. Ye
J. Ye

16 June 2014 in The Journal of Physical Chemistry Letters
Verified
Journal Article
Closed access
AFAdam J. Fleisher
Adam J. Fleisher
BBBryce J. Bjork
Bryce J. Bjork
TBThinh Q. Bui
Thinh Q. Bui
KCKevin C. Cossel
Kevin C. Cossel
MOMitchio Okumura
Mitchio Okumura
JYJun Ye
Jun Ye

31 July 2012 in Optics Letters
Verified
Journal Article
Closed access
PDF file
LNLora Nugent-Glandorf
Lora Nugent-Glandorf
TNTyler Neely
Tyler Neely
FAFlorian Adler
Florian Adler
AFAdam J. Fleisher
Adam J. Fleisher
KCKevin Cossel
Kevin Cossel
SDScott A. Diddams
Scott A. Diddams
We present and characterize a two-dimensional (2D) imaging spectrometer based on a virtually imaged phased array (VIPA) disperser for rapid, high-resolution molecular detection using mid-infrared (MIR) frequency combs at 3.1 and 3.8 μm. We demonstrate detection of CH4 at 3.1 μm with >3750 resolution elements spanning >80  nm with ∼600  MHz resolution in a <10  μs acquisition time. In addition to broadband detection, we also demonstrate rapid, time-resolved single-image detection by capturing dynamic concentration changes of CH4 at a rate of ∼375 frames per second. Changes in absorption above the noise floor of 5×10−4 are readily detected on the millisecond time scale, leading to important future applications such as real-time monitoring of trace gas concentrations and detection of reactive intermediates.

4 May 2016 in Optics Express
Verified
Journal Article
Open access
PDF file
AFAdam J. Fleisher
Adam J. Fleisher
DLDavid A. Long
David A. Long
ZRZachary D. Reed
Zachary D. Reed
JHJoseph T. Hodges
Joseph T. Hodges
DPDavid F. Plusquellic
David F. Plusquellic
Dual-comb spectroscopy allows for the rapid, multiplexed acquisition of high-resolution spectra without the need for moving parts or low-resolution dispersive optics. This method of broadband spectroscopy is most often accomplished via tight phase locking of two mode-locked lasers or via sophisticated signal processing algorithms, and therefore, long integration times of phase coherent signals are difficult to achieve. Here we demonstrate an alternative approach to dual-comb spectroscopy using two phase modulator combs originating from a single continuous-wave laser capable of > 2 hours of coherent real-time averaging. The dual combs were generated by driving the phase modulators with step-recovery diodes where each comb consisted of > 250 teeth with 203 MHz spacing and spanned > 50 GHz region in the near-infrared. The step-recovery diodes are passive devices that provide low-phase-noise harmonics for efficient coupling into an enhancement cavity at picowatt optical powers. With this approach, we demonstrate the sensitivity to simultaneously monitor ambient levels of CO2, CO, HDO, and H2O in a single spectral region at a maximum acquisition rate of 150 kHz. Robust, compact, low-cost and widely tunable dual-comb systems could enable a network of distributed multiplexed optical sensors.

13 December 2016 in Physical Review A
Verified
Journal Article
Open access
PDF file
DLD. A. Long
D. A. Long
AFA. J. Fleisher
A. J. Fleisher
DPD. F. Plusquellic
D. F. Plusquellic
JHJ. T. Hodges
J. T. Hodges
An optical frequency comb generated with an electro-optic phase modulator and a chirped radio-frequency waveform is used to perform pump-probe spectroscopy on the D1 and D2 transitions of atomic potassium at 770.1 and 766.7 nm, respectively. With a comb tooth spacing of 200 kHz and an optical bandwidth of 2 GHz the hyperfine transitions can be observed simultaneously. Interferograms are recorded in as little as 5 µs (a timescale corresponding to the inverse of the comb tooth spacing). Importantly, the sub-Doppler features can be measured as long as the laser carrier frequency lies within the Doppler profile, thus removing the need for slow scanning or a priori knowledge of the frequencies of the sub-Doppler features. Sub-Doppler optical frequency comb spectroscopy has the potential to dramatically reduce acquisition times and allow for rapid and accurate assignment of complex molecular and atomic spectra which are presently intractable.

7 September 2017 in The Journal of Physical Chemistry Letters
Verified
Journal Article
Closed access
AFAdam J. Fleisher
Adam J. Fleisher
DLDavid A. Long
David A. Long
QLQingnan Liu
Qingnan Liu
LGLyn Gameson
Lyn Gameson
JHJoseph T. Hodges
Joseph T. Hodges