Min A. Yoon

Min A. Yoon

Auto-generated profile, based on publicly available information

Min A. Yoon

Department of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul, Korea

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2016 in Injury
Verified
Journal Article
Closed access
TLTae Hoon Lee
Tae Hoon Lee
KJKyu Sun Jang
Kyu Sun Jang
GCGi Won Choi
Gi Won Choi
CJChan Dong Jeong
Chan Dong Jeong
SHSuk-Joo Hong¹
Suk-Joo Hong¹
HKHaK-Jun Kim
HaK-Jun Kim

19 March 2021 in European Radiology
Verified
Journal Article
Closed access
PDF file
CCChoong Guen Chee
Choong Guen Chee
MYMin A Yoon
Min A Yoon
KKKyung Won Kim
Kyung Won Kim
YKYusun Ko
Yusun Ko
SHSu Jung Ham
Su Jung Ham
HCHye Won Chung
Hye Won Chung

1 November 2021 in British Journal of Radiology
Verified
Journal Article
Closed access
JKJunghoon Kim
Junghoon Kim
CCChoong Guen Chee
Choong Guen Chee
JCJungheum Cho
Jungheum Cho
YKYoungjune Kim
Youngjune Kim
MYMin A Yoon
Min A Yoon
Objectives: To determine the diagnostic accuracy and complication rate of percutaneous transthoracic needle biopsy (PTNB) for subsolid pulmonary nodules and sources of heterogeneity among reported results. Methods: We searched PubMed, EMBASE, and Cochrane libraries (until November 7, 2020) for studies measuring the diagnostic accuracy of PTNB for subsolid pulmonary nodules. Pooled sensitivity and specificity of PTNB were calculated using a bivariate random-effects model. Bivariate meta-regression analyses were performed to identify sources of heterogeneity. Pooled overall and major complication rates were calculated. Results: We included 744 biopsies from 685 patients (12 studies). The pooled sensitivity and specificity of PTNB for subsolid nodules were 90% (95% confidence interval [CI]: 85–94%) and 99% (95% CI: 92–100%), respectively. Mean age above 65 years was the only covariate significantly associated with higher sensitivity (93% vs 85%, p = 0.04). Core needle biopsy showed marginally higher sensitivity than fine-needle aspiration (93% vs 83%, p = 0.07). Pooled overall and major complication rate of PTNB were 43% (95% CI: 25–62%) and 0.1% (95% CI: 0–0.4%), respectively. Major complication rate was not different between fine-needle aspiration and core needle biopsy groups (p = 0.25). Conclusion: PTNB had acceptable performance and a low major complication rate in diagnosing subsolid pulmonary nodules. The only significant source of heterogeneity in reported sensitivities was a mean age above 65 years. Advances in knowledge: This is the first meta-analysis attempting to systemically determine the cause of heterogeneity in the diagnostic accuracy and complication rate of PTNB for subsolid pulmonary nodules.

25 April 2022 in Scientific Reports
Verified
Journal Article
Open access
PDF file
TPTaeyong Park
Taeyong Park
MYMin A Yoon
Min A Yoon
YCYoung Chul Cho
Young Chul Cho
SHSu Jung Ham
Su Jung Ham
YKYousun Ko
Yousun Ko
JLJeongjin Lee
Jeongjin Lee
Although CT radiomics has shown promising results in the evaluation of vertebral fractures, the need for manual segmentation of fractured vertebrae limited the routine clinical implementation of radiomics. Therefore, automated segmentation of fractured vertebrae is needed for successful clinical use of radiomics. In this study, we aimed to develop and validate an automated algorithm for segmentation of fractured vertebral bodies on CT, and to evaluate the applicability of the algorithm in a radiomics prediction model to differentiate benign and malignant fractures. A convolutional neural network was trained to perform automated segmentation of fractured vertebral bodies using 341 vertebrae with benign or malignant fractures from 158 patients, and was validated on independent test sets (internal test, 86 vertebrae [59 patients]; external test, 102 vertebrae [59 patients]). Then, a radiomics model predicting fracture malignancy on CT was constructed, and the prediction performance was compared between automated and human expert segmentations. The algorithm achieved good agreement with human expert segmentation at testing (Dice similarity coefficient, 0.93–0.94; cross-sectional area error, 2.66–2.97%; average surface distance, 0.40–0.54 mm). The radiomics model demonstrated good performance in the training set (AUC, 0.93). In the test sets, automated and human expert segmentations showed comparable prediction performances (AUC, internal test, 0.80 vs 0.87, p = 0.044; external test, 0.83 vs 0.80, p = 0.37). In summary, we developed and validated an automated segmentation algorithm that showed comparable performance to human expert segmentation in a CT radiomics model to predict fracture malignancy, which may enable more practical clinical utilization of radiomics.

1 June 2020 in European Journal of Radiology
Verified
Journal Article
Closed access
ESEun Jung Shim
Eun Jung Shim
MYMin A Yoon
Min A Yoon
HYHye Jin Yoo
Hye Jin Yoo
CCChoong Guen Chee
Choong Guen Chee
MLMin Hee Lee
Min Hee Lee
MSMyung Jin Shin
Myung Jin Shin

6 January 2022 in Academic Radiology
Verified
Journal Article
Closed access
AKA Yeon Kim
A Yeon Kim
MYMin A Yoon
Min A Yoon
SHSu Jung Ham
Su Jung Ham
YCYoung Chul Cho
Young Chul Cho
YKYousun Ko
Yousun Ko
HCHye Won Chung
Hye Won Chung