20 March 2023 in IEEE Transactions on Instrumentation and Measurement
Conductivity is an essential parameter for solid metal rods, which can be applied to assess quality. In this paper, an eddy current testing(ECT) method is investigate to measure the conductivity of solid metal rods. Above all, the simplified theoretical model is derived for a coil encircling a cylindrical sample. According to the proposed model, the real part of the coil impedance variation at high frequency (~ MHz) is closely related with the reciprocal of root of the rod conductivity. Therefore, a simple and effective conductivity measurement method for solid rod conductivity measurement is investigated based on the relationship between the impedance variation and the solid rod conductivity. Moreover, the effect of metal rods and coils parameters on the proposed method are also analyzed. Finally, the proposed method is verified with measurements of conductive materials. The results demonstrate the investigated simplified theoretical model is accurate and reasonable, and the relative error of the solid rod conductivity measurement is 2.2%.
3 February 2023 in IEEE Transactions on Instrumentation and Measurement
Electromagnetic coupling and lift-off variation are obstacles in the eddy current method. In this paper, we proposed a sweep frequency eddy current method to achieve conductivity and permeability simultaneous measurements immune to lift-off. The relationship between eddy current detection signals of different frequencies and electromagnetic parameters of magnetic materials has been found. That is, the real part of mutual inductance is mainly related to permeability at low frequency. In high frequency, the zero crossover-frequency is the proportional to the ratio of permeability and conductivity. By combining the analysis mentioned above, conductivity and permeability can be estimated simultaneously. In order to eliminate the interference of lift-off, a sensor structure with one excitation coil and two receiving coils is designed to compensate the mutual inductance changes caused by lift-off. Experiments and FEM simulations are also carried out to verify the proposed method. The results show the errors of conductivity and permeability are 1.3% and 3.9% respectively, and the error caused by reasonable variation range of lift-off can be significantly reduced.
29 October 2021 in IEEE Transactions on Instrumentation and Measurement
Gas–liquid intermittent flow commonly occurs in industrial processes such as oil well production, pipeline transportation, and nuclear reactor cooling. Investigation of Taylor bubble behavior in the intermittent flow is essential for safe operation and heat and mass transfer efficiency enhancement. Since the gas–liquid interface contains fluctuations, it is difficult to obtain high-resolution bubble surface with traditional measurement methods. In this article, a novel laser-induced fluorescence (LIF) based 3-D reconstruction and volume measurement method for Taylor bubble is developed. First, LIF technique is improved to not only detect the bubble section contour, but also measure the bubble velocity. In addition, to increase the axial spatial resolution of bubble section contour sequence, a volumetric image interpolation algorithm suitable for bubble morphology is developed. And the marching cubes algorithm is further introduced to reconstruct the Taylor bubble surface to achieve fine 3-D visualization. More importantly, the Monte Carlo method is combined with the reconstruction results to realize the volume measurement of irregularly shaped Taylor bubbles. Finally, the relationship between length and volume is established based on the measurement results, through which the volume of Taylor bubbles can be predicted by the easy-to-measure bubble length. The experimental results conclude that the reported volume measurement method for Taylor bubble is valid with high precision, and the numerical simulation data are also used to verify the effectiveness of the bubble volume prediction model.
20 January 2021 in IEEE Sensors Journal
Gas-liquid slug flow in horizontal pipes occurs frequently in industrial applications and is harmful to the piping systems owing to its intermittent structures. Therefore, it is essential to accurately describe the flow structure and investigate the flow mechanism. A non-intrusive fluorescence imaging method is employed to quantitatively reconstruct the slug bubble in a 15mm ID horizontal pipe in this article. Optical distortion correction method is firstly developed to improve the measurement accuracy of the instantaneous gas holdup, and then the time-average axial bubble velocity is simultaneously measured according to the feature matching of cross-sectional images. Additionally, the influence of phase superficial velocity on the interface stability is investigated through the phase holdup and the circumferential curvature distribution analysis. The typical three-dimensional structures of slug bubble are finally reconstructed through the velocity-based bicubic interpolation and median fusion algorithm. Previous correlations and reference instrumentation are used to evaluate the proposed method. Comparison results show that the method can effectively measure the flow parameters and reconstruct slug bubbles.
14 October 2026 in Journal of Cleaner Production