Optical carrier-based microwave interferometry (OCMI) has been widely concerned and studied due to its unique advantages in combining the strengths of optics and microwave. This paper theoretically and experimentally investigates the OCMI-based distributed measurement of temperature. The distributed temperature measurement is demonstrated experimentally using a single-mode fiber (SMF) with cascading weak optical reflectors inscribed along the fiber core, where any two reflectors are paired to define an intrinsic Fabry-Perot interferometer (IFPI). Spatially continuous distributed temperature demodulation is achieved by reconstructing the microwave interferogram of the IFPIs consisting of two adjacent reflectors. IFPIs with different cavity lengths consisting of two non-adjacent reflectors are also demodulated to study the temperature sensitivity at different spatial resolutions. Experimental results show that the IFPIs along the sensing fiber have a linear response to the temperature, especially the IFPI with the 30cm cavity length exhibits a better linear response, reversibility and stability in the temperature range of 35°C-75°C. Comparing with the experimental and theoretical values, this paper further theoretically investigates the effect of fiber coating layer on the temperature sensitivity of the sensing system, taking into account the physical and geometric properties of the fiber outer coating layer. In addition, a dual-path distributed temperature measurement based on spatial division multiplexing is demonstrated, validating the excellent multiplexing ability and application potential of the OCMI-based multi-path distributed measurement.
We propose a technique to achieve high-speed and high-precision distance measurement via phase demodulation of broadband optical carrier-based microwave interferometry (OCMI). An in-phase and quadrature (I/Q) processing scheme is designed and incorporated to measure the phase shift induced by target distance. The results could be efficiently derived from a minimum of one pair of detected outputs with immunity to power fluctuations. To extend the non-ambiguous measurement range while maintaining high resolution, a multifrequency-based phase unwrapping procedure is implemented. In the meantime, a driving module is utilized to effectively amplify and stabilize the signal. Experiments were carried out to evaluate the feasibility and performance of the proposed OCMI distance measurement method, which exhibits good accuracy, stability, and reliability. The maximum residual error is found to be 0.084 mm and the relative error is less than 2 × 10 −4 . Moreover, the method is capable to perform thousands of measurements within a few seconds, thus the OCMI-based dynamic target tracking has been achieved.
Gas–liquid intermittent flow commonly occurs in industrial processes such as oil well production, pipeline transportation, and nuclear reactor cooling. Investigation of Taylor bubble behavior in the intermittent flow is essential for safe operation and heat and mass transfer efficiency enhancement. Since the gas–liquid interface contains fluctuations, it is difficult to obtain high-resolution bubble surface with traditional measurement methods. In this article, a novel laser-induced fluorescence (LIF) based 3-D reconstruction and volume measurement method for Taylor bubble is developed. First, LIF technique is improved to not only detect the bubble section contour, but also measure the bubble velocity. In addition, to increase the axial spatial resolution of bubble section contour sequence, a volumetric image interpolation algorithm suitable for bubble morphology is developed. And the marching cubes algorithm is further introduced to reconstruct the Taylor bubble surface to achieve fine 3-D visualization. More importantly, the Monte Carlo method is combined with the reconstruction results to realize the volume measurement of irregularly shaped Taylor bubbles. Finally, the relationship between length and volume is established based on the measurement results, through which the volume of Taylor bubbles can be predicted by the easy-to-measure bubble length. The experimental results conclude that the reported volume measurement method for Taylor bubble is valid with high precision, and the numerical simulation data are also used to verify the effectiveness of the bubble volume prediction model.
The articulated laser sensor is a new kind of trans-scale and non-contact measurement instrument in regular-size space and industrial applications. These sensors overcome many deficiencies and application limitations of traditional measurement methods. The articulated laser sensor consists of two articulated laser sensing modules, and each module is made up of two rotary tables and one collimated laser. The three axes represent a non-orthogonal shaft architecture. The calibration method of system parameters for traditional instruments is no longer suitable. A novel high-accuracy calibration method of an articulated laser sensor for trans-scale 3D measurement is proposed. Based on perspective projection models and image processing techniques, the calibration method of the laser beam is the key innovative aspect of this study and is introduced in detail. The experimental results show that a maximum distance error of 0.05 mm was detected with the articulated laser sensor. We demonstrate that the proposed high-accuracy calibration method is feasible and effective, particularly for the calibration of laser beams.