Paulo R. D. R. Da Silva

Paulo R. D. R. Da Silva

Auto-generated profile, based on publicly available information

Paulo R. D. R. Da Silva

Universidade Estadual de Campinas (UNICAMP)

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 May 2024 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
José Antonio De la O SernaJosé Antonio De la O Serna
José Antonio De la O Serna
AZAlejandro Zamora-Mendez
Alejandro Zamora-Mendez
GMGabriel E. Mejia-Ruiz
Gabriel E. Mejia-Ruiz
MPMario Arrieta Paternina
Mario Arrieta Paternina
DDDaniel Dotta
Daniel Dotta
PSPaulo R. D. R. Silva
Paulo R. D. R. Silva
This paper proposes the FTFT for the real-time monitoring of modern power grids through dynamic harmonic estimations. The FTFT results from the DTTFT implemented with the FFT, instead of its filter bank implementation. In FTFT, the harmonic Taylor-Fourier coefficients are obtained in batch, and from these complex coefficients, estimates of frequency, amplitude, and RoCoF are obtained. The FTFT is embedded in two low-cost platforms, one consisting of a digital signal processor (DSP) coded using C programming language, and a development PMU (D-PMU); where a computationally efficient calculation of the FTFT is coded in both platforms. Both platforms process instantaneous voltage and current signals, rendering phasor and harmonic estimates as if they were extracted by the impulse response of a set of FIR filters and their first and second differentiators of the DTTFT. The phasor and harmonic estimations are accomplished using a sliding window that updates sample by sample, instantaneously providing amplitude, phase, frequency, and RoCoF estimations at the fundamental and harmonic frequencies with a high reporting rate. Experimental results confirm the proposition's performance, precision, and effectiveness under steady-state conditions, sudden changes, and harmonic analysis.

18 March 2025 in Eletrônica de Potência
Verified
Journal Article
Open access
PDF file
CCCaíque C. A. De Carvalho
Caíque C. A. De Carvalho
PSPaulo R. D. R. Da Silva
Paulo R. D. R. Da Silva
José Mario AraújoJosé Mario Araújo
José Mario Araújo
JPJOSE ANTENOR POMILIO
JOSE ANTENOR POMILIO
Leakage current is an issue that often causes problems in transformerless grid-connected PV inverters, such as electromagnetic interference, which is conducted or radiated and derates the quality of power injected into the grid. It can also lead to electrical safety problems, impair the performance of other equipment nearby, and thus make the generation system unavailable. Therefore, mitigation procedures for the leakage current in transformerless grid-connected PV inverters are essential to ensure system efficiency and safety. In this sense, a new single-phase grid-connected transformerless inverter topology was proposed using modulation switching techniques to keep the leakage current at acceptable standard levels. With the proposed topology, by monitoring the leakage current rms value, the inverter can be driven in a three- or five-level pattern for the main switches, thereby keeping the leakage current at a satisfactory level. The topology was implemented in a versatile hardware-in-loop Typhoon-HIL to emulate a digital twin of the complete system, with the control loops and switching generation embedded in a family Texas Instruments F28335 DSP. The results obtained for total harmonic distortion and energy conversion efficiency were then compared with other consolidated topologies, and the leakage current was proved to be effectively modified when the inverter is switched in three- or five-level modes.

1 June 2024
Verified
Book Chapter
Closed access
PDF file
ARAndrei Ribeiro
Andrei Ribeiro
RCRômullo Carvalho
Rômullo Carvalho
PSPaulo da Silva
Paulo da Silva
GLGeyciane Lima
Geyciane Lima
GPGuilherme Prym
Guilherme Prym
MVMarcelo Villalva
Marcelo Villalva