Madhusudan Mishra

Madhusudan Mishra

Auto-generated profile, based on publicly available information

Madhusudan Mishra

Centre of Excellence in Nano Science and Technology for development of Sensors, Berhampur University, Berhampur, India

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 February 2023 in IEEE Transactions on Nanobioscience
Verified
Journal Article
Closed access
AYArchana Yadav
Archana Yadav
AKAnil Kumar
Anil Kumar
PSPreeta Sharan
Preeta Sharan
MMMadhusudan Mishra
Madhusudan Mishra
The present study introduces a highly sensitive bimetallic SPR biosensor based on metal nitride for efficient urine glucose detection. Using a BK-7 prism, Au (25 nm), Ag (25nm), AlN (15 nm), and a biosample (urine) layer, the proposed sensor comprises of five layers. The selection of the sequence and dimensions of both metal layers is based on their performance in a number of case studies including both monometallic and bimetallic layers. After optimizing the bimetallic layer as Au (25 nm) – Ag (25 nm), various nitride layers were used to further increase the sensitivity by utilizing the synergistic effect of the bimetallic and metal nitride layers through case studies of several urine samples, ranging from nondiabetic to severely diabetic patients. AlN is determined to be the best suited material, and its thickness is optimized to 15 nanometers. The performance of the structure has been evaluated using a visible wavelength, i.e., λ = 633 nm, in order to increase sensitivity while providing room for low-cost prototyping. With the layer parameters optimized, a significant sensitivity of 411°/RIU (Refractive Index Unit) and figure of merit (FoM) of 105.38 /RIU has been achieved. The computed resolution of the proposed sensor is 4.17e-06. This study’s findings have also been compared to some recently reported results. The proposed structure would be useful for detecting glucose concentrations, with a rapid response as measured by a substantial shift in resonance angle in SPR curves.

15 July 2023 in Plasmonics
Verified
Journal Article
Closed access
PDF file
AYArchana Yadav
Archana Yadav
MMMadhusudan Mishra
Madhusudan Mishra
STSukanta K. Tripathy
Sukanta K. Tripathy
AKAnil Kumar
Anil Kumar
OSO. P. Singh
O. P. Singh
PSPreeta Sharan
Preeta Sharan

1 December 2021 in Physica Scripta
Verified
Journal Article
Closed access
MMMadhusudan Mishra
Madhusudan Mishra
NDNikhil R. Das
Nikhil R. Das
NSNarayan Sahoo
Narayan Sahoo
TSTrinath Sahu
Trinath Sahu
We study the electron transport in armchair graphene nanoribbon (AGNR) resonant tunneling diode (RTD) using square and V-shaped potential well profiles. We use non-equilibrium Green’s function formalism to analyze the transmission and I–V characteristics. Results show that an enhancement in the peak current ( I p ) can be obtained by reducing the well width ( W w ) or barrier width ( W b ). As W w decreases, I p shifts to a higher peak voltage ( V p ), while there is almost no change in V p with decreasing W b . It is gratifying to note that there is an enhancement in I p by about 1.6 times for a V -shaped well over a square well. Furthermore, in the case of a V -shaped well, the negative differential resistance occurs in a shorter voltage range, which may beneficial for ultra-fast switching and high-frequency signal generation. Our work anticipates the suitability of graphene having better design flexibility, to develop ideally 2D RTDs for use in ultra-dense nano-electronic circuits and systems.


4 August 2025 in Plasmonics
Verified
Journal Article
Closed access
PDF file
SSSandipta Senapati
Sandipta Senapati
AYArchana Yadav
Archana Yadav
MMMadhusudan Mishra
Madhusudan Mishra

9 October 2023 in IEEE Journal of Quantum Electronics
Verified
Journal Article
Closed access
SBSonali Basak
Sonali Basak
SSSantu Sarkar
Santu Sarkar
AMAbhijit K. Mukhopadhyay
Abhijit K. Mukhopadhyay
NDNikhil Ranjan Das
Nikhil Ranjan Das
MMMadhusudan Mishra
Madhusudan Mishra
In this paper, a new design of seven-core hole-assisted multi-core fiber with surrounding each core is presented. Here, the holes are assumed to be filled with materials having very low refractive index contrast with cladding. Coupling of light from the central core to the outer cores of seven-core structure is investigated by rotating the holes in the range +30° to -30° around the central core. The optimum range of angles for which coupling is very low is estimated for different values of core-pitch. An average value of crosstalk and power penalty are then calculated from the minimum coupling region for core pitch 40μm to 45μm where crosstalk goes below the threshold limit (which is taken as -30dB). An analytical model has also been developed based on proposed design and the results are seen to be in good agreement with the results from simulation. The proposed optimum design is extremely helpful for enhancing the capacity and efficiency of Space division multiplexing based applications with low crosstalk and power penalty.