20 February 2023 in IEEE Transactions on Nanobioscience
The present study introduces a highly sensitive bimetallic SPR biosensor based on metal nitride for efficient urine glucose detection. Using a BK-7 prism, Au (25 nm), Ag (25nm), AlN (15 nm), and a biosample (urine) layer, the proposed sensor comprises of five layers. The selection of the sequence and dimensions of both metal layers is based on their performance in a number of case studies including both monometallic and bimetallic layers. After optimizing the bimetallic layer as Au (25 nm) – Ag (25 nm), various nitride layers were used to further increase the sensitivity by utilizing the synergistic effect of the bimetallic and metal nitride layers through case studies of several urine samples, ranging from nondiabetic to severely diabetic patients. AlN is determined to be the best suited material, and its thickness is optimized to 15 nanometers. The performance of the structure has been evaluated using a visible wavelength, i.e., λ = 633 nm, in order to increase sensitivity while providing room for low-cost prototyping. With the layer parameters optimized, a significant sensitivity of 411°/RIU (Refractive Index Unit) and figure of merit (FoM) of 105.38 /RIU has been achieved. The computed resolution of the proposed sensor is 4.17e-06. This study’s findings have also been compared to some recently reported results. The proposed structure would be useful for detecting glucose concentrations, with a rapid response as measured by a substantial shift in resonance angle in SPR curves.
14 December 2021 in Journal of the Optical Society of America B
A novel, to the best of our knowledge, optimized structure is proposed to enhance the sensitivity of a surface plasmon resonance (SPR)-based biosensor for urine glucose detection by adding a few layers of black phosphorous (BP) (two-dimensional material) over the zinc oxide (ZnO) sandwiched in between gold (Au) and silver (Ag) bimetallic layers. Results show that with an optimized thickness of 42 nm/Au, 12 nm/ZnO, .05 nm/Ag, and 2.65 nm/BP, the sensitivity of 289°/RIU can be achieved at a 633 nm operating wavelength. This is enhanced up to 1.5 times from the conventional biosensor. It is further enhanced up to 3 times with the addition of five numbers of BP sheet layers (each sheet has a thickness of 0.53 nm) over the Au/ZnO/Ag layers, as BP possesses a high absorption coefficient at the incident wavelength of 633 nm. This biosensor is rather efficient at responding to the minute change of 0.001 in the refractive index of urine samples for non-diabetic persons (0–15 mg/dL) and diabetic persons (0.625 gm/dL, 1.25 gm/dL, 2.5 gm/dL, 5 gm/dL, and 10 gm/dL) with the corresponding refractive indices of 1.335, 1.336, 1.337, 1.338, 1.341, and 1.347. It provides significant resonance shift and higher sensitivity in terms of changes in the resonance angle shift. This proposed work has the potential to detect glucose concentration levels with higher accuracy and with faster sensor responses.
17 September 2021 in International Journal of Information Technology
12 July 2023 in IEEE Access
Advanced machine learning (ML) methods can predict student’s performance with key features based on academic, behavioral, and demographic data. Significant works have predicted the student’s performance based on the primary and secondary data sets derived from the student’s existing data. These works have accurately predicted student’s performance but did not provide the metrics as suggestions for improved performance. This paper proposes the ‘Learning Coefficients’ evaluated through trajectory-based computerized adaptive assessment. Learning coefficients also provide quantified metrics to the students to focus more on their studies and improve their further performance. Before selecting the learning coefficients as the key features for student’s performance prediction, their dependency on other key features is calculated through positive Pearson’s coefficient correlation. Further, the paper presents comparative analysis of the performance of regression-based ML models such as decision trees, random forest, support vector regression, linear regression and artificial neural networks on the same dataset. Results show that linear regression obtained the highest accuracy of 97% when compared to other models.
1 March 2024 in International Journal of Power Electronics and Drive Systems (IJPEDS)
The sub 100 µV voltage levels and sub 100 Hz frequency range makes the processing of most popular signal electroencephalograph (EEG) for brain functionality analysis, a complex task. The low frequency content of EEG (useful signals below 70 Hz) is commonly used for diagnosis of various brain related disorders making low-pass filter (LPF) a key block in front-end processing as noise reduction and resolution enhancement is crucial for precise recovery of these information. This paper is aimed to design reduced transconductance (Gm) based low power and small area CMOS LPF with cutoff frequency (fc) around 70 Hz. The proposed design is simulated using Cadence virtuoso tool and gives cut-off frequency of 72.958 Hz with low output noise of 3.0609 µV/√Hz and power consumption of 264.060 nW at operating voltage of 0.4 V. The simulation results show linearity of performance over -40 to 100 °C. Layout of circuit takes up area of 86.74×81.21 µm and post layout simulation shows 5% variation in power consumption as compared to pre layout simulations.