27 December 2017 in IEEE Transactions on Power Systems
As time delays of some remote signals cannot be ignored, the power system model must be represented as time-delay differential and algebraic equations. For this case, we can analyze the local dynamical characteristic of the system by calculating the eigenvalues of the related linearized system. In this paper, we present some practical tools to evaluate the impact of the delays on system modes. First, we derive an analytical method for computing the eigenvalue sensitivity. A Newton method for computing the exact eigenvalues of the time-delay system is then proposed, followed by an eigenvalue tracing method to obtain the eigenvalue trajectory when the delay varies. To realize the methods, a general linearized model and the generalized eigenvalue problem formulation are adopted. The proposed methods are applied to analyze the oscillation modes of two power systems with wide-area controllers.
25 November 2020 in IEEE Transactions on Power Systems
In this paper, the holomorphic embedding power flow method (HELM) is designed to solve the AC/DC hybrid power flow equations. According to the power flow model of the high voltage direct current systems (HVDC), an appropriate embedding technique with three recursive algorithms is developed for three different control modes, which is compatible with existing achievements of HELM for AC systems. In this method, the advantages of HELM, such as non-iterative, deterministic and non-ambiguous, are fully retained. In addition, a new calculation strategy based on Bauer's Eta algorithm is designed for the implementation of Pade approximations and the recursive process to avoid redundant calculations without reducing accuracy. In order to verify the reliability and effectiveness of the proposed extended HELM, several power flow cases with different scale are studied by HELM and traditional iterative method.
28 April 2021 in IEEE Transactions on Power Systems
Time delays are inevitable in load frequency control (LFC) of the power system, especially in a deregulated system where open communication networks are more favorable than the dedicated ones. However, extensive delays may affect the stability of a system. In this paper, an exact frequency-domain method for calculating the delay margin of LFC systems is presented, which is likely to be used to assess a system's stability caused by time-delays and guide the controller design. Firstly, a dynamic model of load frequency control systems is established, described by delay differential and algebraic equations (DDAEs). The Rekasius substitution is then employed to eliminate the transcendental terms in the characteristic equation without making any approximation. Afterward, an eigenvalue perturbation theory is introduced to transform the problem of calculating the delay margin into solving a series of one-dimensional nonlinear equations. Since only equivalent transforms are involved in the whole process, the delay margins obtained by the proposed method are exact. Finally, a two-area and a three-area deregulated LFC systems are applied to verify the correctness and efficiency of the proposed method.
1 November 2018 in IEEE Transactions on Power Systems
Applications of VSC-MTDC operation adjustments for damping inter-area oscillations are addressed and analyzed. The new operation adjustment method is proposed to meet short-term solution requirements and accommodate critical operation conditions where the conventional damping stabilizer by using active power modulation cannot provide sufficient damping. Based on the sensitivities with respect to the active power injections of VSCs and the interior point algorithm, an operation optimization method is presented to obtain a proper VSC-MTDC operation scheme to achieve better damping performance for an AC/VSC-MTDC system. For some critical operation conditions in which an inter-area oscillation has been detected, an operation rescheduling method is proposed as an emergency oscillation control. Time-domain simulations are performed on a New England system with a five-terminal MTDC grid. A comparative study with a conventional damping stabilizer is also included in the case study. Both the theoretical analysis and the time-domain simulations have verified the effectiveness and superiority of the two proposed methods.
23 January 2017 in IEEE Transactions on Smart Grid
As a power system operating point alters its position due to variations in power injections, its small-signal stability margin (SSSM) may decrease. Under this situation, a network topology change via line switching can increase the SSSM. In this paper, an online line switching method for maximizing the SSSM is presented, taking into account both the solution quality and the required computational speed. To balance the tradeoff between speed and solution quality, the line switching method presented in this paper is composed of three stages: 1) screening; 2) ranking; and 3) detailed evaluation. The effectiveness of the presented three-stage method is evaluated on IEEE standard power systems with promising results.
12 May 2011 in IEEE Transactions on Power Systems
This paper describes inexact two-sided Jacobi- Davidson (ITSJD) method to compute the critical (least damping ratio) eigenvalues and corresponding left and right eigenvectors of power systems. Using approximation correction vectors to expand search spaces of two-sided Jacobi-Davidson method leads to ITSJD, which is used to compute eigenvalues closest to the target. Only one LU factorization is needed in whole iteration to improve the computing efficiency. The critical eigenvalues are mapped to extreme eigenvalues of Cayley transformation matrix which can be calculated by using ITSJD. The proposed method has been tested on systems with orders of 493, 1461, and 3781. The results show that ITSJD is effective and able to compute the critical eigenvalues and eigenvectors.